Evaluation of low-volume plasma sampling for the analysis of meropenem in clinical samples

被引:7
|
作者
Parker, Suzanne L. [1 ]
Wallis, Steven C. [1 ]
Fourie, Cheryl [1 ,2 ]
Lassig-Smith, Melissa [2 ]
Starr, Therese [2 ]
Chikatamarla, Avinash [3 ]
Dorofaeff, Tavey [4 ]
Chatfield, Mark D. [1 ]
Lipman, Jeffrey [1 ,2 ,5 ]
Roberts, Jason A. [1 ,2 ,5 ,6 ]
机构
[1] Univ Queensland, UQ Ctr Clin Res, Brisbane, Qld, Australia
[2] Royal Brisbane & Womens Hosp, Dept Intens Care Med, Brisbane, Qld, Australia
[3] Univ Queensland, Fac Med, Brisbane, Qld, Australia
[4] Queensland Childrens Hosp, Dept Paediat Intens Care, Brisbane, Qld, Australia
[5] Univ Montpellier, Nimes Univ Hosp, Div Anaesthesiol Crit Care Emergency & Pain Med, Nimes, France
[6] Royal Brisbane & Womens Hosp, Dept Pharm, Brisbane, Qld, Australia
基金
英国医学研究理事会;
关键词
Antibiotic; Microsampling; Wing; Capillary; Meropenem;
D O I
10.1007/s00216-021-03851-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reducing the volume of blood sampled from neonatal or paediatric patients is important to facilitate research in a group that is under-represented in clinical studies. Not all patients have a cannula available for blood sampling, meaning there are real advantages in obtaining a blood microsample by skin prick. In this study, the results obtained from both capillary microsamples (CMS) and a microfluidic (MF)-CMS by skin prick are compared to conventional plasma sampled from an arterial catheter in a clinical bridging study. Six critically ill patients receiving meropenem were included with the incurred sample reanalysis test meeting the acceptance criteria for both CMS (n = 24 samples) and MF-CMS (n = 20 samples). Bland-Altman plots comparing MF-CMS to conventional arterial blood sampling revealed a difference of - 12.7 +/- 22.1% (mean +/- standard deviation (SD), and comparing CMS to conventional arterial blood sampling a difference of - 3.4 +/- 17.0%. At - 12.7%, the bias between MF-CMS and conventional sampling is greater than the bias found with CMS, although within the limit of acceptability for analytical accuracy (that being +/- 15%). Samples collected by skin prick and using CMS produced meropenem concentrations that were comparable to those obtained from conventional arterial catheter sampling. CMS samples were found to be stable when stored in the capillary tube for 24 h at 5 degrees C or for 4 h at room temperature.
引用
收藏
页码:2155 / 2162
页数:8
相关论文
共 50 条
  • [21] Sampling artifacts in measurement of elemental and organic carbon: Low-volume sampling in indoor and outdoor environments
    Olson, DA
    Norris, GA
    ATMOSPHERIC ENVIRONMENT, 2005, 39 (30) : 5437 - 5445
  • [22] Determination of trimethoprim in low-volume human plasma by liquid chromatography
    Hruska, MW
    Frye, RF
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 807 (02): : 301 - 305
  • [23] A new method for sampling low-volume AMCs in a front opening unified pod
    Kuo, Chi-Wen
    Chang, Luh-Maan
    MICROELECTRONIC ENGINEERING, 2016, 166 : 26 - 30
  • [24] A new technique for low-volume continuous sampling of spent dialysate: a validation study
    Rafael Bueno Orcy
    Maria Fernanda Antunes
    Jean Pierre Oses
    Maristela Böhlke
    Journal of Artificial Organs, 2019, 22 : 134 - 140
  • [25] A new technique for low-volume continuous sampling of spent dialysate: a validation study
    Orcy, Rafael Bueno
    Antunes, Maria Fernanda
    Oses, Jean Pierre
    Bohlke, Maristela
    JOURNAL OF ARTIFICIAL ORGANS, 2019, 22 (02) : 134 - 140
  • [26] A LOW-VOLUME AIR SAMPLING METHOD FOR BIOCIDES AND PCBS IN A MICRO-CHAMBER
    Mull, Birte
    Wiegner, Katharina
    Horn, Wolfgang
    FRESENIUS ENVIRONMENTAL BULLETIN, 2013, 22 (03): : 675 - 680
  • [27] Design and evaluation of a low-volume total suspended particulate sampler
    Wanjura, JD
    Parnell, CB
    Shaw, BW
    Lacey, RE
    TRANSACTIONS OF THE ASAE, 2005, 48 (04): : 1547 - 1552
  • [28] Quantitative Methods for Multielemental Analysis in Low-Volume Biofluids
    Chasse, John
    SPECTROSCOPY, 2021, 36 (02) : 38 - 40
  • [29] Indoor low-volume spray trials: Handheld equipment evaluation
    Brown, JR
    Williams, DC
    Gwinn, TA
    Presley, SH
    Beavers, GM
    JOURNAL OF THE AMERICAN MOSQUITO CONTROL ASSOCIATION, 2002, 18 (03) : 232 - 235
  • [30] Quantification of human papillomavirus cell-free DNA from low-volume blood plasma samples by digital PCR
    Rosing, Fabian
    Meier, Matthias
    Schroeder, Lea
    Laban, Simon
    Hoffmann, Thomas
    Kaufmann, Andreas
    Siefer, Oliver
    Wuerdemann, Nora
    Klussmann, Jens Peter
    Rieckmann, Thorsten
    Alt, Yvonne
    Faden, Daniel L.
    Waterboer, Tim
    Hoefler, Daniela
    MICROBIOLOGY SPECTRUM, 2024, 12 (07) : e0002424