Mitigation of Magnetic Flux Density of Underground Power Cable and its Conductor Temperature Based on FEM

被引:6
|
作者
Mohamed, Adel Zein El Dein [1 ]
Zaini, Hatim Ghazi [2 ]
Gouda, Osama E. [3 ]
Ghoneim, Sherif S. M. [4 ]
机构
[1] Aswan Univ, Fac Energy Engn, Aswan 81528, Egypt
[2] Taif Univ, Coll Comp & Informat Technol, Dept Comp Engn, Al Hawiyah 26571, Taif, Saudi Arabia
[3] Cairo Univ, Fac Engn, Dept Elect Power, Giza 12613, Egypt
[4] Taif Univ, Coll Engn, Dept Elect Engn, At Taif 21944, Saudi Arabia
关键词
Cable shielding; Power cables; Temperature; Magnetic flux density; Magnetic fields; Magnetic shielding; Steel; Underground cables; de-rating factor; magnetic flux density; magnetic shielding factor; mitigating shielding factor of temperature; shielding plate; FIELD;
D O I
10.1109/ACCESS.2021.3121175
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article proposes using a metallic plate to be installed above the underground power cable route to mitigate the maximum cable conductor temperature and the ground surface magnetic flux density surrounding the cable route and underground cable de-rating factor. The article presents a case study containing a single-circuit 145 kV, three-phase individual cables in flat formation. The impacts of the mitigation plate dimensions such as plate width, thickness, the distance between the underground cables and the plate used in the mitigation, and the plate material are investigated. Three kinds of materials are examined in this article, namely aluminum, steel 100, and steel 500. Moreover, the optimal design dimensions of the metallic plate for the case under study were estimated. It is concluded that the shielding factors of the magnetic flux density and cable core temperature with aluminum are greater than steel 100 and steel 500. In addition, the de-rating factor, which is the ratio of the current capacity of the underground cable with shielding plate and that without shielding plate at the same cable core temperature, is increased to be 1.28 with the use of shielding Aluminum plate, rather than 1.18 and 1.17 in case of using Steel 500 and Steel 100 shielding plates, respectively. Finally, the proposed algorithm was validated by comparing its results with the experimental measurements obtained by the others, indicating good agreements.
引用
收藏
页码:146592 / 146602
页数:11
相关论文
共 50 条
  • [21] Sheath current characteristic and its reduction on underground power cable systems
    Jung, CK
    Lee, JB
    Kang, JW
    Wang, XH
    Song, YH
    2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 2562 - 2569
  • [22] Requirements for power line magnetic field mitigation using a passive loop conductor
    Yamazaki, K
    Kawamoto, T
    Fujinami, H
    IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (02) : 646 - 651
  • [23] Requirements for power line magnetic field mitigation using a passive loop conductor
    Yamazaki, K
    Kawamoto, T
    Fujinami, H
    2000 IEEE POWER ENGINEERING SOCIETY SUMMER MEETING, CONFERENCE PROCEEDINGS, VOLS 1-4, 2000, : 2539 - 2539
  • [24] Underground Power Cable Detection and Inspection Technology Based on Magnetic Field Sensing at Ground Surface Level
    Sun, Xu
    Lee, Wing Kin
    Hou, Yunhe
    Pong, Philip W. T.
    IEEE TRANSACTIONS ON MAGNETICS, 2014, 50 (07)
  • [25] Adaptive FEM-BPNN model for predicting underground cable temperature considering varied soil composition
    Al-Dulaimi, Abdullah Ahmed
    Guneser, Muhammet Tahir
    Hameed, Alaa Ali
    Marquez, Fausto Pedro Garcia
    Gouda, Osama E.
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2024, 51
  • [26] Assessment of underground cable ratings based on distributed temperature sensing
    Li, H. J.
    Tan, K. C.
    Su, Qi
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (04) : 1763 - 1769
  • [27] Simulation of Underground Cable Temperature Distribution Based on Multiphysics Modeling
    Yang, Yanfei
    Wang, Qi
    Liu, Zhenxing
    2021 11TH INTERNATIONAL CONFERENCE ON POWER, ENERGY AND ELECTRICAL ENGINEERING (CPEEE 2021), 2021, : 26 - 31
  • [28] The Effectiveness of Compensated Passive Loops for Mitigating Underground Power Cable Magnetic Fields
    del Pino Lopez, Juan Carlos
    Cruz Romero, Pedro
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (02) : 674 - 683
  • [29] A Theoretical Investigation of the Influence of Underground Power Cable Parameters on Magnetic Field Levels
    Rostovskiy, Ivan
    Okun, Oleksandr
    Shevchenko, Sergii
    Korpinen, Leena
    PIERS 2013 STOCKHOLM: PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM, 2013, : 1105 - 1108
  • [30] Concentric Neutrals Corrosion Localization and Its Impedance Analysis in the Underground Power Cable System Based on the Reflectometry
    Lee, Chun Ku
    Kwak, Ki Seok
    Park, Jin Bae
    Yoon, Tae Sung
    2012 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2012, : 1148 - 1153