Speech Perception Outcomes in Transcutaneous Versus Percutaneous Bone Conduction Stimulation in Individuals With Single-sided Deafness

被引:7
|
作者
Snapp, Hillary A. [1 ]
Morgenstein, Kari E. [1 ]
Kuzbyt, Brianna [1 ]
机构
[1] Univ Miami, Miller Sch Med, Ear Inst, Dept Otolaryngol, Miami, FL 33136 USA
关键词
BAHA; Bone anchored implant; Bone-conduction; Osseointegrated implant; Percutaneous; Single-sided deafness; Speech-in-noise; Transcutaneous; ANCHORED HEARING-AIDS; TRANSCRANIAL ATTENUATION; UNILATERAL DEAFNESS; HIGH-FREQUENCY; IN-NOISE; IMPLANT; BAHA; REHABILITATION; SOUND; AMPLIFICATION;
D O I
10.1097/MAO.0000000000002362
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective(s): To investigate the differences in percutaneous versus passive transcutaneous bone-conduction stimulation in individuals with single-sided deafness. Study Design: Prospective, single-subject. Setting: Tertiary academic referral center. Patients: Adult bone-anchored implant listeners with single-sided deafness using a percutaneous implant system. Interventions: Experienced percutaneous bone anchored implant recipients were tested in the percutaneous and transcutaneous conditions using a BAHA 5 (Cochlear Corp., Cochlear Bone-Anchored Solutions, Molnlycke, Sweden) sound processor on the patient's own abutment and on a softband. Main Outcome Measures: Phoneme recognition was assessed using Consonant-Nucleus-Consonant (CNC) words for soft (47 dB SPL) and average (62 dB SPL) speech inputs. Speech perception in noise performance was also assessed for soft (47 dB SPL) and average (62 dB SPL) speech inputs using sentences presented in multi-talker babble. Aided free-field thresholds were obtained in both conditions using warble tone stimuli. Results: Compared with percutaneous bone-conduction stimulation, transcutaneous stimulation demonstrated reduced effective gain for high frequency stimulation. Transcutaneous stimulation required higher signal to noise ratios to achieve comparable performance to the percutaneous condition. Phoneme recognition was poorer in transcutaneous versus percutaneous stimulation with the most significant impact observed for soft speech inputs. Conclusion: A significant performance gap in speech recognition is observed between percutaneous and transcutaneous bone-conduction stimulation in individuals with single-sided deafness at the same signal to noise ratios. Compared with percutaneous bone-conduction stimulation, transcutaneous stimulation demonstrated reduced effective gain, decreased phoneme recognition, word recognition, and performance in noise, with the most significant impact observed for soft speech inputs.
引用
收藏
页码:1068 / 1075
页数:8
相关论文
共 50 条
  • [41] Mechanisms of Localization and Speech Perception with Colocated and Spatially Separated Noise and Speech Maskers Under Single-Sided Deafness with a Cochlear Implant
    Dirks, Coral
    Nelson, Peggy B.
    Sladen, Douglas P.
    Oxenham, Andrew J.
    EAR AND HEARING, 2019, 40 (06): : 1293 - 1306
  • [42] Improving Auditory Perception in Pediatric Single-Sided Deafness: Use of Cochlear Implants? Direct Connection for Remote Speech Perception Rehabilitation
    Agostinelli, Anna
    Pegolo, Margherita
    Montino, Silvia
    Maritan, Francesca
    Gambalonga, Mattia
    Trevisi, Patrizia
    Brotto, Davide
    AMERICAN JOURNAL OF AUDIOLOGY, 2023, 32 (01) : 52 - 58
  • [43] Anatomy-based fitting improves speech perception in noise for cochlear implant recipients with single-sided deafness
    Kurz, Anja
    Herrmann, David
    Mueller-Graff, Franz-Tassilo
    Voelker, Johannes
    Hackenberg, Stephan
    Rak, Kristen
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2025, 282 (01) : 467 - 479
  • [44] Efficacy of the Bone-Anchored Hearing Aid for Single-Sided Deafness
    Linstrom, Christopher J.
    Silverman, Carol A.
    Yu, Guo-Pei
    LARYNGOSCOPE, 2009, 119 (04): : 713 - 720
  • [45] Management of single-sided deafness with the bone-anchored hearing aid
    Yuen, Heng-Wai
    Bodmer, Daniel
    Smilsky, Kari
    Nedzelski, Julian M.
    Chen, Joseph M.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2009, 141 (01) : 16 - 23
  • [46] Comparison of 2 Implantable Bone Conduction Devices in Patients With Single-Sided Deafness Using a Daily Alternating Method
    Desmet, Jolien Brigit Johan
    Wouters, Kristien
    De Bodt, Marc
    Van de Heyning, Paul
    OTOLOGY & NEUROTOLOGY, 2012, 33 (06) : 1018 - 1026
  • [47] Cochlear Implantation in Adults With Single-sided Deafness: Outcomes and Device Use
    Deep, Nicholas L.
    Spitzer, Emily R.
    Shapiro, William H.
    Waltzman, Susan B.
    Roland, J. Thomas, Jr.
    Friedmann, David R.
    OTOLOGY & NEUROTOLOGY, 2021, 42 (03) : 414 - 423
  • [48] Ear-specific neuroplasticity for sound localization in individuals with single-sided deafness
    Shim, Leeseul
    Kim, Jahee
    Kim, Gibbeum
    Lee, Hyo-Jeong
    HEARING RESEARCH, 2025, 459
  • [49] Effect of Tinnitus and Duration of Deafness on Sound Localization and Speech Recognition in Noise in Patients With Single-Sided Deafness
    Liu, Yang-Wenyi
    Cheng, Xiaoting
    Chen, Bing
    Peng, Kevin
    Ishiyama, Akira
    Fu, Qian-Jie
    TRENDS IN HEARING, 2018, 22
  • [50] Audiological Results and Quality of Life of Sophono Alpha 2 Transcutaneous Bone-Anchored Implant Users in Single-Sided Deafness
    Bernardeschi, Daniele
    Russo, Francesca Yoshie
    Nguyen, Yann
    Vicault, Eric
    Flament, Jonathan
    Bernou, Deborah
    Sterkers, Olivier
    Mosnier, Isabelle
    AUDIOLOGY AND NEURO-OTOLOGY, 2016, 21 (03) : 158 - 164