Simple and robust saturation-based slice selection for ultrashort echo time MRI

被引:5
|
作者
Harkins, Kevin D. [1 ]
Horch, R. Adam [1 ,2 ]
Does, Mark D. [1 ,2 ,3 ,4 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Biomed Engn, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Radiol & Radiol Sci, Nashville, TN 37235 USA
[4] Vanderbilt Univ, Elect Engn, Nashville, TN 37235 USA
关键词
ultrashort echo time; UTE; slice selective; saturation; 2D; PULSE SEQUENCES; T-2; RELAXATION; EDDY CURRENTS; RF PULSES; COMPENSATION; EXCITATION; DESIGN; KERNEL; TISSUE;
D O I
10.1002/mrm.25361
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo present a new method for localizing signal within a two-dimensional (2D) slice suitable for ultrashort echo time (UTE) imaging, called saturation-based UTE (sat-UTE). The new method digitally subtracts two acquisitions that are nonselectively excited with and without selective saturation of the slice of interest. MethodsSat-UTE was compared with half-pulse and double-half pulse excited UTE within phantoms, as well as 3D-UTE within ex vivo femur and in vivo tibia. Numerical simulations were also used to quantify the effects of slice profile broadening and signal component amplitudes for quantitative UTE. ResultsSat-UTE is robust to suppress out-of-slice signal, and produces short T-2 signal decay curves comparable to 3D-UTE, but has a lower signal to noise ratio efficiency compared with other slice-selective methods. ConclusionThe proposed method is useful for fast, quantitative evaluation of short T-2 signals, and is insensitive to gradient performance. Magn Reson Med 73:2204-2211, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
下载
收藏
页码:2204 / 2211
页数:8
相关论文
共 50 条
  • [41] Quantification of Neonatal Lung Parenchymal Density via Ultrashort Echo Time MRI With Comparison to CT
    Higano, Nara S.
    Fleck, Robert J.
    Spielberg, David R.
    Walkup, Laura L.
    Hahn, Andrew D.
    Thomen, Robert P.
    Merhar, Stephanie L.
    Kingma, Paul S.
    Tkach, Jean A.
    Fain, Sean B.
    Woods, Jason C.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (04) : 992 - 1000
  • [42] Ultrashort Echo Time MRI of Cortical Bone at 7 Tesla Field Strength: A Feasibility Study
    Krug, Roland
    Larson, Peder Eric Zufall
    Wang, Chunsheng
    Burghardt, Andrew J.
    Kelley, Douglas A. C.
    Link, Thomas M.
    Zhang, Xiaoliang
    Vigneron, Daniel B.
    Majumdar, Sharmila
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (03) : 691 - 695
  • [43] Ultrashort Echo Time for Improved Positive-Contrast Manganese-Enhanced MRI of Cancer
    Nofiele, Joris Tchouala
    Cheng, Hai-Ling Margaret
    PLOS ONE, 2013, 8 (03):
  • [44] Detecting small pulmonary nodules with spiral ultrashort echo time sequences in 1.5 T MRI
    Yu-Sen Huang
    Emi Niisato
    Mao-Yuan Marine Su
    Thomas Benkert
    Hsao-Hsun Hsu
    Jin-Yuan Shih
    Jin-Shing Chen
    Yeun-Chung Chang
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2021, 34 : 399 - 409
  • [45] Three-dimensional Ultrashort Echo Time MRI for Functional Lung Imaging in Cystic Fibrosis
    Heidenreich, Julius F.
    Weng, Andreas M.
    Metz, Corona
    Benkert, Thomas
    Pfeuffer, Josef
    Hebestreit, Helge
    Bley, Thorsten A.
    Kostler, Herbert
    Veldhoen, Simon
    RADIOLOGY, 2020, 296 (01) : 191 - 199
  • [46] A computational measurement of cartilaginous endplate structure using ultrashort time-to-echo MRI scanning
    Jin, Ri-Chu
    Huang, Yong-Can
    Luk, Keith D. K.
    Hu, Yong
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2017, 143 : 49 - 58
  • [47] Assessment of iron nanoparticle distribution in mouse models using ultrashort-echo-time MRI
    Boss, Andreas
    Heeb, Laura
    Vats, Divya
    Starsich, Fabian H. L.
    Balfourier, Alice
    Herrmann, Inge K.
    Gupta, Anurag
    NMR IN BIOMEDICINE, 2022, 35 (06)
  • [48] Bright ultrashort echo time SWIFT MRI signal at the osteochondral junction is not located in the calcified cartilage
    Nykanen, Olli
    Leskinen, Henri P. P.
    Finnila, Mikko A. J.
    Karhula, Sakari S.
    Turunen, Mikael J.
    Toyras, Juha
    Saarakkala, Simo
    Nissi, Mikko J.
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2020, 38 (12) : 2649 - 2656
  • [49] Preliminary use of a double-echo pulse sequence with 3D ultrashort echo time in the MRI of bones and joints
    Ma, Liheng
    Meng, Quanfei
    Chen, Yingming
    Zhang, Zhaohui
    Sun, Haixing
    Deng, Demao
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2013, 5 (05) : 1471 - 1475
  • [50] Pulmonary 3 T MRI With Ultrashort TEs: Influence of Ultrashort Echo Time Interval on Pulmonary Functional and Clinical Stage Assessments of Smokers
    Ohno, Yoshiharu
    Nishio, Mizuho
    Koyama, Hisanobu
    Yoshikawa, Takeshi
    Matsumoto, Sumiaki
    Seki, Shinichiro
    Obara, Makoto
    van Cauteren, Marc
    Takahashi, Masaya
    Sugimura, Kazuro
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (04) : 988 - 997