Effect of a Gel Retainment Dam on Automated Ultrasound Coverage in a Dual-Modality Breast Imaging System

被引:8
|
作者
Li, Jie [1 ,2 ]
Goodsitt, Mitchell M. [1 ]
Padilla, Frederic [1 ,3 ]
Fowlkes, J. Brian [1 ]
Hooi, Fong Ming [1 ]
Lashbrook, Christine R. [1 ]
Thomenius, Kai E. [4 ]
Carson, Paul L. [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Shandong Univ, Dept Ultrasound, Qilu Hosp, Jinan 250100, Peoples R China
[3] Univ Paris 06, CNRS, UMR 7623, Lab Imagerie Parametr, Paris, France
[4] GE Global Res, Niskayuna, NY USA
关键词
automated ultrasound; breast cancer screening; multi-modality; 3-dimensional imaging; MAMMOGRAPHY; CANCER; WOMEN; US; MASSES;
D O I
10.7863/jum.2010.29.7.1075
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The goal of this work was to evaluate a possible improvement in ultrasound coverage for a dual-modality breast imaging system in the mammographic geometry. Methods. A pilot study was performed to evaluate use of a rubber dam to retain ultrasound gel and improve imaging coverage at the breast periphery on a combined imaging system consisting of an ultrasound scanner and a digital x-ray tomosynthesis unit. Several dams were constructed to encompass the shapes of various sizes of compressed breasts. Visual tracings of the breast-to-paddle contact area and breast periphery were made for 8 breasts to estimate coverage area. Two readers independently reviewed the resulting images and were asked to rate the overall breast image quality. Results. The percentages of breast in contact with the paddle were greater (P < .01) and the linear dimensions of breast in contact with the paddle were larger (P < .05) with the rubber dam than without it. With the dam, the mean estimated area of the breast in contact with the paddle increased 14%, whereas the mean increase in the fraction of the total breast area in contact with paddle was 30%. The difference was due to the mean total projected area of the breast decreasing 12% as the dam was pressed against it. The image quality of automated ultrasound with the rubber dam was consistently judged to be superior to that without the dam. Conclusions. This method can enhance the absolute and percentage area of the breast in contact with the paddle, reducing noncontact gaps at the breast periphery. Gently pressing the breast periphery with the dam inserted toward the chest wall improves coverage in automated breast ultrasound scanning.
引用
收藏
页码:1075 / 1081
页数:7
相关论文
共 50 条
  • [21] Miniature all-optical probe for photoacoustic and ultrasound dual-modality imaging
    Li, Guangyao
    Guo, Zhendong
    Chen, Sung-Liang
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494
  • [22] Copper oxide nanoparticles as contrast agents for MRI and ultrasound dual-modality imaging
    Perlman, Or
    Weitz, Iris S.
    Azhari, Haim
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (15): : 5767 - 5783
  • [23] Handheld dual-modality ultrasound and photoacoustic imaging for in vivo determination of melanoma depth
    Tripathi, S. V.
    Zhou, Y.
    Linette, G. P.
    Rosman, I. S.
    Council, M.
    Fields, R. C.
    Wang, L. V.
    Cornelius, L.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2016, 136 (05) : S107 - S107
  • [24] In Vivo Assessment of Hypoxia Levels in Pancreatic Tumors Using a Dual-Modality Ultrasound/Photoacoustic Imaging System
    Wang, Yuhling
    Jhang, De-Fu
    Tsai, Chia-Hua
    Chiang, Nai-Jung
    Tsao, Chia-Hui
    Chuang, Chiung-Cheng
    Chen, Li-Tzong
    Chang, Wun-Shaing Wayne
    Liao, Lun-De
    MICROMACHINES, 2021, 12 (06)
  • [25] Development of a novel, dual-modality image guidance system by combining a focussed gamma probe with ultrasound imaging
    Wilson, Sydney L. M.
    Park, Claire K.
    Barker, Kevin
    Bax, Jeffrey
    Nikolov, Hristo N.
    Fenster, Aaron
    Holdsworth, David W.
    MEDICAL IMAGING 2022: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2022, 12034
  • [26] Interpretation Times in Dual Modality Breast Imaging Using Automated Ultrasound With Digital Tomosynthesis Mammography
    Roubidoux, M.
    Jeffries, D.
    Joe, A.
    Klein, K.
    Pinsky, R.
    Patterson, S.
    Sinha, S.
    Hadjiiski, L.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [27] Albumin-based nanoparticle for dual-modality imaging of the lymphatic system
    Li, Mingze
    Zhang, Yundong
    Ma, Jinli
    Du, Jianshi
    RSC ADVANCES, 2023, 13 (04) : 2248 - 2255
  • [28] Pilot Patient Studies Using a Dedicated Dual-Modality SPECT-CT System for Breast Imaging
    Madhav, P.
    Cutler, S.
    Crotty, D.
    Perez, K.
    McKinley, R.
    Marcom, P.
    Wong, T.
    Tornai, M.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [29] Preclinical detection of liver fibrosis using dual-modality photoacoustic/ultrasound system
    van den Berg, Pim J.
    Bansal, Ruchi
    Daoudi, Khalid
    Steenbergen, Wiendelt
    Prakash, Jai
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (12): : 5081 - 5091
  • [30] A Dual-Modality Photoacoustic and Ultrasound Imaging System for Noninvasive Sentinel Lymph Node Detection: Preliminary Clinical Results
    Erpelding, Todd N.
    Garcia-Uribe, Alejandro
    Krumholz, Arie
    Ke, Haixin
    Maslov, Konstantin
    Appleton, Catherine
    Margenthaler, Julie
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014, 2014, 8943