摘要
Functionally Graded Materials (FGM) are extensively employed for hip plant component material due to their certain properties in a specific design to achieve the requirements of the hip-joint system. Nevertheless, if there are similar properties, it doesn't necessarily indicate that the knee plant is efficiently and effectively working. Therefore, it is important to develop an ideal design of functionally graded material femoral components that can be used for a long period. A new ideal design of femoral prosthesis can be introduced using functionally graded fiber polymer (FGFP) which will reduce the stress shielding and the corresponding stresses present over the interface. Herein, modal analysis of the complete hip plant part is carried out, which is the main factor and to date, very few research studies have been found on it. Moreover, this enhances the life of hip replacement, and the modal, harmonic, and fatigue analysis determines the pre-loading failure phenomena due to the vibrational response of the hip. This study deals with the cementless hip plant applying the finite element analysis (FEA) model in which geometry is studied, and the femoral bone model is based in a 3D scan.
引用
收藏
页码:129 / 146
页数:18
相关论文
共 50 条
  • [41] Optimum weight design of functionally graded material gears
    Shikai Jing
    He Zhang
    Jingtao Zhou
    Guohua Song
    Chinese Journal of Mechanical Engineering, 2015, 28 : 1186 - 1193
  • [42] Optimum Weight Design of Functionally Graded Material Gears
    JING Shikai
    ZHANG He
    ZHOU Jingtao
    SONG Guohua
    Chinese Journal of Mechanical Engineering, 2015, 28 (06) : 1186 - 1193
  • [43] Optimum Weight Design of Functionally Graded Material Gears
    Jing Shikai
    Zhang He
    Zhou Jingtao
    Song Guohua
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2015, 28 (06) : 1186 - 1193
  • [44] (BIOSTATISTICAL ANALYSIS OF WEIGHTBEARING AT HIP-JOINT) .1.
    ROESLER, H
    HAMACHER, P
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1972, 110 (01): : 67 - &
  • [45] Optimisation of material composition in functionally graded plates for thermal stress relaxation using statistical design support system
    Chiba, Ryoichi
    Sugano, Yoshihiro
    CURVED AND LAYERED STRUCTURES, 2024, 11 (01)
  • [46] Design optimization of cementless femoral hip prostheses using finite element analysis
    Kowalczyk, P
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (05): : 396 - 402
  • [47] FUNCTIONALLY GRADED MATERIAL DESIGN FOR PLANE STRESS STRUCTURES USING PHASE FIELD METHOD
    Alaimo, Gianluca
    Carraturo, Massimo
    Rocca, Elisabetta
    Reali, Alessandro
    Auricchio, Ferdinando
    SECOND INTERNATIONAL CONFERENCE ON SIMULATION FOR ADDITIVE MANUFACTURING (SIM-AM 2019), 2019, : 162 - 173
  • [48] WAGNER CUP PROTHESIS FOR HIP-JOINT (DBGM - GERMAN REGISTERED DESIGN)
    WAGNER, H
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1976, 342 : 614 - 614
  • [49] QUANTITATIVE-ANALYSIS OF THE GROWTH OF THE HIP-JOINT - A RADIOLOGICAL STUDY
    MESZAROS, T
    KERY, L
    ACTA ORTHOPAEDICA SCANDINAVICA, 1980, 51 (02): : 275 - 283
  • [50] PREPARATION OF HIP-JOINT ENDOPROSTHESES FOR QUALITATIVE AND QUANTITATIVE MORPHOLOGICAL ANALYSIS
    HAHN, M
    DONATH, K
    DELLING, G