Effect of a Gel Retainment Dam on Automated Ultrasound Coverage in a Dual-Modality Breast Imaging System

被引:8
|
作者
Li, Jie [1 ,2 ]
Goodsitt, Mitchell M. [1 ]
Padilla, Frederic [1 ,3 ]
Fowlkes, J. Brian [1 ]
Hooi, Fong Ming [1 ]
Lashbrook, Christine R. [1 ]
Thomenius, Kai E. [4 ]
Carson, Paul L. [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Shandong Univ, Dept Ultrasound, Qilu Hosp, Jinan 250100, Peoples R China
[3] Univ Paris 06, CNRS, UMR 7623, Lab Imagerie Parametr, Paris, France
[4] GE Global Res, Niskayuna, NY USA
关键词
automated ultrasound; breast cancer screening; multi-modality; 3-dimensional imaging; MAMMOGRAPHY; CANCER; WOMEN; US; MASSES;
D O I
10.7863/jum.2010.29.7.1075
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The goal of this work was to evaluate a possible improvement in ultrasound coverage for a dual-modality breast imaging system in the mammographic geometry. Methods. A pilot study was performed to evaluate use of a rubber dam to retain ultrasound gel and improve imaging coverage at the breast periphery on a combined imaging system consisting of an ultrasound scanner and a digital x-ray tomosynthesis unit. Several dams were constructed to encompass the shapes of various sizes of compressed breasts. Visual tracings of the breast-to-paddle contact area and breast periphery were made for 8 breasts to estimate coverage area. Two readers independently reviewed the resulting images and were asked to rate the overall breast image quality. Results. The percentages of breast in contact with the paddle were greater (P < .01) and the linear dimensions of breast in contact with the paddle were larger (P < .05) with the rubber dam than without it. With the dam, the mean estimated area of the breast in contact with the paddle increased 14%, whereas the mean increase in the fraction of the total breast area in contact with paddle was 30%. The difference was due to the mean total projected area of the breast decreasing 12% as the dam was pressed against it. The image quality of automated ultrasound with the rubber dam was consistently judged to be superior to that without the dam. Conclusions. This method can enhance the absolute and percentage area of the breast in contact with the paddle, reducing noncontact gaps at the breast periphery. Gently pressing the breast periphery with the dam inserted toward the chest wall improves coverage in automated breast ultrasound scanning.
引用
收藏
页码:1075 / 1081
页数:7
相关论文
共 50 条
  • [41] Self-assembled microbubbles as contrast agents for ultrasound/magnetic resonance dual-modality imaging
    Song, Sheng
    Guo, Heze
    Jiang, Zequan
    Jin, Yuqing
    Wu, Ying
    An, Xiao
    Zhang, Zhaofeng
    Sun, Kang
    Dou, Hongjing
    ACTA BIOMATERIALIA, 2015, 24 : 266 - 278
  • [42] Methylene blue microbubbles as a model dual-modality contrast agent for ultrasound and activatable photoacoustic imaging
    Jeon, Mansik
    Song, Wentao
    Huynh, Elizabeth
    Kim, Jungho
    Kim, Jeesu
    Helfield, Brandon L.
    Leung, Ben Y. C.
    Goertz, David E.
    Zheng, Gang
    Oh, Jungtaek
    Lovell, Jonathan F.
    Kim, Chulhong
    JOURNAL OF BIOMEDICAL OPTICS, 2014, 19 (01)
  • [43] Rational Design of Magnetic Nanorattles as Contrast Agents for Ultrasound/Magnetic Resonance Dual-Modality Imaging
    Yang, Peng
    Wang, Fang
    Luo, Xianfu
    Zhang, Yuting
    Guo, Jia
    Sho, Weibin
    Wang, Changchun
    ACS APPLIED MATERIALS & INTERFACES, 2014, 6 (15) : 12581 - 12587
  • [44] Ultrasound/SPECT dual-modality imaging platform using 99mTc-labeled microbubbles
    Lazarova, Neva
    Causey, Patrick
    Foster, F. Stuart
    Harasiewicz, Kasia
    Manouchehhri, Shirin
    Valliant, John
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [45] Quantification and Depth Resolution of Lipid Core Plaques by Intravascular Photoacoustic and Ultrasound Dual-Modality Imaging
    Kole, Ayeeshik
    Cao, Yingchun
    Hui, Jie
    Bolad, Islam
    Alloosh, Mouhamad
    Cheng, Ji-Xin
    Sturek, Michael
    JACC-CARDIOVASCULAR INTERVENTIONS, 2018, 11 (04) : S37 - S38
  • [46] A Dual-Modality Probe Utilizing Intravascular Ultrasound and Optical Coherence Tomography for Intravascular Imaging Applications
    Yang, Hao-Chung
    Yin, Jiechen
    Hu, Changhong
    Cannata, Jonathan
    Zhou, Qifa
    Zhang, Jun
    Chen, Zhongping
    Shung, K. Kirk
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (12) : 2839 - 2843
  • [47] A digital x-ray tomosynthesis coupled near infrared spectral tomography system for dual-modality breast imaging
    Krishnaswamy, Venkataramanan
    Michaelsen, Kelly E.
    Pogue, Brian W.
    Poplack, Steven P.
    Shaw, Ian
    Defrietas, Ken
    Brooks, Ken
    Paulsen, Keith D.
    OPTICS EXPRESS, 2012, 20 (17): : 19125 - 19136
  • [48] Sentinel lymph node mapping in patients with breast cancer using a photoacoustic/ultrasound dual-modality imaging system with carbon nanoparticles as the contrast agent: a pilot study
    Gu, Liujie
    Deng, Handi
    Bai, Yizhou
    Gao, Jianpan
    Wang, Xuewei
    Yue, Tong
    Luo, Bin
    Ma, Cheng
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (03) : 1003 - 1014
  • [49] Real-time photoacoustic and ultrasound dual-modality imaging system facilitated with graphics processing unit and code parallel optimization
    Yuan, Jie
    Xu, Guan
    Yu, Yao
    Zhou, Yu
    Carson, Paul L.
    Wang, Xueding
    Liu, Xiaojun
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (08)
  • [50] Image processing and analysis in a dual-modality optoacoustic/ultrasonic system for breast cancer diagnosis
    Nadvoretskiy, Vyacheslav
    Ermilov, Sergey
    Brecht, Hans-Peter
    Su, Richard
    Oraevsky, Alexander
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2011, 2011, 7899