Non-Invasive Monitoring of Cardiac Output in Critical Care Medicine

被引:40
|
作者
Nguyen, Lee S. [1 ]
Squara, Pierre [1 ]
机构
[1] CMC Ambroise Pare, Crit Care Med Dept, Neuilly Sur Seine, France
关键词
non-invasive monitoring; cardiac output; hemodynamics; critical care medicine; bioreactance; THORACIC ELECTRICAL BIOIMPEDANCE; PULMONARY-ARTERY CATHETER; WAVE TRANSIT-TIME; ILL PATIENTS; PULSE-WAVE; TRANSTHORACIC BIOIMPEDANCE; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DOPPLER ULTRASOUND; THERMODILUTION; ACCURACY;
D O I
10.3389/fmed.2017.00200
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Critically ill patients require close hemodynamic monitoring to titrate treatment on a regular basis. It allows administering fluid with parsimony and adjusting inotropes and vasoactive drugs when necessary. Although invasive monitoring is considered as the reference method, non-invasive monitoring presents the obvious advantage of being associated with fewer complications, at the expanse of accuracy, precision, and step-response change. A great many methods and devices are now used over the world, and this article focuses on several of them, providing with a brief review of related underlying physical principles and validation articles analysis. Reviewed methods include electrical bioimpedance and bioreactance, respiratory-derived cardiac output (CO) monitoring technique, pulse wave transit time, ultrasound CO monitoring, multimodal algorithmic estimation, and inductance thoracocardiography. Quality criteria with which devices were reviewed included: accuracy (closeness of agreement between a measurement value and a true value of the measured), precision (closeness of agreement between replicate measurements on the same or similar objects under specified conditions), and step response change (delay between physiological change and its indication). Our conclusion is that the offer of non-invasive monitoring has improved in the past few years, even though further developments are needed to provide clinicians with sufficiently accurate devices for routine use, as alternative to invasive monitoring devices.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Non-invasive Cardiac Output Monitoring in Congenital Heart Disease
    Tandon A.
    Bhattacharya S.
    Morca A.
    Inan O.T.
    Munther D.S.
    Ryan S.D.
    Latifi S.Q.
    Lu N.
    Lasa J.J.
    Marino B.S.
    Baloglu O.
    Current Treatment Options in Pediatrics, 2023, 9 (4) : 247 - 259
  • [12] Non-invasive cardiac output monitoring during sinus surgery
    Gollapudy, Suneeta
    Riess, Matthias L.
    JOURNAL OF ANESTHESIA, 2015, 29 (04) : 639 - 639
  • [13] Non-invasive cardiac output monitoring during sinus surgery
    Suneeta Gollapudy
    Matthias L. Riess
    Journal of Anesthesia, 2015, 29 : 639 - 639
  • [14] RELIABILITY OF NON-INVASIVE CARDIAC SYSTEM (NICAS® BIOIMPEDANCE AS CARDIAC OUTPUT MONITORING IN CARDIOTHORACIC INTENSIVE CARE
    Tavazzi, G.
    Mebrate, Y.
    White, M.
    Price, S.
    INTENSIVE CARE MEDICINE, 2013, 39 : S235 - S235
  • [15] Cardiac output assessed by non-invasive monitoring is associated with ECG changes in children with critical asthma
    Jackson Wong
    Kate Dorney
    Megan Hannon
    Garry M. Steil
    Journal of Clinical Monitoring and Computing, 2014, 28 : 75 - 82
  • [16] Cardiac output assessed by non-invasive monitoring is associated with ECG changes in children with critical asthma
    Wong, Jackson
    Dorney, Kate
    Hannon, Megan
    Steil, Garry M.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2014, 28 (01) : 75 - 82
  • [17] Non-Invasive Cardiac Output Monitoring in Cardiogenic Shock: The NICOM Study
    Rali, Aniket S.
    Buechler, Tyler
    Van Gotten, Bridget
    Waters, Andrew
    Shah, Zubair
    Haglund, Nicholas
    Sauer, Andrew
    JOURNAL OF CARDIAC FAILURE, 2020, 26 (02) : 160 - 165
  • [18] Continuous non-invasive perioperative monitoring of cardiac output by pulmonary capnotracking
    Peyton, Philip
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 115 - 116
  • [19] In reply: Non-invasive cardiac output monitoring during sinus surgery
    So Hui Yun
    Hyun Jung Kim
    Journal of Anesthesia, 2015, 29 : 640 - 640
  • [20] In reply: Non-invasive cardiac output monitoring during sinus surgery
    Yun, So Hui
    Kim, Hyun Jung
    JOURNAL OF ANESTHESIA, 2015, 29 (04) : 640 - 640