Feasibility study of navigated endoscopy for the placement of high dose rate brachytherapy applicators in the esophagus and lung

被引:2
|
作者
Weersink, Robert A. [1 ,2 ,3 ,4 ]
Qiu, Jimmy [4 ]
Martinez, Diego [2 ]
Rink, Alexandra [1 ,2 ,4 ]
Borg, Jette [1 ,2 ]
Di Tomasso, Anne [2 ]
Irish, Jonathon C. [4 ,5 ]
Jaffray, David A. [1 ,2 ,3 ,4 ,6 ]
机构
[1] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5T 1P5, Canada
[2] Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON M5G 1X6, Canada
[3] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON M5S 3G9, Canada
[4] Univ Hlth Network, Techna Inst, Toronto, ON M5G 1L5, Canada
[5] Univ Toronto, Dept Surg Oncol, Toronto, ON M5T 1P5, Canada
[6] Univ Toronto, Dept Med Biophys, Toronto, ON M5G 1L7, Canada
基金
加拿大健康研究院;
关键词
brachytherapy; electromagnetic tracking; intraluminal applicators; ELECTROMAGNETIC TRACKING; CATHETER RECONSTRUCTION;
D O I
10.1002/mp.13997
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the electromagnetic (EM) tracking of endoscopes and applicators as a method of positioning a high dose rate (HDR) luminal applicator. Method An anatomical phantom consisting of a rigid trachea and flexible esophagus was used to compare applicator placement measurements using EM tracking vs the traditional method using two-dimensional (2D) fluoroscopy and surface skin markers. The phantom included a tumor in the esophagus and several pairs of optically visible points inside the lumen that were used to simulate proximal and distal ends of tumors of varying lengths. The esophagus tumor and lung points were visible on a computed tomography (CT) image of the phantom, which was used as ground truth for the measurements. The EM tracking system was registered to the CT image using fiducial markers. A flexible endoscope was tracked using the EM system and the locations of the proximal and distal ends of the tumor identified and this position recorded. An EM-tracked applicator was then inserted and positioned relative to the tumor markings. The applicator path was mapped using the EM tracking. The gross tumor length (GTL) and the distance between the first dwell position and distal edge of tumor (offset) were measured using the EM tracking and 2D fluoroscopy methods and compared to the same measurements on the CT image. Results The errors in GTL using EM tracking were on average -0.5 +/- 1.7 mm and 0.7 +/- 3.6 mm for esophagus and lung measurements, similar to errors measured using the 2D fluoroscopy method of -0.9 +/- 1.2 mm and 3.4 +/- 4.4 mm. Offset measurements were slightly larger while using EM tracking relative to the fluoroscopy method but these were not statistically significant. Conclusions Electromagnetic tracking for placement of lumen applicators is feasible and accurate. Tracking of the endoscope that is used to identify the proximal and distal ends of the tumor and of the applicator during insertion generates accurate three-dimensional measurements of the applicator path, GTL and offset. Guiding the placement of intraluminal applicators using EM navigation is potentially attractive for cases with complex insertions, such as those with nonlinear paths or multiple applicator insertions.
引用
收藏
页码:917 / 926
页数:10
相关论文
共 50 条
  • [31] TREATMENT OF SKIN CARCINOMAS BY VALENCIA APPLICATORS OF HIGH DOSE RATE BRACHYTHERAPY AND DERMOSCOPIC TUMORAL RESPONSE.
    Marin, A.
    Vargas-Diez, E.
    Cerezo, L.
    Garcia-Diez, A.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S225 - S225
  • [32] A linear source table for determination of treatment times for cylindrical applicators used for high dose rate brachytherapy
    Sahoo, N
    Sahoo, A
    MEDICAL PHYSICS, 2003, 30 (06) : 1332 - 1332
  • [33] Assessment of air pockets in high-dose-rate vaginal cuff brachytherapy using cylindrical applicators
    Hassouna, Ashraf
    Bahadur, Yasir Abdulaziz
    Constantinescu, Camelia
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2014, 6 (03) : 271 - 275
  • [34] Custom 3D-printed applicators for high dose-rate brachytherapy in skin cancer
    Membrive Conejo, Ismael
    Pera Cegarra, Oscar
    Foro Arnalot, Palmira
    Reig Castillejo, Ana
    Rodriguez de Dios, Nuria
    Sanz Latiesas, Xavier
    Pujol Vallverdu, Ramon M.
    Quera Jordana, Jaume
    Fernandez-Velilla Cepria, Enric
    Algara Munoz, Victor
    Algara Lopez, Manuel
    BRACHYTHERAPY, 2021, 20 (06) : 1257 - 1264
  • [35] USE OF CUSTOMIZED SURFACE APPLICATORS IN TREATING SKIN-LESIONS WITH HIGH-DOSE-RATE BRACHYTHERAPY
    PRESSER, JL
    SABBAS, A
    WONG, JR
    NISCE, LZ
    RUIZ, V
    AVANZATO, J
    RADIOLOGY, 1995, 197 : 188 - 188
  • [36] Navigated bronchoscopy and endobronchia-L ultrasound for brachytherapy of inoperable peripherail lung cancer: A feasibility study
    Becker, Heinrich D.
    Harms, Wolfgang
    CHEST, 2007, 132 (04) : 452S - 452S
  • [37] EM-Navigated Catheter Placement for Gynecologic Brachytherapy: An Accuracy Study
    Mehrtash, Alireza
    Damato, Antonio
    Pernelle, Guillaume
    Barber, Lauren
    Farhat, Nabgha
    Viswanathan, Akila
    Cormark, Robert
    Kapur, Tina
    MEDICAL IMAGING 2014: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2014, 9036
  • [38] Dosimetric characterization and feasibility testing for a new electronic high dose rate brachytherapy
    Rieke, JW
    Zaider, M
    Silvern, DA
    Rusch, TW
    Hansen, SD
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (01): : S592 - S592
  • [39] Investigation of obstructions in ring applicators during pulsed dose rate cervix brachytherapy
    Menon, G.
    Long, B.
    Petit, R.
    Zimmer, J.
    Gadbois, K.
    Niatsetski, Y.
    Wiebe, E.
    Cuartero, J.
    Huang, F.
    Yip, E.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S173 - S175
  • [40] Intraosseous High Dose Rate Brachytherapy (HDR) with Intramedullary Nailing for Long Bone Metastases - A Feasibility Study
    Gannavarapu, Bhavani
    Hassan-Rezaeian, Nima
    ONeill, David
    Hrycushko, Brian
    Folkert, Michael
    Callan, Alexandra
    Timmerman, Robert
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (02): : E53 - E53