Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis System

被引:11
|
作者
Hsu, Chia-Yu [1 ,2 ]
Tsai, Yuh-Show [2 ]
Yau, Cheng-Shiang [2 ]
Shie, Hung-Hai [3 ]
Wu, Chu-Ming [1 ]
机构
[1] Ten Chan Gen Hosp, Dept Rehabil Med, 155 Yanping Rd, Taoyuan 320, Taiwan
[2] Chung Yuan Christian Univ, Dept Biomed Engn, 200 Zhongbei Rd, Taoyuan 320, Taiwan
[3] Ten Chan Gen Hosp, Dept Physiotherapy, 155 Yanping Rd, Taoyuan 320, Taiwan
关键词
accelerometry; gait; infrared; trunk acceleration; reliability; MINIMAL DETECTABLE CHANGE; ELDERLY-PEOPLE; HUMAN WALKING; ACCELERATION; PARAMETERS; DISORDERS; PREVALENCE; LOCATIONS; RECOVERY; DISEASE;
D O I
10.3390/s16081156
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study was to determine the test-retest reliability of an automated infrared-assisted, trunk accelerometer-based gait analysis system for measuring gait parameters of healthy subjects in a hospital. Thirty-five participants (28 of them females; age range, 23-79 years) performed a 5-m walk twice using an accelerometer-based gait analysis system with infrared assist. Measurements of spatiotemporal gait parameters (walking speed, step length, and cadence) and trunk control (gait symmetry, gait regularity, acceleration root mean square (RMS), and acceleration root mean square ratio (RMSR)) were recorded in two separate walking tests conducted 1 week apart. Relative and absolute test-retest reliability was determined by calculating the intra-class correlation coefficient (ICC3,1) and smallest detectable difference (SDD), respectively. The test-retest reliability was excellent for walking speed (ICC = 0.87, 95% confidence interval = 0.74-0.93, SDD = 13.4%), step length (ICC = 0.81, 95% confidence interval = 0.63-0.91, SDD = 12.2%), cadence (ICC = 0.81, 95% confidence interval = 0.63-0.91, SDD = 10.8%), and trunk control (step and stride regularity in anterior-posterior direction, acceleration RMS and acceleration RMSR in medial-lateral direction, and acceleration RMS and stride regularity in vertical direction). An automated infrared-assisted, trunk accelerometer-based gait analysis system is a reliable tool for measuring gait parameters in the hospital environment.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Design of a Machine Learning-Assisted Wearable Accelerometer-Based Automated System for Studying the Effect of Dopaminergic Medicine on Gait Characteristics of Parkinson's Patients
    Aich, Satyabrata
    Pradhan, Pyari Mohan
    Chakraborty, Sabyasachi
    Kim, Hee-Cheol
    Kim, Hee-Tae
    Lee, Hae-Gu
    Kim, Il Hwan
    Joo, Moon-il
    Jong Seong, Sim
    Park, Jinse
    JOURNAL OF HEALTHCARE ENGINEERING, 2020, 2020
  • [32] Accuracy, concurrent validity, and test-retest reliability of pressure-based insoles for gait measurement in chronic stroke patients
    Neumann, Saskia
    Bauer, Christoph M.
    Nastasi, Luca
    Laderach, Julia
    Thurlimann, Eva
    Schwarz, Anne
    Held, Jeremia P. O.
    Easthope, Chris A.
    FRONTIERS IN DIGITAL HEALTH, 2024, 6
  • [33] Test-retest reliability of three dimensional gait analysis: Including a novel approach to visualising agreement of gait cycle waveforms with Bland and Altman plots
    Meldrum, Dara
    Shouldice, Ciara
    Conroy, Ronan
    Jones, Kim
    Forward, Malcolm
    GAIT & POSTURE, 2014, 39 (01) : 265 - 271
  • [34] The Ottawa Paramedic Physical Ability Test: test-retest reliability and analysis of sex-based performance differences
    Armstrong, Daniel P.
    Sinden, Kathryn E.
    Sendsen, Jonathan
    MacPhee, Renee S.
    Fischer, Steven L.
    ERGONOMICS, 2019, 62 (08) : 1033 - 1042
  • [35] Test-retest reliability and longitudinal analysis of automated hippocampal subregion volumes in healthy ageing and Alzheimer's disease populations
    Worker, Amanda
    Dima, Danai
    Combes, Anna
    Crum, William R.
    Streffer, Johannes
    Einstein, Steven
    Mehta, Mitul A.
    Barker, Gareth J.
    Williams, Steve C. R.
    O'daly, Owen
    HUMAN BRAIN MAPPING, 2018, 39 (04) : 1743 - 1754
  • [36] Test-retest reliability and minimal detectable change of three-dimensional gait analysis in chronic low back pain patients
    Fernandes, Rita
    Armada-da-Silva, Paulo
    Pool-Goudaazward, Annelies
    Moniz-Pereira, Vera
    Veloso, Antonio P.
    GAIT & POSTURE, 2015, 42 (04) : 491 - 497
  • [37] Test-Retest Reliability of Kinematic and Temporal Outcome Measures for Clinical Gait and Stair Walking Tests, Based on Wearable Inertial Sensors
    Nilsson, Sofie
    Ertzgaard, Per
    Lundgren, Mikael
    Grip, Helena
    SENSORS, 2022, 22 (03)
  • [38] A shoe sole-based apparatus and method for randomly perturbing the stance phase of gait: Test-retest reliability in young adults
    Kim, Hogene
    Ashton-Miller, James A.
    JOURNAL OF BIOMECHANICS, 2012, 45 (10) : 1850 - 1853
  • [39] Test-retest reliability analysis of the Cambridge Neuropsychological Automated Tests for the assessment of dementia in older people living in retirement homes
    Goncalves, Marta Matos
    Pinho, Maria Salome
    Simoes, Mario R.
    APPLIED NEUROPSYCHOLOGY-ADULT, 2016, 23 (04) : 251 - 263
  • [40] Three dimensional multi -segmental trunk kinematics and kinetics during gait: Test-retest reliability and minimal detectable change (vol 46, pg 18, 2016)
    Fernandes, Rita S.
    Armada-da-Silva, Paulo
    Pool-Goudzwaard, Annelies L.
    Moniz-Pereira, Vera
    Veloso, Antonio P.
    GAIT & POSTURE, 2016, 48 : 267 - 267