Assessment of PV technologies outdoor performance and commercial software estimation in hot and dry climates

被引:11
|
作者
Othman, Radwa [1 ,2 ]
Hatem, Tarek M. [2 ,3 ]
机构
[1] Schneider Elect, Second Dist,Fifth Settlement, Cairo 11835, Egypt
[2] British Univ Egypt, Ctr Simulat Innovat & Adv Mfg, Cairo 11837, Egypt
[3] British Univ Egypt, Fac Energy & Environm Engn, Cairo 11837, Egypt
关键词
Photovoltaic; Poly-crystalline; Mono-crystalline; Thin-film CdTe; PV degradation; Hot and dry climate; SILICON PHOTOVOLTAIC MODULES; DEGRADATION; SYSTEM; ENERGY; EFFICIENCY; EXPOSURE; PANELS; SOUTH;
D O I
10.1016/j.jclepro.2022.130819
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Photovoltaic (PV) technologies have become an essential part of the global effort to compact climate change. While the MENA region, and in particular Egypt, has been one of the main target locations for PV system installations; because of the region's tremendous potential for solar energy and its location on the sunbelt. Yet, a gap in both literature and long-term industrial experience of PV technologies' installation in this particular region calls for investigation. Therefore, this work focuses on two main objectives: first, conducting an evaluation of long-term outdoor performance of three grid-connected photovoltaic systems (i.e. poly-crystalline, mono crystalline, and thin-film Cadmium Telluride) installed on the same rooftop in Cairo, Egypt, since October 2013. In which, the three systems will be compared in terms of yield, degradation rate, modules efficiency, and temperature power coefficient. The second objective is to compare the performance of commonly-used commercial software packages (i.e. PVSyst, PVSol, and SMA Sunny Design Web) to the output of the three PV systems mentioned above.In terms of degradation, the average yield degradation value was 1.19%/year, 1.17%/year, and 1.67%/year for poly-crystalline, mono-crystallin, and thin-film Cadmium Telluride respectively. For degradation against temperature, the rates were 1.53%/C/kW(p), 1.22%/C/kW(p), and 1.06%/C/kW(p) for the three systems respectively. As for software packages estimation, all three software tend to produce a reasonably accurate annual estimation but they become significantly less accurate with the monthly estimation. The annual errors of the three software ranged from-6.99% to +4.65% which is consistent with the literature. However, the monthly error introduced in this study of the three software ranged from-23.71% to +22.22%.The current work lays down the foundation to enhance PV systems' performance in hot and dry climates, as well as, calls for more accurate models for different PV technologies, especially for hot and dry climates.
引用
收藏
页数:18
相关论文
共 50 条
  • [21] Outdoor Performance Testing of Thin-Film PV Modules in the Hot and Humid Climate
    Dhere, Neelkanth G.
    Kaul, Ashwani
    Pethe, Shirish A.
    Schneller, Eric
    Shiradkar, Narendra S.
    2013 IEEE 39TH PHOTOVOLTAIC SPECIALISTS CONFERENCE (PVSC), 2013, : 2994 - 2997
  • [22] Assessing the impact of PV facades on neighborhood microclimate, outdoor thermal comfort, and energy efficiency in hot climates, case study of Shiraz
    Ahmadizadeh, Omid
    Vakilinezhad, Roza
    ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT, 2025,
  • [23] Energy and economic performance of rooftop PV panels in the hot and dry climate of Iran
    Korsavi, Sepideh Sadat
    Zomorodian, Zahra Sadat
    Tahsildoost, Mohammad
    JOURNAL OF CLEANER PRODUCTION, 2018, 174 : 1204 - 1214
  • [24] Techno-Economic Assessment of Rooftop PV Systems in Residential Buildings in Hot-Humid Climates
    Dehwah, Ammar Hamoud Ahmad
    Asif, Muhammad
    Budaiwi, Ismail Mohammad
    Alshibani, Adel
    SUSTAINABILITY, 2020, 12 (23) : 1 - 19
  • [25] Assessment of PV Module Durability Using Accelerated and Outdoor Performance Analysis and Comparisons
    Gambogi, William J.
    Heta, Yushi
    Kopchick, James G.
    Felder, Thomas
    MacMaster, Steven W.
    Bradley, Alexander Z.
    Hamzavytehrany, Babak
    Yu, Bao-Ling
    Stika, Katherine M.
    Trout, T. John
    Garreau-Iles, Lucie
    Fu, Oakland
    Hu, Hongjie
    2014 IEEE 40TH PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2014, : 2176 - 2181
  • [26] Thermal performance of unvented attics in hot-dry climates: Results from building America
    Hendron, R
    Farrar-Nagy, S
    Anderson, R
    Reeves, P
    Hancock, E
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (02): : 732 - 737
  • [27] Assessment of thermal performance of energy-active window systems in hot climates
    Magzoub, Mahmoud
    Mohammed, Mohammed Alhaji
    Budaiwi, Ismail M.
    Al-Homoud, Mohammad S.
    ENERGY AND BUILDINGS, 2024, 318
  • [28] Experimental Study of Cool Roof Impact on Building Performance in Hot-Dry and Dusty Climates
    Algarni, Salem A.
    INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES (IAQ 2020), PT 1, 2021,
  • [29] Analytical assessment of the outdoor performance and efficiency of grid-tied photovoltaic system under hot dry climate in the south of Algeria
    Necaibia, Ammar
    Bouraiou, Ahmed
    Ziane, Abderrezzaq
    Sahouane, Nordine
    Hassani, Samir
    Mostefaoui, Mohammed
    Dabou, Rachid
    Mouhadjer, Samir
    ENERGY CONVERSION AND MANAGEMENT, 2018, 171 : 778 - 786
  • [30] CFD-Optimized Radiant Cooling with Dedicated Outdoor Air System (DOAS) for High Ceilinged Spaces in Hot and Dry Climates
    Ghoussoub, Youssef
    Akhdar, Adnan
    THIRD INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN - MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2018, : 178 - 187