Label-free detection of nosocomial bacteria using a nanophotonic interferometric biosensor

被引:1
|
作者
Maldonado, Jesus [1 ,2 ]
Estevez, M. -Carmen [1 ,2 ]
Fernandez-Gavela, Adrian [1 ,2 ]
Jose Gonzalez-Lopez, Juan [3 ]
Belen Gonzalez-Guerrero, Ana [1 ,2 ]
Lechuga, Laura M. [1 ,2 ]
机构
[1] Catalan Inst Nanosci & Nanotechnol ICN2, CSIC, Nanobiosensors & Bioanalyt Applicat Grp, CIBER,BBN, Campus UAB, Barcelona 08193, Spain
[2] BIST, Campus UAB, Barcelona 08193, Spain
[3] Univ Autonoma Barcelona, Vall dHebron Inst Recerca VHIR, Hosp Univ Vall dHebron, Dept Clin Microbiol, Barcelona 08035, Spain
关键词
RESISTANT STAPHYLOCOCCUS-AUREUS; PSEUDOMONAS-AERUGINOSA; MRSA; DIAGNOSIS; SILICON; GENE; MECA;
D O I
10.1039/c9an01485c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Nosocomial infections are a major concern at the worldwide level. Early and accurate identification of nosocomial pathogens is crucial to provide timely and adequate treatment. A prompt response also prevents the progression of the infection to life-threatening conditions, such as septicemia or generalized bloodstream infection. We have implemented two highly sensitive methodologies using an ultrasensitive photonic biosensor based on a bimodal waveguide interferometer (BiMW) for the fast detection of Pseudomonas aeruginosa and methicillin-resistant Staphylococcus aureus (MRSA), two of the most prevalent bacteria associated with nosocomial infections. For that, we have developed a biofunctionalization strategy based on the use of a PEGylated silane (silane-PEG-COOH) which provides a highly resistant and bacteria-repelling surface, which is crucial to specifically detect each bacterium. Two different biosensor assays have been set under standard buffer conditions: one based on a specific direct immunoassay employing polyclonal antibodies for the detection of P. aeruginosa and another one employing aptamers for the direct detection of MRSA. The biosensor immunoassay for P. aeruginosa is fast (it only takes 12 min) and specific and has experimentally detected concentrations down to 800 cfu mL(-1) (cfu: colony forming unit). The second one relies on the use of an aptamer that specifically detects penicillin-binding protein 2a (PBP2a), a protein only expressed in the MRSA mutant, providing a photonic biosensor with the ability to identify the resistant pathogen MRSA and differentiate it from methicillin-susceptible S. aureus (MSSA). Direct, label-free, and selective detection of whole MRSA bacteria has been achieved, making possible the direct detection of also 800 cfu mL(-1). According to the signal-to-noise (S/N) ratio of the device, a theoretical limit of detection (LOD) of around 49 and 29 cfu mL(-1) was estimated for P. aeruginosa and MRSA, respectively. Both results obtained under standard conditions reveal the great potential this interferometric biosensor device has as a versatile and specific tool for bacterial detection and quantification, providing a rapid method for the identification of nosocomial pathogens within the clinical requirements of sensitivity for the diagnosis of infections.
引用
收藏
页码:497 / 506
页数:10
相关论文
共 50 条
  • [21] Microwave biosensors for label-free bacteria detection
    Piekarz, Ilona
    Sorocki, Jakub
    Gorska, Sabina
    Wincza, Krzysztof
    Gruszczynski, Slawomir
    2023 IEEE MTT-S INTERNATIONAL MICROWAVE BIOMEDICAL CONFERENCE, IMBIOC, 2023, : 109 - 111
  • [22] Optical Methods for Label-Free Detection of Bacteria
    Wang, Pengcheng
    Sun, Hao
    Yang, Wei
    Fang, Yimin
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [23] Label-free detection of nanoparticles using depth scanning correlation interferometric microscopy
    Ugur Aygun
    Hakan Urey
    Ayca Yalcin Ozkumur
    Scientific Reports, 9
  • [24] Label-free detection of lysozyme in wines using an aptamer based biosensor and SPR detection
    Mihai, Luliana
    Vezeanu, Alis
    Polonschii, Cristina
    Albu, Camelia
    Radu, Gabriel-Lucian
    Vasilescu, Alina
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 206 : 198 - 204
  • [25] Label-free detection of cardiac biomarker using aptamer based capacitive biosensor
    Qureshi, Anjum
    Gurbuz, Yasar
    Niazi, Javed H.
    EUROSENSORS XXIV CONFERENCE, 2010, 5 : 828 - 830
  • [26] Detection of Oxytetracycline Using an Electrochemical Label-Free Aptamer-Based Biosensor
    Akbarzadeh, Sanaz
    Khajehsharifi, Habibollah
    Hajihosseini, Saeedeh
    BIOSENSORS-BASEL, 2022, 12 (07):
  • [27] Blood Biomarker Detection Using Integrated Microfluidics with Optical Label-Free Biosensor
    Li, Chiung-Hsi
    Chang, Chen-Yuan
    Chen, Yan-Ru
    Huang, Cheng-Sheng
    SENSORS, 2024, 24 (20)
  • [28] Nanophotonic label-free biosensors for environmental monitoring
    Chocarro-Ruiz, Blanca
    Fernandez-Gavela, Adrian
    Herranz, Sonia
    Lechuga, Laura M.
    CURRENT OPINION IN BIOTECHNOLOGY, 2017, 45 : 175 - 183
  • [29] Interferometric biosensor based on planar optical waveguide sensor chips for label-free detection of surface bound bioreactions
    Schmitt, Katrin
    Schirmer, Bernd
    Hoffmann, Christian
    Brandenburg, Albrecht
    Meyrueis, Patrick
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11): : 2591 - 2597
  • [30] Label-free detection of bovine serum albumin based on an in-fiber Mach-Zehnder interferometric biosensor
    Li, Zhengyong
    Liao, Changrui
    Chen, Danni
    Song, Jun
    Jin, Wei
    Peng, Gang-Ding
    Zhu, Feng
    Wang, Ying
    He, Jun
    Wang, Yiping
    OPTICS EXPRESS, 2017, 25 (15): : 17105 - 17113