Static and Cyclic Tension Behavior of Post-Installed Rebar after Exposure to High Temperature

被引:1
|
作者
Xie, Qun [1 ]
Xue, Song [1 ]
Zhao, Yongqiang [2 ]
机构
[1] Univ Jinan, Sch Civil Engn & Architecture, Jinan 250022, Peoples R China
[2] Liuzhou Inst Architecture & Design, Liuzhou 545000, Peoples R China
关键词
Cyclic loading; High temperature; Embedment depth; Cement-based adhesive; Bond stress distribution; BOND PERFORMANCE; ANCHORS; CONCRETE; STRENGTH; COMPOSITES; FAILURE; BARS; LOAD;
D O I
10.1007/s12205-020-0244-6
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to investigate the static and cyclic tension behavior of post-installed rebar along with cement-based adhesive that is adopted after exposure to high temperature, a three-phase experimental program has been carried out and two typical embedment depths, 10d and 15d are designed. The surfaces of specimens are firstly heated up to 800 degrees C, and then the residual strength at different temperatures of cement-based adhesive has been studied by consequent static pull-out tests. Experimental results show that the tensile strength has a significant reduction at elevated temperatures compared with that of room temperature. The cement-based adhesive has almost lost its full bond strength when the temperature exceeds 350 degrees C. Finally, the bond performance of cement-based adhesive under cyclic loading has been further tested and analyzed. It is found that both 10d and 15d specimens have failed abruptly with rebar pull-out. The employment of long embedment depth has been verified to be an effective method to improve the bond performance of cement-based adhesive under static and cyclic loading. Static numerical investigation indicates that the bond stress distribution is not uniform along the embedment length of post-installed rebar at different temperatures of cement-based adhesive. The temperature-dependent tensile strength prediction has also been obtained based on the experimental data.
引用
收藏
页码:1775 / 1786
页数:12
相关论文
共 50 条
  • [21] Behavior of Post-Installed Fastening under Seismic Action
    Muciaccia, Giovanni
    ACI STRUCTURAL JOURNAL, 2017, 114 (01) : 75 - 86
  • [22] Behavior of Post-Installed Bonded Bars as Shear Reinforcement
    Fiset, Mathieu
    Villemure, Felix-Antoine
    Bastien, Josee
    Mitchell, Denis
    ACI STRUCTURAL JOURNAL, 2020, 117 (04) : 159 - 168
  • [23] Experimental Study of Bonding Performance of Post-installed Rebar Anchors under Unilateral Pressure
    Zhao, Ning-yu
    Yang, Ailin
    Liu, Hao
    Song, Yi
    Jiang, Haifei
    JOURNAL OF ADVANCED CONCRETE TECHNOLOGY, 2024, 22 (01) : 47 - 61
  • [24] Influence of position of post-installed rebar and other factors on tensile performance of APC connector
    Yu Q.
    Tang Z.
    Zhang X.
    Fan B.
    Zhang Z.
    Chen Z.
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2022, 54 (10): : 84 - 99
  • [25] Impact of position of post-installed rebar and other factors on tensile performance of typeⅡ APC connector
    Yu, Qiong
    Chen, Jinsong
    Tang, Ziming
    Guo, Lin
    Xie, Qinghai
    Zhang, Zhi
    Chen, Zhenhai
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2024, 56 (10): : 101 - 114
  • [26] Cast-in and post-installed rebar anchorage systems in RC column foundation joints: Experimental investigations
    Mahadik, Vinay
    Sharma, Akanshu
    Hofmann, Jan
    Engineering Structures, 2021, 238
  • [27] Tightening Torque Influence on Pullout Behavior of Post-installed Expansion Anchors
    Delhomme, Fabien
    Pallud, Bertrand
    Rouane, Nicolas
    KSCE JOURNAL OF CIVIL ENGINEERING, 2018, 22 (10) : 3931 - 3939
  • [28] Tightening Torque Influence on Pullout Behavior of Post-installed Expansion Anchors
    Fabien Delhomme
    Bertrand Pallud
    Nicolas Rouane
    KSCE Journal of Civil Engineering, 2018, 22 : 3931 - 3939
  • [29] Cast-in and post-installed rebar anchorage systems in RC column foundation joints: Experimental investigations
    Mahadik, Vinay
    Sharma, Akanshu
    Hofmann, Jan
    ENGINEERING STRUCTURES, 2021, 238
  • [30] Behavior of post-installed large-diameter anchors in concrete foundations
    Wang, Dongpo
    Wu, Dongsheng
    He, Siming
    Zhou, Jun
    Ouyang, Chaojun
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 95 : 124 - 132