Test-Retest Reliability of an Automated Infrared-Assisted Trunk Accelerometer-Based Gait Analysis System

被引:11
|
作者
Hsu, Chia-Yu [1 ,2 ]
Tsai, Yuh-Show [2 ]
Yau, Cheng-Shiang [2 ]
Shie, Hung-Hai [3 ]
Wu, Chu-Ming [1 ]
机构
[1] Ten Chan Gen Hosp, Dept Rehabil Med, 155 Yanping Rd, Taoyuan 320, Taiwan
[2] Chung Yuan Christian Univ, Dept Biomed Engn, 200 Zhongbei Rd, Taoyuan 320, Taiwan
[3] Ten Chan Gen Hosp, Dept Physiotherapy, 155 Yanping Rd, Taoyuan 320, Taiwan
关键词
accelerometry; gait; infrared; trunk acceleration; reliability; MINIMAL DETECTABLE CHANGE; ELDERLY-PEOPLE; HUMAN WALKING; ACCELERATION; PARAMETERS; DISORDERS; PREVALENCE; LOCATIONS; RECOVERY; DISEASE;
D O I
10.3390/s16081156
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this study was to determine the test-retest reliability of an automated infrared-assisted, trunk accelerometer-based gait analysis system for measuring gait parameters of healthy subjects in a hospital. Thirty-five participants (28 of them females; age range, 23-79 years) performed a 5-m walk twice using an accelerometer-based gait analysis system with infrared assist. Measurements of spatiotemporal gait parameters (walking speed, step length, and cadence) and trunk control (gait symmetry, gait regularity, acceleration root mean square (RMS), and acceleration root mean square ratio (RMSR)) were recorded in two separate walking tests conducted 1 week apart. Relative and absolute test-retest reliability was determined by calculating the intra-class correlation coefficient (ICC3,1) and smallest detectable difference (SDD), respectively. The test-retest reliability was excellent for walking speed (ICC = 0.87, 95% confidence interval = 0.74-0.93, SDD = 13.4%), step length (ICC = 0.81, 95% confidence interval = 0.63-0.91, SDD = 12.2%), cadence (ICC = 0.81, 95% confidence interval = 0.63-0.91, SDD = 10.8%), and trunk control (step and stride regularity in anterior-posterior direction, acceleration RMS and acceleration RMSR in medial-lateral direction, and acceleration RMS and stride regularity in vertical direction). An automated infrared-assisted, trunk accelerometer-based gait analysis system is a reliable tool for measuring gait parameters in the hospital environment.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Within-day test-retest reliability of an accelerometer-based method for registration of step time symmetry during stair descent after ACL reconstruction and in healthy subjects
    Vervaat, Willemijn
    Bogen, Bard
    Moe-Nilssen, Rolf
    PHYSIOTHERAPY THEORY AND PRACTICE, 2022, 38 (01) : 226 - 234
  • [22] Evaluation of a smartphone accelerometer system for measuring nonlinear dynamics during treadmill walking: Concurrent validity and test-retest reliability
    Di Bacco, Vincenzo E.
    Gage, William H.
    JOURNAL OF BIOMECHANICS, 2023, 151
  • [23] Markerless three-dimensional gait analysis in healthy older adults: test-retest reliability and measurement error
    Carvalho, Andreia
    Vanrenterghem, Jos
    Cabral, Silvia
    Assuncao, Ana
    Fernandes, Rita
    Veloso, Antonio P.
    Moniz-Pereira, Vera
    JOURNAL OF BIOMECHANICS, 2024, 174
  • [24] Test-retest reliability and minimal detectable change for measures of wearable gait analysis system (G-walk) in children with cerebral palsy
    Yazici, Melek Volkan
    Cobanoglu, Gamze
    Yazici, Gokhan
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2022, 52 (03) : 658 - 666
  • [25] Test-Retest, Inter-Rater and Intra-Rater Reliability for Spatiotemporal Gait Parameters Using SANE (an eaSy gAit aNalysis systEm) as Measuring Instrument
    Chaparro-Rico, Betsy D. M.
    Cafolla, Daniele
    APPLIED SCIENCES-BASEL, 2020, 10 (17):
  • [26] Test-retest reliability of the prefrontal response to affective pictures based on functional near-infrared spectroscopy
    Huang, Yuxia
    Mao, Mengchai
    Zhang, Zong
    Zhou, Hui
    Zhao, Yang
    Duan, Lian
    Kreplin, Ute
    Xiao, Xiang
    Zhu, Chaozhe
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (01)
  • [27] Reliability of a standardized reading chart system:: variance component analysis, test-retest and inter-chart reliability
    Stifter, E
    König, F
    Lang, T
    Bauer, P
    Richter-Müksch, S
    Velikay-Parel, M
    Radner, W
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2004, 242 (01) : 31 - 39
  • [28] Reliability of a standardized reading chart system: variance component analysis, test-retest and inter-chart reliability
    Eva Stifter
    Franz König
    Thomas Lang
    Peter Bauer
    Sibylla Richter-Müksch
    Michaela Velikay-Parel
    Wolfgang Radner
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2004, 242 : 31 - 39
  • [29] The Coefficient of Variation of Step Time Can Overestimate Gait Abnormality: Test-Retest Reliability of Gait-Related Parameters Obtained with a Tri-Axial Accelerometer in Healthy Subjects
    Fujiwara, Shunrou
    Sato, Shinpei
    Sugawara, Atsushi
    Nishikawa, Yasumasa
    Koji, Takahiro
    Nishimura, Yukihide
    Ogasawara, Kuniaki
    SENSORS, 2020, 20 (03)
  • [30] Test-retest reliability and descriptive statistics of geometric measurements based on plantar pressure measurements in a healthy population during gait
    Akins, Jonathan S.
    Keenan, Karen A.
    Sell, Timothy C.
    Abt, John P.
    Lephart, Scott M.
    GAIT & POSTURE, 2012, 35 (01) : 167 - 169