Laboratory-Scale Simulation and Real-Time Tracking of a Microbial Contamination Event and Subsequent Shock-Chlorination in Drinking Water

被引:32
|
作者
Besmer, Michael D. [1 ,2 ]
Sigrist, Jurg A. [1 ]
Props, Ruben [3 ]
Buysschaert, Benjamin [3 ]
Mao, Guannan [1 ,4 ]
Boon, Nico [3 ]
Hammes, Frederik [1 ]
机构
[1] Eawag, Swiss Fed Inst Aquat Sci & Technol, Dept Environm Microbiol, Drinking Water Microbiol Grp, Dubendorf, Switzerland
[2] Inst Biogeochem & Pollutant Dynam, Dept Environm Syst Sci, Zurich, Switzerland
[3] Univ Ghent, Ctr Microbial Ecol & Technol, Ghent, Belgium
[4] Nankai Univ, Tianjin Key Lab Environm Remediat & Pollut Contro, Coll Environm Sci & Engn, Key Lab Pollut Proc & Environm Criteria,Minist Ed, Tianjin, Peoples R China
来源
关键词
continuous real-time flow cytometry; drinking water; bacterial dynamics; disinfection; kinetics; ONLINE FLOW-CYTOMETRY; DISTRIBUTION-SYSTEM; ESCHERICHIA-COLI; VIRAL GASTROENTERITIS; DISEASE OUTBREAKS; WASTE-WATER; QUALITY; VIABILITY; WALKERTON; DYNAMICS;
D O I
10.3389/fmicb.2017.01900
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Rapid contamination of drinking water in distribution and storage systems can occur due to pressure drop, backflow, cross-connections, accidents, and bio-terrorism. Small volumes of a concentrated contaminant (e.g., wastewater) can contaminate large volumes of water in a very short time with potentially severe negative health impacts. The technical limitations of conventional, cultivation-based microbial detection methods neither allow for timely detection of such contaminations, nor for the real-time monitoring of subsequent emergency remediation measures (e.g., shock-chlorination). Here we applied a newly developed continuous, ultra high-frequency flow cytometry approach to track a rapid pollution event and subsequent disinfection of drinking water in an 80-min laboratory scale simulation. We quantified total (TCC) and intact (ICC) cell concentrations as well as flow cytometric fingerprints in parallel in real-time with two different staining methods. The ingress of wastewater was detectable almost immediately (i.e., after 0.6% volume change), significantly changing TCC, ICC, and the flow cytometric fingerprint. Shock chlorination was rapid and detected in real time, causing membrane damage in the vast majority of bacteria (i.e., drop of ICC from more than 380 cells mu l(-1) to less than 30 cells mu l(-1) within 4 min). Both of these effects as well as the final wash-in of fresh tap water followed calculated predictions well. Detailed and highly quantitative tracking of microbial dynamics at very short time scales and for different characteristics (e.g., concentration, membrane integrity) is feasible. This opens up multiple possibilities for targeted investigation of a myriad of bacterial short-term dynamics (e.g., disinfection, growth, detachment, operational changes) both in laboratory-scale research and full-scale system investigations in practice.
引用
收藏
页数:11
相关论文
共 32 条
  • [31] Integrated simulation and optimization scheme of real-time large-scale water supply network: applied to Catalunya case study
    Sun, Cong Cong
    Puig, Vicenc
    Cembrano, Gabriela
    SIMULATION-TRANSACTIONS OF THE SOCIETY FOR MODELING AND SIMULATION INTERNATIONAL, 2015, 91 (01): : 59 - 70
  • [32] Tracking the contribution of multiple raw and treated wastewater discharges at an urban drinking water supply using near real-time monitoring of β-D-glucuronidase activity
    Burnet, Jean-Baptiste
    Sylvestre, Emile
    Jalbert, Jonathan
    Imbeault, Sandra
    Servais, Pierre
    Prevost, Michele
    Dorner, Sarah
    WATER RESEARCH, 2019, 164