Use of straight and curved 3-dimensional titanium miniplates for fracture fixation at the mandibular angle

被引:52
|
作者
Zix, Juergen [1 ]
Lieger, Olivier [1 ]
Iizuka, Tateyuki [1 ]
机构
[1] Univ Bern, Dept Cranio Maxillofacial Surg, CH-3010 Bern, Switzerland
关键词
D O I
10.1016/j.joms.2007.03.013
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this follow-up study was to evaluate the clinical usefulness of a new type of 3-dimensional (3D) miniplate for open reduction and monocortical fixation of mandibular angle fractures. Patients and Methods: In 20 consecutive patients, noncomminuted mandibular angle fractures were treated with open reduction and fixation using a 2 mm 3D miniplate system in a transoral approach. All patients were systematically monitored until 6 months postoperatively. Among the outcome parameters recorded were infection, hardware failure, wound dehiscence, and sensory disturbance of the inferior alveolar nerve. Results: The mean operation time from incision to wound closure was 65 minutes. Two patients had a mucosal wound dehiscence with no consequences. None developed an infection requiring a plate removal. All but 2 patients had normal sensory function 3 months after surgery. Plate fracture occurred in one patient in whom a preceding surgical removal of the third molar had been the reason for the mandibular fracture. In the absence of clinical symptoms, the patient declined plate removal. On final follow-up, fracture healing was considered clinically complete in all patients. Conclusions: The 3D plating system described here is suitable for fixation of simple mandibular angle fractures and is an easy-to-use alternative to conventional miniplates. The system may be contraindicated in patients in whom insufficient interfragmentary bone contact causes minor stability of the fracture. (C) 2007 American Association of Oral and Maxillofacial Surgeons.
引用
收藏
页码:1758 / 1763
页数:6
相关论文
共 50 条
  • [22] Comparison of 3-Dimensional and Standard Miniplate Fixation in the Management of Mandibular Fractures
    Jain, Manoj Kumar
    Manjunath, K. S.
    Bhagwan, B. K.
    Shah, Dipit K.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (07) : 1568 - 1572
  • [23] Resorbable Plates for the Fixation of Isolated Mandibular Angle Fracture
    Yang, Rong-tao
    Lv, Kun
    Zhou, Hai-hua
    Li, Zhi
    Li, Zu-bing
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (02) : 447 - 448
  • [24] Evaluation of 2.0-mm Titanium Three-Dimensional Curved Angle Strut Plate in the Fixation of Mandibular Angle Fractures-A Prospective Clinical and Radiological Analysis
    Chhabaria, Gaurav
    Halli, Rajshekhar
    Chandan, Sanjay
    Joshi, Samir
    Setiya, Sneha
    Shah, Anand
    CRANIOMAXILLOFACIAL TRAUMA & RECONSTRUCTION, 2014, 7 (02) : 119 - 125
  • [25] Assessment of CAD/CAM Customized V Pattern Plate Versus Standard Miniplates Fixation in Mandibular Angle Fracture (Randomized Clinical Trial)
    Hiba Obad Saleh
    Basma Gamal Moussa
    Khaled Amr Salah Eddin
    Samer Abduljabar Noman
    Ahmed Mohammed Salah
    Journal of Maxillofacial and Oral Surgery, 2023, 22 : 995 - 1005
  • [26] Intraoperative 3-dimensional imaging of scaphoid fracture reduction and fixation
    Luria, S.
    Safran, O.
    Zinger, G.
    Mosheiff, R.
    Liebergall, M.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2015, 101 (03) : 353 - 357
  • [27] Evaluation of two internal fixation techniques for mandibular parasymphyseal fractures comparing conventional titanium miniplates with customised titanium CRB omega miniplates: a prospective study
    Bande, C. R.
    Kurawar, K. R.
    Mishra, A.
    Joshi, A.
    Goel, M.
    Mahajan, M. R.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2018, 56 (06): : 520 - 524
  • [28] Assessment of CAD/CAM Customized V Pattern Plate Versus Standard Miniplates Fixation in Mandibular Angle Fracture (Randomized Clinical Trial)
    Saleh, Hiba Obad
    Moussa, Basma Gamal
    Salah Eddin, Khaled Amr
    Noman, Samer Abduljabar
    Salah, Ahmed Mohammed
    JOURNAL OF MAXILLOFACIAL & ORAL SURGERY, 2023, 22 (04): : 995 - 1005
  • [29] COMPARATIVE EVALUATION OF THE MECHANICAL PROPERTIES OF RESORBABLE AND TITANIUM MINIPLATES USED FOR FIXATION OF MANDIBULAR CONDYLE FRACTURES
    Cansiz, Erol
    Dogru, Suzan Cansel
    Arslan, Yunus Ziya
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2015, 15 (02)
  • [30] USE OF 3-DIMENSIONAL PHOTOELASTICITY IN FRACTURE MECHANICS
    SMITH, CW
    EXPERIMENTAL MECHANICS, 1973, 13 (12) : 539 - 544