A validated SPME-GC-MS method for simultaneous quantification of club drugs in human urine

被引:71
|
作者
Brown, Stacy D. [1 ]
Rhodes, Daniel J. [1 ]
Pritchard, Boyd J. [1 ]
机构
[1] Citadel, Dept Chem, Charleston, SC 29409 USA
关键词
club drugs; SPME; GC-MS; validation;
D O I
10.1016/j.forsciint.2006.10.015
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
A solid-phase microextraction-gas chromatographic-mass spectrometric (SPME-GC-MS) method has been developed and validated for measuring four club drugs in human urine. These drugs include gamma-hydroxybutyrate (GHB), ketamine (KET), methamphetamine (MAMP), and methylenedioxyrnethamphetamine (MDMA). These drugs are referred to as 'club drugs' because of their prevalence at parties and raves. Deuterium labeled internal standards for each of the four drugs was included in the assay to aid in quantitation. The drugs were spiked into human urine and derivatized using pyridine and hexylchloroformate to make them suitable for GC-MS analysis. The SPME conditions of extraction time/temperature and desorption time/temperature were optimized to yield the highest peak area for each of the four drugs. The final SPME parameters included a 90 degrees C extraction for 20 min with a I min desorption in the GC injector at 225 degrees C using a splitless injection. All SPME work was done using a 100 mu m PDMS fiber by Supelco. The ratio of pyridine to hexylchloroformate for derivatization was also optimized. The GC separation was carried out on a VF-5ht column by Varian (30 m, 0.25 mm i.d., 0.10 mu m film thickness) using a temperature program of 150-270 degrees C at 10 degrees C/min. The instrument used was a ThermoFinnigan Trace GC-Polaris Q interfaced with a LEAP CombiPal autosampler. The data was collected by using extracted ion chromatograms of marker m/z values for each drug from the total ion chromatograms (TIC) (full scan mode). Calibration curves with R-2 > 0.99 were generated each day using the peak area ratios (peak area drug/peak area internal standard) versus concentration. The validated method resulted in intra-day and inter-day precision (% R. S.D.) of less than 15% and a % error of less than 15% for four concentrations in the range of 0.05-20 mu g/mL (MAMP) and 0.10-20 mu g/mL (GHB, KET, and MDMA). This method has the advantage of an easy sample preparation with acceptable accuracy and precision for the simultaneous quantification of these four drugs of abuse and shows no interference from the urine matrix. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:142 / 150
页数:9
相关论文
共 50 条
  • [1] Direct determination of anabolic steroids in pig urine by a new SPME-GC-MS method
    Zhang, Zhuomin
    Duan, Hongbin
    Zhang, Lan
    Chen, Xi
    Liu, Wei
    Chen, Guonan
    [J]. TALANTA, 2009, 78 (03) : 1083 - 1089
  • [2] Uncertainty in the quantification of pentachlorophenol in wood processing wastewaters by SPME-GC-MS
    I. Brás
    N. Ratola
    A. Alves
    [J]. Journal of Analytical Chemistry, 2011, 66 : 756 - 762
  • [3] Uncertainty in the quantification of pentachlorophenol in wood processing wastewaters by SPME-GC-MS
    Bras, I.
    Ratola, N.
    Alves, A.
    [J]. JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (08) : 756 - 762
  • [4] Identification and quantification of flavor compounds in birch syrup using SPME-GC-MS
    Lloyd, Steven
    van den Berg, Abby
    Grimm, Casey
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [5] Simultaneous quantification of ten cytotoxic drugs by a validated LC–ESI–MS/MS method
    Susanne Nussbaumer
    Sandrine Fleury-Souverain
    Paola Antinori
    Farshid Sadeghipour
    Denis F. Hochstrasser
    Pascal Bonnabry
    Jean-Luc Veuthey
    Laurent Geiser
    [J]. Analytical and Bioanalytical Chemistry, 2010, 398 : 3033 - 3042
  • [6] Method for the analysis of volatile compounds in virgin olive oil by SPME-GC-MS or SPME-GC-FID
    Aparicio-Ruiz, Ramon
    Casadei, Enrico
    Ortiz-Romero, Clemente
    Garcia-Gonzalez, Diego L.
    Servili, Maurizio
    Selvaggini, Roberto
    Lacoste, Florence
    Escobessa, Julien
    Vichi, Stefania
    Quintanilla-Casas, Beatriz
    Tres, Alba
    Golay, Pierre-Alain
    Lucci, Paolo
    Moret, Erica
    Valli, Enrico
    Bendini, Alessandra
    Toschi, Tullia Gallina
    [J]. METHODSX, 2023, 10
  • [7] Identification of odor biomarkers in irradiation injury urine based on headspace SPME-GC-MS
    Wu, Xin
    Zhu, Tong
    Zhang, Hongbing
    Lu, Lu
    He, Xin
    Liu, Changxiao
    Fan, Sai-jun
    [J]. INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2021, 97 (11) : 1597 - 1605
  • [8] A validated LC-MS/MS method for the quantification of climbazole metabolites in human urine
    Schmidtkunz, Christoph
    Küpper, Katja
    Gries, Wolfgang
    Leng, Gabriele
    [J]. Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences, 2021, 1173
  • [9] A validated LC-MS/MS method for the quantification of climbazole metabolites in human urine
    Schmidtkunz, Christoph
    Kuepper, Katja
    Gries, Wolfgang
    Leng, Gabriele
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1173
  • [10] Simultaneous quantification of ten cytotoxic drugs by a validated LC-ESI-MS/MS method
    Nussbaumer, Susanne
    Fleury-Souverain, Sandrine
    Antinori, Paola
    Sadeghipour, Farshid
    Hochstrasser, Denis F.
    Bonnabry, Pascal
    Veuthey, Jean-Luc
    Geiser, Laurent
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (7-8) : 3033 - 3042