Laboratory-Scale Simulation and Real-Time Tracking of a Microbial Contamination Event and Subsequent Shock-Chlorination in Drinking Water

被引:32
|
作者
Besmer, Michael D. [1 ,2 ]
Sigrist, Jurg A. [1 ]
Props, Ruben [3 ]
Buysschaert, Benjamin [3 ]
Mao, Guannan [1 ,4 ]
Boon, Nico [3 ]
Hammes, Frederik [1 ]
机构
[1] Eawag, Swiss Fed Inst Aquat Sci & Technol, Dept Environm Microbiol, Drinking Water Microbiol Grp, Dubendorf, Switzerland
[2] Inst Biogeochem & Pollutant Dynam, Dept Environm Syst Sci, Zurich, Switzerland
[3] Univ Ghent, Ctr Microbial Ecol & Technol, Ghent, Belgium
[4] Nankai Univ, Tianjin Key Lab Environm Remediat & Pollut Contro, Coll Environm Sci & Engn, Key Lab Pollut Proc & Environm Criteria,Minist Ed, Tianjin, Peoples R China
来源
关键词
continuous real-time flow cytometry; drinking water; bacterial dynamics; disinfection; kinetics; ONLINE FLOW-CYTOMETRY; DISTRIBUTION-SYSTEM; ESCHERICHIA-COLI; VIRAL GASTROENTERITIS; DISEASE OUTBREAKS; WASTE-WATER; QUALITY; VIABILITY; WALKERTON; DYNAMICS;
D O I
10.3389/fmicb.2017.01900
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Rapid contamination of drinking water in distribution and storage systems can occur due to pressure drop, backflow, cross-connections, accidents, and bio-terrorism. Small volumes of a concentrated contaminant (e.g., wastewater) can contaminate large volumes of water in a very short time with potentially severe negative health impacts. The technical limitations of conventional, cultivation-based microbial detection methods neither allow for timely detection of such contaminations, nor for the real-time monitoring of subsequent emergency remediation measures (e.g., shock-chlorination). Here we applied a newly developed continuous, ultra high-frequency flow cytometry approach to track a rapid pollution event and subsequent disinfection of drinking water in an 80-min laboratory scale simulation. We quantified total (TCC) and intact (ICC) cell concentrations as well as flow cytometric fingerprints in parallel in real-time with two different staining methods. The ingress of wastewater was detectable almost immediately (i.e., after 0.6% volume change), significantly changing TCC, ICC, and the flow cytometric fingerprint. Shock chlorination was rapid and detected in real time, causing membrane damage in the vast majority of bacteria (i.e., drop of ICC from more than 380 cells mu l(-1) to less than 30 cells mu l(-1) within 4 min). Both of these effects as well as the final wash-in of fresh tap water followed calculated predictions well. Detailed and highly quantitative tracking of microbial dynamics at very short time scales and for different characteristics (e.g., concentration, membrane integrity) is feasible. This opens up multiple possibilities for targeted investigation of a myriad of bacterial short-term dynamics (e.g., disinfection, growth, detachment, operational changes) both in laboratory-scale research and full-scale system investigations in practice.
引用
收藏
页数:11
相关论文
共 32 条
  • [21] Real-time karst groundwater monitoring and bacterial analysis as early warning strategies for drinking water supply contamination
    Fernandez-Ortega, Jaime
    Barbera, Juan Antonio
    Andreo, Bartolome
    SCIENCE OF THE TOTAL ENVIRONMENT, 2024, 912
  • [22] A Low-Cost Sensor Network for Real-Time Monitoring and Contamination Detection in Drinking Water Distribution Systems
    Lambrou, Theofanis P.
    Anastasiou, Christos C.
    Panayiotou, Christos G.
    Polycarpou, Marios M.
    IEEE SENSORS JOURNAL, 2014, 14 (08) : 2765 - 2772
  • [23] Comparison of physical sampling and real-time monitoring strategies for designing a contamination warning system in a drinking water distribution system
    Janke, Robert
    Murray, Regan
    Uber, James
    Taxon, Tom
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2006, 132 (04) : 310 - 313
  • [24] INITIAL FINDINGS ON THE FEASIBILITY OF REAL-TIME FEEDBACK CONTROL OF A HAZARDOUS CONTAMINANT RELEASED INTO CHANNEL FLOW BY MEANS OF A LABORATORY-SCALE PHYSICAL PROTOTYPE
    Rimer, Sara P.
    Katopodes, Nikolaos D.
    Warnock, April M.
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING - 2014, VOL 1B: SYMPOSIA, 2014,
  • [25] Extended virtual pipes for the stable and real-time simulation of small-scale shallow water
    Dagenais, Francois
    Vervondel, Valentin
    Guzman, Julian E.
    Hay, Alexander
    Delorme, Sebastien
    Mould, David
    Paquette, Eric
    COMPUTERS & GRAPHICS-UK, 2018, 76 : 84 - 95
  • [26] Laboratory Development of an AI System for the Real-Time Monitoring of Water Quality and Detection of Anomalies Arising from Chemical Contamination
    Czyczula Rudjord, Zofia
    Reid, Malcolm J.
    Schwermer, Carsten Ulrich
    Lin, Yan
    WATER, 2022, 14 (16)
  • [27] Real-time optical detection of mercury contamination in drinking water using an amphiphilic recognition probe at liquid crystal/aqueous interfaces
    Pandey, Satyabratt
    Rashid, Madeeha
    Singh, Vishal
    Singh, Garima
    Patel, Chandan Bhai
    Verma, Rohit
    Dev, Dharm
    Singh, Ranjan Kumar
    Singh, Sachin Kumar
    ANALYTICAL METHODS, 2024, 16 (47) : 8139 - 8147
  • [28] Portable microfluidic device with thermometer-like display for real-time visual quantitation of Cadmium(II) contamination in drinking water
    Wang, Gaobo
    Wu, Minghui
    Chu, Lok Ting
    Chen, Ting-Hsuan
    ANALYTICA CHIMICA ACTA, 2021, 1160
  • [29] Smart Water Quality Monitoring in Vlora Design of an expert system for real-time monitoring of drinking water and detection of contamination in the aqueduct of the city of Vlora, Albania
    Nasto, Ina
    Zanaj, Eljona
    Bakaj, Aurora
    Bedinaj, Labrina
    Sota, Denada
    Qarri, Flora
    Cipi, Eva
    Salihila, Jonida
    2022 11TH MEDITERRANEAN CONFERENCE ON EMBEDDED COMPUTING (MECO), 2022, : 490 - 497
  • [30] Acoustic feature-based leakage event detection in near real-time for large-scale water distribution networks
    Chew, Alvin Wei Ze
    Kalfarisi, Rony
    Meng, Xue
    Pok, Jocelyn
    Wu, Zheng Yi
    Cai, Jianping
    JOURNAL OF HYDROINFORMATICS, 2023, 25 (02) : 526 - 551