Effect of a Gel Retainment Dam on Automated Ultrasound Coverage in a Dual-Modality Breast Imaging System

被引:8
|
作者
Li, Jie [1 ,2 ]
Goodsitt, Mitchell M. [1 ]
Padilla, Frederic [1 ,3 ]
Fowlkes, J. Brian [1 ]
Hooi, Fong Ming [1 ]
Lashbrook, Christine R. [1 ]
Thomenius, Kai E. [4 ]
Carson, Paul L. [1 ]
机构
[1] Univ Michigan Hlth Syst, Dept Radiol, Ann Arbor, MI 48109 USA
[2] Shandong Univ, Dept Ultrasound, Qilu Hosp, Jinan 250100, Peoples R China
[3] Univ Paris 06, CNRS, UMR 7623, Lab Imagerie Parametr, Paris, France
[4] GE Global Res, Niskayuna, NY USA
关键词
automated ultrasound; breast cancer screening; multi-modality; 3-dimensional imaging; MAMMOGRAPHY; CANCER; WOMEN; US; MASSES;
D O I
10.7863/jum.2010.29.7.1075
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective. The goal of this work was to evaluate a possible improvement in ultrasound coverage for a dual-modality breast imaging system in the mammographic geometry. Methods. A pilot study was performed to evaluate use of a rubber dam to retain ultrasound gel and improve imaging coverage at the breast periphery on a combined imaging system consisting of an ultrasound scanner and a digital x-ray tomosynthesis unit. Several dams were constructed to encompass the shapes of various sizes of compressed breasts. Visual tracings of the breast-to-paddle contact area and breast periphery were made for 8 breasts to estimate coverage area. Two readers independently reviewed the resulting images and were asked to rate the overall breast image quality. Results. The percentages of breast in contact with the paddle were greater (P < .01) and the linear dimensions of breast in contact with the paddle were larger (P < .05) with the rubber dam than without it. With the dam, the mean estimated area of the breast in contact with the paddle increased 14%, whereas the mean increase in the fraction of the total breast area in contact with paddle was 30%. The difference was due to the mean total projected area of the breast decreasing 12% as the dam was pressed against it. The image quality of automated ultrasound with the rubber dam was consistently judged to be superior to that without the dam. Conclusions. This method can enhance the absolute and percentage area of the breast in contact with the paddle, reducing noncontact gaps at the breast periphery. Gently pressing the breast periphery with the dam inserted toward the chest wall improves coverage in automated breast ultrasound scanning.
引用
收藏
页码:1075 / 1081
页数:7
相关论文
共 50 条
  • [1] Automated ultrasound scanning on a dual-modality breast imaging system - Coverage and motion issues and solutions
    Sinha, Sumedha P.
    Goodsitt, Mitchell M.
    Roubidoux, Marilyn A.
    Booi, Rebecca C.
    LeCarpentier, Gerald L.
    Lashbrook, Christine R.
    Thomenius, Kai E.
    Chalek, Carl L.
    Carson, Paul L.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (05) : 645 - 655
  • [2] Dual-modality section imaging system with optical ultrasound detection for photoacoustic and ultrasound imaging
    Nuster, Robert
    Wurzinger, Gerhild
    Gratt, Sibylle
    Paltauf, Guenther
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2013, 2013, 8581
  • [3] Dual-modality PET/ultrasound imaging of the prostate
    Huber, J. S.
    Moses, W. W.
    Pouliot, J.
    Hsu, I. C.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2187 - 2190
  • [4] Testing a dual-Modality system that combines full-field digital mammography and automated breast ultrasound
    Vaughan, Christopher L.
    Douglas, Tania S.
    Said-Hartley, Qonita
    Baasch, Roland V.
    Boonzaier, James A.
    Goemans, Brian C.
    Harverson, John
    Mingay, Michael W.
    Omar, Shuaib
    Smith, Raphael V.
    Venter, Nielen C.
    Wilson, Heidi S.
    CLINICAL IMAGING, 2016, 40 (03) : 498 - 505
  • [5] Photoacoustic and Ultrasound Dual-modality Imaging for Inflammatory Arthritis
    Xu, Guan
    Chamberland, David
    Girish, Gandikota
    Wang, Xueding
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS X, 2014, 8926
  • [6] Optimal probe design for dual-modality breast imaging
    Xu, Chen
    Zhu, Quing
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE VII, 2007, 6434
  • [7] Dual-Modality Photoacoustic and Ultrasound Imaging System for Noninvasive Sentinel Lymph Node Detection in Patients with Breast Cancer
    Alejandro Garcia-Uribe
    Todd N. Erpelding
    Arie Krumholz
    Haixin Ke
    Konstantin Maslov
    Catherine Appleton
    Julie A. Margenthaler
    Lihong V. Wang
    Scientific Reports, 5
  • [8] Dual-Modality Photoacoustic and Ultrasound Imaging System for Noninvasive Sentinel Lymph Node Detection in Patients with Breast Cancer
    Garcia-Uribe, Alejandro
    Erpelding, Todd N.
    Krumholz, Arie
    Ke, Haixin
    Maslov, Konstantin
    Appleton, Catherine
    Margenthaler, Julie A.
    Wang, Lihong V.
    SCIENTIFIC REPORTS, 2015, 5
  • [9] Dual-modality imaging with a ultrasound-gamma device for oncology
    Polito, C.
    Pellegrini, R.
    Cinti, M. N.
    De Vincentis, G.
    Lo Meo, S.
    Fabbri, A.
    Bennati, P.
    Cencelli, V. Orsolini
    Pani, R.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 147 : 77 - 84
  • [10] Photoacoustic and ultrasound dual-modality imaging of human peripheral joints
    Xu, Guan
    Rajian, Justin R.
    Girish, Gandikota
    Kaplan, Mariana J.
    Fowlkes, J. Brian
    Carson, Paul L.
    Wang, Xueding
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (01)