Evaluation of low-volume plasma sampling for the analysis of meropenem in clinical samples

被引:7
|
作者
Parker, Suzanne L. [1 ]
Wallis, Steven C. [1 ]
Fourie, Cheryl [1 ,2 ]
Lassig-Smith, Melissa [2 ]
Starr, Therese [2 ]
Chikatamarla, Avinash [3 ]
Dorofaeff, Tavey [4 ]
Chatfield, Mark D. [1 ]
Lipman, Jeffrey [1 ,2 ,5 ]
Roberts, Jason A. [1 ,2 ,5 ,6 ]
机构
[1] Univ Queensland, UQ Ctr Clin Res, Brisbane, Qld, Australia
[2] Royal Brisbane & Womens Hosp, Dept Intens Care Med, Brisbane, Qld, Australia
[3] Univ Queensland, Fac Med, Brisbane, Qld, Australia
[4] Queensland Childrens Hosp, Dept Paediat Intens Care, Brisbane, Qld, Australia
[5] Univ Montpellier, Nimes Univ Hosp, Div Anaesthesiol Crit Care Emergency & Pain Med, Nimes, France
[6] Royal Brisbane & Womens Hosp, Dept Pharm, Brisbane, Qld, Australia
基金
英国医学研究理事会;
关键词
Antibiotic; Microsampling; Wing; Capillary; Meropenem;
D O I
10.1007/s00216-021-03851-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reducing the volume of blood sampled from neonatal or paediatric patients is important to facilitate research in a group that is under-represented in clinical studies. Not all patients have a cannula available for blood sampling, meaning there are real advantages in obtaining a blood microsample by skin prick. In this study, the results obtained from both capillary microsamples (CMS) and a microfluidic (MF)-CMS by skin prick are compared to conventional plasma sampled from an arterial catheter in a clinical bridging study. Six critically ill patients receiving meropenem were included with the incurred sample reanalysis test meeting the acceptance criteria for both CMS (n = 24 samples) and MF-CMS (n = 20 samples). Bland-Altman plots comparing MF-CMS to conventional arterial blood sampling revealed a difference of - 12.7 +/- 22.1% (mean +/- standard deviation (SD), and comparing CMS to conventional arterial blood sampling a difference of - 3.4 +/- 17.0%. At - 12.7%, the bias between MF-CMS and conventional sampling is greater than the bias found with CMS, although within the limit of acceptability for analytical accuracy (that being +/- 15%). Samples collected by skin prick and using CMS produced meropenem concentrations that were comparable to those obtained from conventional arterial catheter sampling. CMS samples were found to be stable when stored in the capillary tube for 24 h at 5 degrees C or for 4 h at room temperature.
引用
收藏
页码:2155 / 2162
页数:8
相关论文
共 50 条
  • [41] MULTICENTER CLINICAL-TRIAL OF LOW-VOLUME FRESH-FROZEN PLASMA THERAPY IN ACUTE-PANCREATITIS
    LEESE, T
    HOLLIDAY, M
    HEATH, D
    HALL, AW
    BELL, PRF
    BRITISH JOURNAL OF SURGERY, 1987, 74 (10) : 907 - 911
  • [42] Development of an HPLC-UV method for quantification of posaconazole in low-volume plasma samples: design of experiments and machine learning models
    Bayat, Fereshteh
    Baghi, Ali Hashemi
    Abbasian, Zahra
    Dadashzadeh, Simin
    Aboofazeli, Reza
    Haeri, Azadeh
    BMC CHEMISTRY, 2024, 18 (01)
  • [43] Sampling efficiency of low-volume PM10 inlets with different impaction substrates
    Thi-Cuc Le
    Shukla, Krishna Kumar
    Sung, Jung-Che
    Li, Ziyi
    Yeh, Huajun
    Huang, Wei
    Tsai, Chuen-Jinn
    AEROSOL SCIENCE AND TECHNOLOGY, 2019, 53 (03) : 295 - 308
  • [44] Evaluation of western coal fly ashes for stabilization of low-volume roads
    Turner, JP
    TESTING SOIL MIXED WITH WASTE OR RECYCLED MATERIALS, 1997, 1275 : 157 - 171
  • [45] Daily Low-Volume Paracentesis and Clinical Complications in Patients With Refractory Ascites
    Tergast, Tammo L.
    Griemsmann, Marie
    Stockhoff, Lena
    Port, Kerstin
    Heidrich, Benjamin
    Cornberg, Markus
    Wedemeyer, Heiner
    Lenzen, Henrike
    Richter, Nicolas
    Jaeckel, Elmar
    Maasoumy, Benjamin
    JAMA NETWORK OPEN, 2023, 6 (07) : E2322048
  • [46] Survival Analysis of Concrete Overlays on Low-Volume Roads in Iowa
    King, Daniel
    Taylor, Peter
    TRANSPORTATION RESEARCH RECORD, 2023,
  • [47] Evaluation of adjuvants for reducing the risk of phytotoxicity in low-volume spray of propiconazole
    Teng, Lijie
    Gao, Tuqiang
    Gu, Anyu
    Zhang, Qizhen
    Hu, Maolin
    Hao, Jianjun
    Li, Xiaolin
    Liu, Pengfei
    PHYTOPATHOLOGY RESEARCH, 2023, 5 (01)
  • [48] Role of transrectal ultrasonography in the evaluation of azoospermic men with low-volume ejaculate
    Raviv, Gil
    Mor, Yoram
    Levron, Jacob
    Shefi, Shai
    Zilberman, Dorit
    Ramon, Jacob
    Madgar, Igal
    JOURNAL OF ULTRASOUND IN MEDICINE, 2006, 25 (07) : 825 - 829
  • [49] Evaluation of adjuvants for reducing the risk of phytotoxicity in low-volume spray of propiconazole
    Lijie Teng
    Tuqiang Gao
    Anyu Gu
    Qizhen Zhang
    Maolin Hu
    Jianjun Hao
    Xiaolin Li
    Pengfei Liu
    Phytopathology Research, 5
  • [50] Speed Table Evaluation and Speed Modeling for Low-Volume Crosstown Roads
    Tsui Moreno, Ana
    Garcia, Alfredo
    Alfonso Romero, Mario
    TRANSPORTATION RESEARCH RECORD, 2011, (2203) : 85 - 93