Tightening Torque Influence on Pullout Behavior of Post-installed Expansion Anchors

被引:0
|
作者
Fabien Delhomme
Bertrand Pallud
Nicolas Rouane
机构
[1] University of Lyon,
[2] INSA-Lyon,undefined
[3] GEOMAS,undefined
[4] Hilti France,undefined
来源
关键词
anchor; pullout test; creep; concrete; prestress;
D O I
暂无
中图分类号
学科分类号
摘要
Post-installed anchors in reinforced concrete structures are increasingly important in current constructions especially in repair or upgrading works. A research program was completed to determine the influence of the tightening torque and the anchorage depth on the pullout performances of torque-controlled expansion anchors. The diameter d of the tested anchors was 10 mm. Six configurations were tested on 18 concrete blocks. Three pre-tension loads and two anchorage depths were considered. The results show that the fastening torque has no influence on the load-bearing capacity far away from the edges. However, an increase of the torque leads to a decrease of the anchor’s slipping during pullout tests. Nevertheless, applying an excessive fastening torque may lead to a steel-rupture of the anchor during the fastening phase. An increase of the anchorage depth leads to a better load capacity of the anchor and reduces the risk of concrete cone rupture. Finally, a simplified model of the tension response of the anchor with a bilinear load-displacement relationship has been suggested.
引用
收藏
页码:3931 / 3939
页数:8
相关论文
共 50 条
  • [1] Tightening Torque Influence on Pullout Behavior of Post-installed Expansion Anchors
    Delhomme, Fabien
    Pallud, Bertrand
    Rouane, Nicolas
    [J]. KSCE JOURNAL OF CIVIL ENGINEERING, 2018, 22 (10) : 3931 - 3939
  • [2] Post-installed anchors in concrete strengthened by post-installed reinforcement under tensile load
    Siamakani, Seyed Yaser Mousavi
    Sahamitmongkol, Raktipong
    [J]. EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2022, 26 (13) : 6563 - 6582
  • [3] Fire Rating of Post-Installed Anchors and Rebars
    Mahrenholtz, Philipp
    Sharma, Akanshu
    [J]. CIVILENG, 2020, 1 (03): : 216 - 228
  • [4] Behavior of post-installed large-diameter anchors in concrete foundations
    Wang, Dongpo
    Wu, Dongsheng
    He, Siming
    Zhou, Jun
    Ouyang, Chaojun
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2015, 95 : 124 - 132
  • [5] Shear Behavior and Design of Post-Installed Anchors in Thin Concrete Members
    Tarawneh, Ahmad N.
    Ross, Brandon E.
    Cousins, Thomas E.
    [J]. ACI STRUCTURAL JOURNAL, 2020, 117 (03) : 311 - 322
  • [6] Pullout Tests on Post-installed Bonded Anchors in Ultra-high Performance Fiber Reinforced Concrete
    Delhomme, Fabien
    Brun, Michael
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2019, 29 (03) : 417 - 424
  • [7] Behavior of Post-Installed Anchors Tested by Stepwise Increasing Cyclic Crack Protocols
    Mahrenholtz, Christoph
    Eligehausen, Rolf
    Hutchinson, Tara C.
    Hoehler, Matthew S.
    [J]. ACI STRUCTURAL JOURNAL, 2017, 114 (03) : 621 - 630
  • [8] Tensile behavior of post-installed chemical anchors embedded to low strength concrete
    Yilmaz, Salih
    Ozen, Muhammet Ali
    Yardim, Yavuz
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2013, 47 : 861 - 866
  • [9] Experimental study of post-installed corbels with adhesive anchors
    Lannes Damasceno, Joao Henrique
    Catoia, Bruna
    Ferreira, Marcelo de Araujo
    [J]. MAINTENANCE, MONITORING, SAFETY, RISK AND RESILIENCE OF BRIDGES AND BRIDGE NETWORKS, 2016, : 608 - 608
  • [10] Experimental analysis of post-installed corbels with adhesive anchors
    Lannes Damasceno, Joao Henrique
    Catoia, Bruna
    Ferreira, Marcelo de Araujo
    [J]. MATERIA-RIO DE JANEIRO, 2018, 23 (03):