Evaluation of low-volume plasma sampling for the analysis of meropenem in clinical samples

被引:7
|
作者
Parker, Suzanne L. [1 ]
Wallis, Steven C. [1 ]
Fourie, Cheryl [1 ,2 ]
Lassig-Smith, Melissa [2 ]
Starr, Therese [2 ]
Chikatamarla, Avinash [3 ]
Dorofaeff, Tavey [4 ]
Chatfield, Mark D. [1 ]
Lipman, Jeffrey [1 ,2 ,5 ]
Roberts, Jason A. [1 ,2 ,5 ,6 ]
机构
[1] Univ Queensland, UQ Ctr Clin Res, Brisbane, Qld, Australia
[2] Royal Brisbane & Womens Hosp, Dept Intens Care Med, Brisbane, Qld, Australia
[3] Univ Queensland, Fac Med, Brisbane, Qld, Australia
[4] Queensland Childrens Hosp, Dept Paediat Intens Care, Brisbane, Qld, Australia
[5] Univ Montpellier, Nimes Univ Hosp, Div Anaesthesiol Crit Care Emergency & Pain Med, Nimes, France
[6] Royal Brisbane & Womens Hosp, Dept Pharm, Brisbane, Qld, Australia
基金
英国医学研究理事会;
关键词
Antibiotic; Microsampling; Wing; Capillary; Meropenem;
D O I
10.1007/s00216-021-03851-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Reducing the volume of blood sampled from neonatal or paediatric patients is important to facilitate research in a group that is under-represented in clinical studies. Not all patients have a cannula available for blood sampling, meaning there are real advantages in obtaining a blood microsample by skin prick. In this study, the results obtained from both capillary microsamples (CMS) and a microfluidic (MF)-CMS by skin prick are compared to conventional plasma sampled from an arterial catheter in a clinical bridging study. Six critically ill patients receiving meropenem were included with the incurred sample reanalysis test meeting the acceptance criteria for both CMS (n = 24 samples) and MF-CMS (n = 20 samples). Bland-Altman plots comparing MF-CMS to conventional arterial blood sampling revealed a difference of - 12.7 +/- 22.1% (mean +/- standard deviation (SD), and comparing CMS to conventional arterial blood sampling a difference of - 3.4 +/- 17.0%. At - 12.7%, the bias between MF-CMS and conventional sampling is greater than the bias found with CMS, although within the limit of acceptability for analytical accuracy (that being +/- 15%). Samples collected by skin prick and using CMS produced meropenem concentrations that were comparable to those obtained from conventional arterial catheter sampling. CMS samples were found to be stable when stored in the capillary tube for 24 h at 5 degrees C or for 4 h at room temperature.
引用
收藏
页码:2155 / 2162
页数:8
相关论文
共 50 条
  • [1] Evaluation of low-volume plasma sampling for the analysis of meropenem in clinical samples
    Suzanne L. Parker
    Steven C. Wallis
    Cheryl Fourie
    Melissa Lassig-Smith
    Therese Starr
    Avinash Chikatamarla
    Tavey Dorofaeff
    Mark D. Chatfield
    Jeffrey Lipman
    Jason A. Roberts
    Analytical and Bioanalytical Chemistry, 2022, 414 : 2155 - 2162
  • [2] Gas chromatographic determination of midazolam in low-volume plasma samples
    Podkowik, BI
    Masur, S
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 681 (02): : 405 - 411
  • [3] COMPARATIVE-EVALUATION OF PROCEDURES FOR THE DETERMINATION OF PAH IN LOW-VOLUME SAMPLES
    SISOVIC, A
    FUGAS, M
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 1991, 18 (03) : 235 - 241
  • [4] DEVELOPMENT OF A LOW-VOLUME AEROSOL SAMPLING UNIT
    ARMBRUSTER, L
    HEJNY, H
    NIESSNER, R
    JOURNAL OF AEROSOL SCIENCE, 1986, 17 (03) : 546 - 546
  • [5] BURN RESUSCITATION WITH A LOW-VOLUME PLASMA REGIMEN - ANALYSIS OF MORTALITY
    AHARONI, A
    ABRAMOVICI, D
    WEINBERGER, M
    MOSCONA, R
    HIRSHOWITZ, B
    BURNS, 1989, 15 (04) : 230 - 232
  • [6] Evaluation of viscosity and surface tension of low-volume samples using glass capillary
    Sakamoto, Kenji
    Kobayashi, Koichiro
    Tabira, Keito
    Hachiya, Yuriko
    Ohno, Koki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (10)
  • [7] Validation of low-volume sampling devices for pharmacokinetic analysis: technical and logistical challenges and solutions
    Yang, Xiaoyun
    Williams, Kathi
    Elliott, Rebecca
    Hokom, Martha
    Allen, Janis
    Fischer, Saloumeh K.
    BIOANALYSIS, 2023, 15 (23) : 1407 - 1419
  • [8] Relative viscosity evaluation of low-volume samples using capillary flow under differential pressure
    Sakamoto, Kenji
    Okazaki, Nobumitsu
    Makino, Koji
    Osawa, Yukihiro
    Sanari, Nobuyuki
    Hachiya, Yuriko
    Ohno, Koki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2022, 61 (06)
  • [9] Diagnostic algorithm for low-volume CSF samples in tuberculous meningitis
    Singh, Sarman
    Sankar, Mani M.
    LANCET INFECTIOUS DISEASES, 2017, 17 (12): : 1236 - 1237
  • [10] A Direct Infusion Probe for Rapid Metabolomics of Low-Volume Samples
    Marques, Catia
    Liu, Liangwen
    Duncan, Kyle D.
    Lanekoff, Ingela
    ANALYTICAL CHEMISTRY, 2022, 94 (37) : 12875 - 12883