Non-Invasive Monitoring of Cardiac Output in Critical Care Medicine

被引:40
|
作者
Nguyen, Lee S. [1 ]
Squara, Pierre [1 ]
机构
[1] CMC Ambroise Pare, Crit Care Med Dept, Neuilly Sur Seine, France
关键词
non-invasive monitoring; cardiac output; hemodynamics; critical care medicine; bioreactance; THORACIC ELECTRICAL BIOIMPEDANCE; PULMONARY-ARTERY CATHETER; WAVE TRANSIT-TIME; ILL PATIENTS; PULSE-WAVE; TRANSTHORACIC BIOIMPEDANCE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DOPPLER ULTRASOUND; THERMODILUTION; ACCURACY;
D O I
10.3389/fmed.2017.00200
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Critically ill patients require close hemodynamic monitoring to titrate treatment on a regular basis. It allows administering fluid with parsimony and adjusting inotropes and vasoactive drugs when necessary. Although invasive monitoring is considered as the reference method, non-invasive monitoring presents the obvious advantage of being associated with fewer complications, at the expanse of accuracy, precision, and step-response change. A great many methods and devices are now used over the world, and this article focuses on several of them, providing with a brief review of related underlying physical principles and validation articles analysis. Reviewed methods include electrical bioimpedance and bioreactance, respiratory-derived cardiac output (CO) monitoring technique, pulse wave transit time, ultrasound CO monitoring, multimodal algorithmic estimation, and inductance thoracocardiography. Quality criteria with which devices were reviewed included: accuracy (closeness of agreement between a measurement value and a true value of the measured), precision (closeness of agreement between replicate measurements on the same or similar objects under specified conditions), and step response change (delay between physiological change and its indication). Our conclusion is that the offer of non-invasive monitoring has improved in the past few years, even though further developments are needed to provide clinicians with sufficiently accurate devices for routine use, as alternative to invasive monitoring devices.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Evaluation of non-invasive cardiac output monitoring in the presence of hemodynamic instability
    Rita, Kallab
    Roberta, Sudy
    John, Diaper
    Miklos, Kassai
    Andre, Dos Santos Rocha
    Walid, Habre
    Gleicy, Keli Barcelos
    SWISS MEDICAL WEEKLY, 2020, : 5S - 5S
  • [22] Critical review of non-invasive respiratory monitoring in medical care
    Folke, M
    Cernerud, L
    Ekström, M
    Hök, B
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (04) : 377 - 383
  • [23] Critical review of non-invasive respiratory monitoring in medical care
    M. Folke
    L. Cernerud
    M. Ekström
    B. Hök
    Medical and Biological Engineering and Computing, 2003, 41 : 377 - 383
  • [24] Non-invasive cardiac output and oxygen delivery measurement in an infant with critical anemia
    Garry M. Steil
    Olive S. Eckstein
    Julie Caplow
    Michael S. D. Agus
    Brian K. Walsh
    Jackson Wong
    Journal of Clinical Monitoring and Computing, 2011, 25 : 113 - 119
  • [25] NON-INVASIVE CARDIAC OUTPUT AND OXYGEN DELIVERY MEASUREMENT IN AN INFANT WITH CRITICAL ANEMIA
    Steil, Garry M.
    Eckstein, Olive S.
    Caplow, Julie
    Agus, Michael S. D.
    Walsh, Brian K.
    Wong, Jackson
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2011, 25 (02) : 113 - 119
  • [26] NON-INVASIVE MONITORING OF CARDIAC TRANSPLANTS
    BERGMANN, SR
    LERCH, RA
    SAFFITZ, JE
    LEE, S
    SOBEL, BE
    AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (02): : 410 - 410
  • [27] Postoperative continuous non-invasive cardiac output monitoring on the ward: a feasibility study
    King, C. E.
    Kermode, A.
    Saxena, G.
    Carvelli, P.
    Edwards, M.
    Creagh-Brown, B. C.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (06) : 1349 - 1356
  • [28] ASPECTS OF NON-INVASIVE CARDIAC MONITORING
    MANLEY, MT
    THURSFIELD, CD
    MCGUINNESS, JB
    BIOMEDICAL ENGINEERING, 1974, 9 (04): : 144 - 148
  • [29] Non-invasive cardiac output monitoring in pharmacology: a plethysmographic solution in rats.
    Flenet, Timothe
    Fontecave-Jallon, Julie
    Tanguy, Stephane
    Boucher, Francois
    Baconnier, Pierre
    Gumery, Pierre-Yves
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 4933 - 4936
  • [30] Non-invasive continuous cardiac output monitoring in infants with hypoxic ischaemic encephalopathy
    Garvey, Aisling A.
    O'Neill, Roisin
    Livingstone, Vicki
    Pavel, Andreea M.
    Finn, Daragh
    Boylan, Geraldine B.
    Murray, Deirdre M.
    Dempsey, Eugene M.