Objective(s): To investigate the differences in percutaneous versus passive transcutaneous bone-conduction stimulation in individuals with single-sided deafness. Study Design: Prospective, single-subject. Setting: Tertiary academic referral center. Patients: Adult bone-anchored implant listeners with single-sided deafness using a percutaneous implant system. Interventions: Experienced percutaneous bone anchored implant recipients were tested in the percutaneous and transcutaneous conditions using a BAHA 5 (Cochlear Corp., Cochlear Bone-Anchored Solutions, Molnlycke, Sweden) sound processor on the patient's own abutment and on a softband. Main Outcome Measures: Phoneme recognition was assessed using Consonant-Nucleus-Consonant (CNC) words for soft (47 dB SPL) and average (62 dB SPL) speech inputs. Speech perception in noise performance was also assessed for soft (47 dB SPL) and average (62 dB SPL) speech inputs using sentences presented in multi-talker babble. Aided free-field thresholds were obtained in both conditions using warble tone stimuli. Results: Compared with percutaneous bone-conduction stimulation, transcutaneous stimulation demonstrated reduced effective gain for high frequency stimulation. Transcutaneous stimulation required higher signal to noise ratios to achieve comparable performance to the percutaneous condition. Phoneme recognition was poorer in transcutaneous versus percutaneous stimulation with the most significant impact observed for soft speech inputs. Conclusion: A significant performance gap in speech recognition is observed between percutaneous and transcutaneous bone-conduction stimulation in individuals with single-sided deafness at the same signal to noise ratios. Compared with percutaneous bone-conduction stimulation, transcutaneous stimulation demonstrated reduced effective gain, decreased phoneme recognition, word recognition, and performance in noise, with the most significant impact observed for soft speech inputs.
引用
收藏
页码:1068 / 1075
页数:8
相关论文
共 50 条
  • [21] Sound Source Localization Testing in Single-sided Deafness Following Bone Conduction Intervention
    Zhang, Xiao
    Bai, Jie
    Lin, Zhihan
    Li, Ying
    Liu, Haihong
    Yang, Yang
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (214):
  • [22] Performance with a new bone conduction implant audio processor in patients with single-sided deafness
    Wilhelm Wimmer
    Michael Zbinden
    Tom Gawliczek
    Alexander Huber
    Marco Caversaccio
    Martin Kompis
    European Archives of Oto-Rhino-Laryngology, 2023, 280 : 3585 - 3591
  • [23] Bone anchored hearing aids for single-sided deafness
    Baguley, D. M.
    Plydoropulou, V
    Prevost, A. T.
    CLINICAL OTOLARYNGOLOGY, 2009, 34 (02) : 176 - 177
  • [24] Acoustic Hearing Can Interfere With Single-Sided Deafness Cochlear-Implant Speech Perception
    Bernstein, Joshua G. W.
    Stakhovskaya, Olga A.
    Jensen, Kenneth Kragh
    Goupell, Matthew J.
    EAR AND HEARING, 2020, 41 (04): : 747 - 761
  • [25] Horizontal sound localisation and speech perception in Bonebridge-implanted single-sided deafness patients
    Zhao, C.
    Yang, J.
    Liu, Y.
    Gao, M.
    Chen, P.
    Zheng, J.
    Zhao, S.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2020, 134 (09): : 814 - 821
  • [26] Speech Perception in Noise After Cochlear Implantation for Single-Sided Deafness A Randomized Clinical Trial
    van Heteren, Jan A. A.
    Wendrich, Anne W.
    Peters, Jeroen P. M.
    Grolman, Wilko
    Stokroos, Robert J.
    Smit, Adriana L.
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2025, 151 (03) : 211 - 219
  • [27] Right Ear Advantage of Speech Audiometry in Single-sided Deafness
    Wettstein, Vincent G.
    Probst, Rudolf
    OTOLOGY & NEUROTOLOGY, 2018, 39 (04) : 417 - 421
  • [28] Clinical experience of an adhesive bone conduction hearing system in children with congenital single-sided deafness
    Liu, Yujie
    Qiu, Wenxi
    Yang, Lin
    Wang, Yuan
    Zhu, Jikai
    Lv, Mengshuang
    Zhao, Shouqin
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2024, 90 (04)
  • [29] Place dependent stimulation rates improve pitch perception in cochlear implantees with single-sided deafness
    Rader, Tobias
    Doege, Julia
    Adel, Youssef
    Weissgerber, Tobias
    Baumann, Uwe
    HEARING RESEARCH, 2016, 339 : 94 - 103
  • [30] COST-EFFECTIVENESS ANALYSIS OF AN ACTIVE TRANSCUTANEOUS BONE CONDUCTION IMPLANT FOR PATIENTS WITH CONDUCTIVE OR MIXED HEARING LOSS OR SINGLE-SIDED DEAFNESS IN TURKEY
    Kiesewetter, K.
    Dejaco, T.
    Hoch, A.
    Scandurra, F.
    Rose-Eichberger, K.
    Schwarz Mag, C.
    Urban, M.
    Kockaya, G.
    Okcun, S.
    Kurnaz, M.
    VALUE IN HEALTH, 2022, 25 (12) : S69 - S69