Mitigation of Magnetic Flux Density of Underground Power Cable and its Conductor Temperature Based on FEM

被引:6
|
作者
Mohamed, Adel Zein El Dein [1 ]
Zaini, Hatim Ghazi [2 ]
Gouda, Osama E. [3 ]
Ghoneim, Sherif S. M. [4 ]
机构
[1] Aswan Univ, Fac Energy Engn, Aswan 81528, Egypt
[2] Taif Univ, Coll Comp & Informat Technol, Dept Comp Engn, Al Hawiyah 26571, Taif, Saudi Arabia
[3] Cairo Univ, Fac Engn, Dept Elect Power, Giza 12613, Egypt
[4] Taif Univ, Coll Engn, Dept Elect Engn, At Taif 21944, Saudi Arabia
关键词
Cable shielding; Power cables; Temperature; Magnetic flux density; Magnetic fields; Magnetic shielding; Steel; Underground cables; de-rating factor; magnetic flux density; magnetic shielding factor; mitigating shielding factor of temperature; shielding plate; FIELD;
D O I
10.1109/ACCESS.2021.3121175
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article proposes using a metallic plate to be installed above the underground power cable route to mitigate the maximum cable conductor temperature and the ground surface magnetic flux density surrounding the cable route and underground cable de-rating factor. The article presents a case study containing a single-circuit 145 kV, three-phase individual cables in flat formation. The impacts of the mitigation plate dimensions such as plate width, thickness, the distance between the underground cables and the plate used in the mitigation, and the plate material are investigated. Three kinds of materials are examined in this article, namely aluminum, steel 100, and steel 500. Moreover, the optimal design dimensions of the metallic plate for the case under study were estimated. It is concluded that the shielding factors of the magnetic flux density and cable core temperature with aluminum are greater than steel 100 and steel 500. In addition, the de-rating factor, which is the ratio of the current capacity of the underground cable with shielding plate and that without shielding plate at the same cable core temperature, is increased to be 1.28 with the use of shielding Aluminum plate, rather than 1.18 and 1.17 in case of using Steel 500 and Steel 100 shielding plates, respectively. Finally, the proposed algorithm was validated by comparing its results with the experimental measurements obtained by the others, indicating good agreements.
引用
收藏
页码:146592 / 146602
页数:11
相关论文
共 50 条
  • [31] EFFECT OF CONDUCTOR ELECTRON DENSITY OF A SUPERCONDUCTOR ON ITS TRANSITION TEMPERATURE
    KESSEL, W
    ZEITSCHRIFT FUR NATURFORSCHUNG PART A-ASTROPHYSIK PHYSIK UND PHYSIKALISCHE CHEMIE, 1969, A 24 (02): : 294 - &
  • [32] Evolution of Temperature Field around Underground Power Cable for Static and Cyclic Heating
    Ahmad, Shahbaz
    Rizvi, Zarghaam Haider
    Arp, Joan Chetam Christine
    Wuttke, Frank
    Tirth, Vineet
    Islam, Saiful
    ENERGIES, 2021, 14 (23)
  • [33] FEM/BEM Hybrid Method for Magnetic Field Evaluation Due to Underground Power Cables
    Machado, Vitor Malo
    IEEE TRANSACTIONS ON MAGNETICS, 2010, 46 (08) : 2876 - 2879
  • [34] Series Impedance and Losses of Magnetic Field Mitigation Plates for Underground Power Cables
    Gomes, Neuza
    Almeida, Maria Eduarda
    Machado, Vitor Malo
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2018, 60 (06) : 1761 - 1768
  • [35] Mitigation of the magnetic field due to underground power cables using an optimized grid
    Almeida, M. E.
    Malo Machado, V.
    Guerreiro das Neves, M.
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2011, 21 (01): : 180 - 187
  • [36] Calculation of earthing and screening effects of compensation conductor laid alongside underground multi-cable power lines
    Medic, I
    Majstrovic, M
    Sarajcev, P
    ELECTRICAL ENGINEERING AND ELECTROMAGNETICS VI, 2003, 5 : 205 - 214
  • [37] The magnetic field of underground 330 kV cable line and ways for its reduction
    Shcherba A.A.
    Podoltsev A.D.
    Kucheriava I.M.
    Technical Electrodynamics, 2019, 2019 (05): : 3 - 9
  • [38] Comparison of Conductor-Temperature Calculations Based on Different Radial-Position-Temperature Detections for High-Voltage Power Cable
    Yang, Lin
    Qiu, Weihao
    Huang, Jichao
    Hao, Yanpeng
    Fu, Mingli
    Hou, Shuai
    Li, Licheng
    ENERGIES, 2018, 11 (01):
  • [39] Decomposition of magnetic field intensity in ferrite based on time derivative of magnetic flux density and power loss
    Saotome H.
    Washizu T.
    Journal of the Magnetics Society of Japan, 2020, 44 (04): : 102 - 107
  • [40] Mitigation of conductor line galloping by a direct cable-connection to non-conductive composite power pylons
    Kliem, Mathias
    Johansen, Daniel
    Hogsberg, Jan
    JOURNAL OF VIBROENGINEERING, 2018, 20 (06) : 2268 - 2288