Simple and robust saturation-based slice selection for ultrashort echo time MRI

被引:5
|
作者
Harkins, Kevin D. [1 ]
Horch, R. Adam [1 ,2 ]
Does, Mark D. [1 ,2 ,3 ,4 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Biomed Engn, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Radiol & Radiol Sci, Nashville, TN 37235 USA
[4] Vanderbilt Univ, Elect Engn, Nashville, TN 37235 USA
关键词
ultrashort echo time; UTE; slice selective; saturation; 2D; PULSE SEQUENCES; T-2; RELAXATION; EDDY CURRENTS; RF PULSES; COMPENSATION; EXCITATION; DESIGN; KERNEL; TISSUE;
D O I
10.1002/mrm.25361
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo present a new method for localizing signal within a two-dimensional (2D) slice suitable for ultrashort echo time (UTE) imaging, called saturation-based UTE (sat-UTE). The new method digitally subtracts two acquisitions that are nonselectively excited with and without selective saturation of the slice of interest. MethodsSat-UTE was compared with half-pulse and double-half pulse excited UTE within phantoms, as well as 3D-UTE within ex vivo femur and in vivo tibia. Numerical simulations were also used to quantify the effects of slice profile broadening and signal component amplitudes for quantitative UTE. ResultsSat-UTE is robust to suppress out-of-slice signal, and produces short T-2 signal decay curves comparable to 3D-UTE, but has a lower signal to noise ratio efficiency compared with other slice-selective methods. ConclusionThe proposed method is useful for fast, quantitative evaluation of short T-2 signals, and is insensitive to gradient performance. Magn Reson Med 73:2204-2211, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:2204 / 2211
页数:8
相关论文
共 50 条
  • [21] The accuracy of ultrashort echo time MRI sequences for medical additive manufacturing
    van Eijnatten, Maureen
    Rijkhorst, Erik-Jan
    Hofman, Mark
    Forouzanfar, Tymour
    Wolff, Jan
    DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (05)
  • [22] Nonlinear time delay saturation-based controller for suppression of nonlinear beam vibrations
    Saeed, N. A.
    El-Ganini, W. A.
    Eissa, M.
    APPLIED MATHEMATICAL MODELLING, 2013, 37 (20-21) : 8846 - 8864
  • [23] ULTRASHORT ECHO TIME MRI CAN EVALUATE TREATMENT EFFECT OF LUMACAFTOR/IVACAFTOR
    Wainwright, C.
    Nagle, S.
    Brody, A.
    Woods, J.
    Johnson, K.
    Wang, L.
    Marigowda, G.
    Waltz, D.
    Goldin, J.
    Ratjen, F.
    Hug, C.
    RESPIROLOGY, 2018, 23 : 141 - 141
  • [24] Conical ultrashort echo time (UTE) MRI in the evaluation of pediatric acute appendicitis
    Roh, Albert T.
    Xiao, Zhibo
    Cheng, Joseph Y.
    Vasanawala, Shreyas S.
    Loening, Andreas M.
    ABDOMINAL RADIOLOGY, 2019, 44 (01) : 22 - 30
  • [25] Conical ultrashort echo time (UTE) MRI in the evaluation of pediatric acute appendicitis
    Albert T. Roh
    Zhibo Xiao
    Joseph Y. Cheng
    Shreyas S. Vasanawala
    Andreas M. Loening
    Abdominal Radiology, 2019, 44 : 22 - 30
  • [26] Clinical application of ultrashort echo-time MRI for lung pathologies in children
    Geiger, J.
    Zeimpekis, K. G.
    Jung, A.
    Moeller, A.
    Kellenberger, C. J.
    CLINICAL RADIOLOGY, 2021, 76 (09) : 708.e9 - 708.e17
  • [27] Comparison of Ultrashort Echo Time Sequences for MRI of an Ancient Mummified Human Hand
    Oezen, Ali Caglar
    Ludwig, Ute
    Oehrstroem, Lena Maria
    Ruehli, Frank Jakobus
    Bock, Michael
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (02) : 701 - 708
  • [28] Applicator visualization using ultrashort echo time MRI for HDR endorectal brachytherapy
    Kerkhof, E.
    van den Ende, R.
    Ercan, E.
    Keesman, R.
    Marijnen, C.
    van der Heide, U.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S89 - S90
  • [29] 3D ULTRASHORT ECHO TIME MRI OF CYSTIC FIBROSIS AIR TRAPPING
    Nagle, S. K.
    Johnson, K. M.
    Bell, L. C.
    Christopher, F. J.
    Rock, M. J.
    Sanders, D. B.
    Hollatz, T. J.
    Meyer, K. C.
    Fain, S. B.
    PEDIATRIC PULMONOLOGY, 2014, 49 : 352 - 352
  • [30] Comparison of optimized soft-tissue suppression schemes for ultrashort echo time MRI
    Li, Cheng
    Magland, Jeremy F.
    Rad, Hamidreza Saligheh
    Song, Hee Kwon
    Wehrli, Felix W.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 680 - 689