Design and analysis of cementless hip-joint system using functionally graded material

被引:2
|
作者
Asiri, Saeed [1 ]
机构
[1] Engn Coll King Abdulaziz Univ, Mech Engn Dept, Jeddah, Saudi Arabia
关键词
functionally graded material; cementless hip-joint system; natural frequency; harmonic response; fatigue analysis; finite element analysis; modal analysis; MATERIAL SELECTION; PRODUCT DESIGN; BEHAVIOR; COMPONENT; IMPLANT;
D O I
10.24425/ame.2021.139804
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Functionally Graded Materials (FGM) are extensively employed for hip plant component material due to their certain properties in a specific design to achieve the requirements of the hip-joint system. Nevertheless, if there are similar properties, it doesn't necessarily indicate that the knee plant is efficiently and effectively working. Therefore, it is important to develop an ideal design of functionally graded material femoral components that can be used for a long period. A new ideal design of femoral prosthesis can be introduced using functionally graded fiber polymer (FGFP) which will reduce the stress shielding and the corresponding stresses present over the interface. Herein, modal analysis of the complete hip plant part is carried out, which is the main factor and to date, very few research studies have been found on it. Moreover, this enhances the life of hip replacement, and the modal, harmonic, and fatigue analysis determines the pre-loading failure phenomena due to the vibrational response of the hip. This study deals with the cementless hip plant applying the finite element analysis (FEA) model in which geometry is studied, and the femoral bone model is based in a 3D scan.
引用
收藏
页码:129 / 146
页数:18
相关论文
共 50 条
  • [31] SHAFT FISSURES DUE TO IMPLANTATION OF CEMENTLESS TOTAL ENDOPROSTHESES OF THE HIP-JOINT - AN EXPERIMENTAL-STUDY
    JANTSCH, S
    LEIXNERING, M
    SCHWAGERL, W
    HACKL, H
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1988, 107 (04) : 236 - 241
  • [32] THE HUMAN HIP-JOINT CAPSULAR-LIGAMENT SYSTEM
    SCHMIDT, HM
    GAMS, W
    ANATOMISCHER ANZEIGER, 1987, 163 (02): : 184 - 185
  • [33] Structural analysis of functionally graded material using sigmioadal and power law
    Abdali N.K.
    Madeh A.R.
    Diagnostyka, 2021, 22 (04): : 59 - 65
  • [34] ANALYSIS OF FUNCTIONALLY GRADED MATERIAL ACTUATOR USING NEW FINITE ELEMENTS
    Paulech, Juraj
    Murin, Justin
    Kutis, Vladimir
    Galik, Gabriel
    Sedlar, Tibor
    VIII INTERNATIONAL CONFERENCE ON COMPUTATIONAL METHODS FOR COUPLED PROBLEMS IN SCIENCE AND ENGINEERING (COUPLED PROBLEMS 2019), 2019, : 413 - 421
  • [35] The effect of constrained hip-joint design on crash dummy responses
    Tang, Liang
    Wang, Yuanbo
    Zhou, Qing
    INTERNATIONAL JOURNAL OF CRASHWORTHINESS, 2010, 15 (04) : 369 - 376
  • [36] COMMENTS ON THE BIOSTATICAL ANALYSIS OF THE HIP-JOINT .2.
    LEGAL, H
    REINECKE, M
    RUDER, H
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1978, 116 (06): : 889 - 896
  • [37] A CONTRIBUTION TO THE BIOSTATIC ANALYSIS OF THE HIP-JOINT .3.
    LEGAL, H
    REINECKE, M
    RUDER, H
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1980, 118 (05): : 804 - 815
  • [38] GAIT ANALYSIS AFTER PROSTHETIC REPLACEMENT OF HIP-JOINT
    BAON, L
    HIRSCH, C
    KENWRIGH.J
    PHYSICS IN MEDICINE AND BIOLOGY, 1972, 17 (05): : 741 - &
  • [39] COMPARATIVE FATIGUE DAMAGE ANALYSIS OF HIP-JOINT PROSTHESES
    PRATI, E
    FREDDI, A
    RANIERI, L
    TONI, A
    JOURNAL OF BIOMECHANICS, 1982, 15 (10) : 808 - 808
  • [40] Optimum Weight Design of Functionally Graded Material Gears
    JING Shikai
    ZHANG He
    ZHOU Jingtao
    SONG Guohua
    Chinese Journal of Mechanical Engineering, 2015, (06) : 1186 - 1193