摘要
This paper describes the development of a computational model to calculate wear rates in total shoulder prostheses, for a 5-150 degrees arm abduction. Anatomical keeled and pegged prosthesis as well as reversed prosthesis were the studied implants. The bone models were built based on computed tomography (CT) images and using a computer aided design-based modelling pipeline. The finite element method was used to solve the contact problem between the surface of the polyethylene (PE) components and the corresponding articular component. The aim of this work was to determine linear and volumetric PE wear, for several radial mismatches, in conditions of pathological (rheumatoid arthritis) and non-pathological bone. Results showed that contact pressures and linear wear developed in anatomical prosthesis were higher than those visualised in reversed prosthesis. However, anatomical prosthesis exhibited a better volumetric wear performance. Moreover, our findings indicated higher values of volumetric wear in higher congruent models and on pathological bone conditions.
引用
收藏
页码:883 / 892
页数:10
相关论文
共 50 条
  • [21] Pain and function in eight hundred and fifty nine patients comparing shoulder hemiprostheses, resurfacing prostheses, reversed total and conventional total prostheses
    Fevang, Bjorg-Tilde S.
    Lygre, Stein H. L.
    Bertelsen, Glenn
    Skredderstuen, Arne
    Havelin, Leif I.
    Furnes, Ove
    INTERNATIONAL ORTHOPAEDICS, 2013, 37 (01) : 59 - 66
  • [22] Pain and function in eight hundred and fifty nine patients comparing shoulder hemiprostheses, resurfacing prostheses, reversed total and conventional total prostheses
    Bjørg-Tilde S. Fevang
    Stein H. L. Lygre
    Glenn Bertelsen
    Arne Skredderstuen
    Leif I. Havelin
    Ove Furnes
    International Orthopaedics, 2013, 37 : 59 - 66
  • [23] BIOMECHANICAL ANALYSIS OF STABILITY AND FIXATION STRENGTH OF TOTAL SHOULDER PROSTHESES
    FUKUDA, K
    CHEN, CM
    COFIELD, RH
    CHAO, EYS
    ORTHOPEDICS, 1988, 11 (01) : 141 - 149
  • [24] Stress analysis of cemented glenoid prostheses in Total Shoulder Arthroplasty
    Gupta, S
    van der Helm, FCT
    van Keulen, F
    JOURNAL OF BIOMECHANICS, 2004, 37 (11) : 1777 - 1786
  • [25] Wear of knee prostheses
    Brockett, Claire L.
    Jennings, Louise M.
    Fisher, John
    ORTHOPEDIC RESEARCH AND REVIEWS, 2012, 4 : 19 - 26
  • [26] Complications of unconstrained shoulder prostheses
    Gonzalez, Jean-Francois
    Alami, Ghassan B.
    Baque, Francois
    Walch, Gilles
    Boileau, Pascal
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2011, 20 (04) : 666 - 682
  • [27] THE RADIOLOGY OF TOTAL SHOULDER PROSTHESES
    FELDMAN, F
    SEMINARS IN ROENTGENOLOGY, 1986, 21 (01) : 47 - 65
  • [28] UNCONSTRAINED TOTAL SHOULDER PROSTHESES
    COFIELD, RH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1983, (173) : 97 - 108
  • [29] ISOELASTIC PROSTHESES FOR SHOULDER JOINT
    BURRI, C
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1977, 345 : 601 - 601
  • [30] CONSTRUCTION OF SHOULDER AND BREAST PROSTHESES
    KNIGHT, NK
    SETZLER, DM
    SABELLA, SR
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 1975, 29 (04): : 209 - 212