Laboratory-Scale Simulation and Real-Time Tracking of a Microbial Contamination Event and Subsequent Shock-Chlorination in Drinking Water

被引:32
|
作者
Besmer, Michael D. [1 ,2 ]
Sigrist, Jurg A. [1 ]
Props, Ruben [3 ]
Buysschaert, Benjamin [3 ]
Mao, Guannan [1 ,4 ]
Boon, Nico [3 ]
Hammes, Frederik [1 ]
机构
[1] Eawag, Swiss Fed Inst Aquat Sci & Technol, Dept Environm Microbiol, Drinking Water Microbiol Grp, Dubendorf, Switzerland
[2] Inst Biogeochem & Pollutant Dynam, Dept Environm Syst Sci, Zurich, Switzerland
[3] Univ Ghent, Ctr Microbial Ecol & Technol, Ghent, Belgium
[4] Nankai Univ, Tianjin Key Lab Environm Remediat & Pollut Contro, Coll Environm Sci & Engn, Key Lab Pollut Proc & Environm Criteria,Minist Ed, Tianjin, Peoples R China
来源
关键词
continuous real-time flow cytometry; drinking water; bacterial dynamics; disinfection; kinetics; ONLINE FLOW-CYTOMETRY; DISTRIBUTION-SYSTEM; ESCHERICHIA-COLI; VIRAL GASTROENTERITIS; DISEASE OUTBREAKS; WASTE-WATER; QUALITY; VIABILITY; WALKERTON; DYNAMICS;
D O I
10.3389/fmicb.2017.01900
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Rapid contamination of drinking water in distribution and storage systems can occur due to pressure drop, backflow, cross-connections, accidents, and bio-terrorism. Small volumes of a concentrated contaminant (e.g., wastewater) can contaminate large volumes of water in a very short time with potentially severe negative health impacts. The technical limitations of conventional, cultivation-based microbial detection methods neither allow for timely detection of such contaminations, nor for the real-time monitoring of subsequent emergency remediation measures (e.g., shock-chlorination). Here we applied a newly developed continuous, ultra high-frequency flow cytometry approach to track a rapid pollution event and subsequent disinfection of drinking water in an 80-min laboratory scale simulation. We quantified total (TCC) and intact (ICC) cell concentrations as well as flow cytometric fingerprints in parallel in real-time with two different staining methods. The ingress of wastewater was detectable almost immediately (i.e., after 0.6% volume change), significantly changing TCC, ICC, and the flow cytometric fingerprint. Shock chlorination was rapid and detected in real time, causing membrane damage in the vast majority of bacteria (i.e., drop of ICC from more than 380 cells mu l(-1) to less than 30 cells mu l(-1) within 4 min). Both of these effects as well as the final wash-in of fresh tap water followed calculated predictions well. Detailed and highly quantitative tracking of microbial dynamics at very short time scales and for different characteristics (e.g., concentration, membrane integrity) is feasible. This opens up multiple possibilities for targeted investigation of a myriad of bacterial short-term dynamics (e.g., disinfection, growth, detachment, operational changes) both in laboratory-scale research and full-scale system investigations in practice.
引用
收藏
页数:11
相关论文
共 32 条
  • [1] Real-time optimization for a laboratory-scale flotation column
    Navia, Daniel
    Villegas, Diego
    Cornejo, Ivan
    de Prada, Cesar
    COMPUTERS & CHEMICAL ENGINEERING, 2016, 86 : 62 - 74
  • [2] Contamination Event Detection in Drinking Water Systems Using a Real-Time Learning Approach
    Eliades, Demetrios G.
    Panayiotou, Christos
    Polycarpou, Marios M.
    PROCEEDINGS OF THE 2014 INTERNATIONAL JOINT CONFERENCE ON NEURAL NETWORKS (IJCNN), 2014, : 663 - 670
  • [3] Detection of drinking water contamination by an optical real-time bacteria sensor
    Hojris, B.
    Kornholt, S. N.
    Christensen, S. C. B.
    Albrechtsen, H-J
    Olesen, L. S.
    H2OPEN JOURNAL, 2018, 1 (02) : 160 - 168
  • [4] The Development of Laboratory-Scale Oscillating Water Column OWC Test Rig with Real-Time Data Monitoring System
    Hiron, Nurul
    Giriantari, Ida Ayu Dwi
    Jasa, Lie
    Kumara, I. Nyoman Satya
    2021 INTERNATIONAL CONFERENCE ON SMART-GREEN TECHNOLOGY IN ELECTRICAL AND INFORMATION SYSTEMS (ICSGTEIS), 2021, : 12 - 17
  • [5] Clustering for Real-Time Response to Water Distribution System Contamination Event Intrusions
    Lifshitz, Ron
    Ostfeld, Avi
    JOURNAL OF WATER RESOURCES PLANNING AND MANAGEMENT, 2019, 145 (02)
  • [6] Online fluorescence spectroscopy for the real-time evaluation of the microbial quality of drinking water
    Sorensen, J. P. R.
    Vivanco, A.
    Ascott, M. J.
    Gooddy, D. C.
    Lapworth, D. J.
    Read, D. S.
    Rushworth, C. M.
    Bucknall, J.
    Herbert, K.
    Karapanos, I
    Gumm, L. P.
    Taylor, R. G.
    WATER RESEARCH, 2018, 137 : 301 - 309
  • [7] An Accurate Machine for Real-Time Two-Phase Flowmetering in a Laboratory-Scale Flow Loop
    Meribout, Mahmoud
    Al-Rawahi, Nabeel Z.
    Al-Naamany, Ahmed M.
    Al-Bimani, Ali
    Al Busaidi, Khamis
    Meribout, Adel
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (08) : 2686 - 2696
  • [8] Real-time surrogate analysis for potential oil and gas contamination of drinking water resources
    Son J.-H.
    Carlson K.H.
    Appl. Water Sci., 3 (283-289): : 283 - 289
  • [9] Virtual sensing for real-time strain field estimation and its verification on a laboratory-scale jacket structure under water waves
    Lee, Sungbo
    Park, Moonsu
    Oh, Min-Han
    Lee, Phill-Seung
    COMPUTERS & STRUCTURES, 2024, 298
  • [10] Real-Time Simulation and Control of Large Scale Distributed Discrete Event Systems
    Gonzalez, Fernando G.
    2013 CONFERENCE ON SYSTEMS ENGINEERING RESEARCH, 2013, 16 : 177 - 186