Use of straight and curved 3-dimensional titanium miniplates for fracture fixation at the mandibular angle

被引:52
|
作者
Zix, Juergen [1 ]
Lieger, Olivier [1 ]
Iizuka, Tateyuki [1 ]
机构
[1] Univ Bern, Dept Cranio Maxillofacial Surg, CH-3010 Bern, Switzerland
关键词
D O I
10.1016/j.joms.2007.03.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this follow-up study was to evaluate the clinical usefulness of a new type of 3-dimensional (3D) miniplate for open reduction and monocortical fixation of mandibular angle fractures. Patients and Methods: In 20 consecutive patients, noncomminuted mandibular angle fractures were treated with open reduction and fixation using a 2 mm 3D miniplate system in a transoral approach. All patients were systematically monitored until 6 months postoperatively. Among the outcome parameters recorded were infection, hardware failure, wound dehiscence, and sensory disturbance of the inferior alveolar nerve. Results: The mean operation time from incision to wound closure was 65 minutes. Two patients had a mucosal wound dehiscence with no consequences. None developed an infection requiring a plate removal. All but 2 patients had normal sensory function 3 months after surgery. Plate fracture occurred in one patient in whom a preceding surgical removal of the third molar had been the reason for the mandibular fracture. In the absence of clinical symptoms, the patient declined plate removal. On final follow-up, fracture healing was considered clinically complete in all patients. Conclusions: The 3D plating system described here is suitable for fixation of simple mandibular angle fractures and is an easy-to-use alternative to conventional miniplates. The system may be contraindicated in patients in whom insufficient interfragmentary bone contact causes minor stability of the fracture. (C) 2007 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:1758 / 1763
页数:6
相关论文
共 50 条
  • [31] Comparison of biting force when using a combination of one microplate and one miniplate versus two miniplates for fixation of parasymphyseal mandibular fracture: the use of microplates for parasymphyseal mandibular fracture
    Magdy Mohamed Zaky
    Nabila Ali Fayed
    Mohamed Farid Shehab
    Oral and Maxillofacial Surgery, 2020, 24 : 19 - 24
  • [32] Comparison of biting force when using a combination of one microplate and one miniplate versus two miniplates for fixation of parasymphyseal mandibular fracture: the use of microplates for parasymphyseal mandibular fracture
    Zaky, Magdy Mohamed
    Fayed, Nabila Ali
    Shehab, Mohamed Farid
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2020, 24 (01): : 19 - 24
  • [33] Clinical feasibility and efficiency of a 3-dimensional printed surgical template for mandibular angle osteotomy and mandibular angle splitting osteotomy
    He, D.
    Du, W.
    Li, J.
    Liu, L.
    Luo, E.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2018, 56 (07): : 594 - 599
  • [34] Comparative Evaluation of 3d Locking Versus Non-Locking Titanium Miniplates in the Treatment of Mandibular Fracture
    Mohsin Khan
    Ashish Vishal
    Tanya Kumar
    Dharmendra Kumar Khaitan
    Chandan Sinha
    Indian Journal of Otolaryngology and Head & Neck Surgery, 2020, 72 : 363 - 369
  • [35] Comparative Evaluation of 3d Locking Versus Non-Locking Titanium Miniplates in the Treatment of Mandibular Fracture
    Khan, Mohsin
    Vishal
    Kumar, Ashish
    Khaitan, Tanya
    Sinha, Dharmendra Kumar
    Kumar, Chandan
    INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2020, 72 (03) : 363 - 369
  • [36] Biomechanical Comparison of Four Mandibular Angle Fracture Fixation Techniques
    Munante-Cardenas, Jose Luis
    Passeri, Luis Augusto
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2015, 8 (02) : 123 - 128
  • [37] Which fixation methods are better between three-dimensional anatomical plate and two miniplates for the mandibular subcondylar fracture open treatment?
    Sukegawa, Shintaro
    Kanno, Takahiro
    Masui, Masanori
    Sukegawa-Takahashi, Yuka
    Kishimoto, Tsukasa
    Sato, Ai
    Furuki, Yoshihiko
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (05) : 771 - 777
  • [38] A retrospective comparative study of mandibular fracture treatment with internal fixation using reconstruction plate versus miniplates
    Sukegawa, Shintaro
    Kanno, Takahiro
    Masui, Masanori
    Sukegawa-Takahashi, Yuka
    Kishimoto, Tsukasa
    Sato, Ai
    Furuki, Yoshihiko
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (08) : 1175 - 1180
  • [39] Versatility of Titanium 3D Plate in Comparison with Conventional Titanium Miniplate Fixation for the Management of Mandibular Fracture
    Malhotra, Kamal
    Sharma, Ashish
    Giraddi, Girish
    Shahi, Ashish Kumar
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2012, 11 (03): : 284 - 290
  • [40] Versatility of Titanium 3D Plate in Comparison with Conventional Titanium Miniplate Fixation for the Management of Mandibular Fracture
    Kamal Malhotra
    Ashish Sharma
    Girish Giraddi
    Ashish Kumar Shahi
    Journal of Maxillofacial and Oral Surgery, 2012, 11 (3) : 284 - 290