Simple and robust saturation-based slice selection for ultrashort echo time MRI

被引:5
|
作者
Harkins, Kevin D. [1 ]
Horch, R. Adam [1 ,2 ]
Does, Mark D. [1 ,2 ,3 ,4 ]
机构
[1] Vanderbilt Univ, Inst Imaging Sci, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Biomed Engn, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Radiol & Radiol Sci, Nashville, TN 37235 USA
[4] Vanderbilt Univ, Elect Engn, Nashville, TN 37235 USA
关键词
ultrashort echo time; UTE; slice selective; saturation; 2D; PULSE SEQUENCES; T-2; RELAXATION; EDDY CURRENTS; RF PULSES; COMPENSATION; EXCITATION; DESIGN; KERNEL; TISSUE;
D O I
10.1002/mrm.25361
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo present a new method for localizing signal within a two-dimensional (2D) slice suitable for ultrashort echo time (UTE) imaging, called saturation-based UTE (sat-UTE). The new method digitally subtracts two acquisitions that are nonselectively excited with and without selective saturation of the slice of interest. MethodsSat-UTE was compared with half-pulse and double-half pulse excited UTE within phantoms, as well as 3D-UTE within ex vivo femur and in vivo tibia. Numerical simulations were also used to quantify the effects of slice profile broadening and signal component amplitudes for quantitative UTE. ResultsSat-UTE is robust to suppress out-of-slice signal, and produces short T-2 signal decay curves comparable to 3D-UTE, but has a lower signal to noise ratio efficiency compared with other slice-selective methods. ConclusionThe proposed method is useful for fast, quantitative evaluation of short T-2 signals, and is insensitive to gradient performance. Magn Reson Med 73:2204-2211, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:2204 / 2211
页数:8
相关论文
共 50 条
  • [1] Ultrashort echo time MRI biomarkers of asthma
    Sheikh, Khadija
    Guo, Fumin
    Capaldi, Dante P. I.
    Ouriadov, Alexei
    Eddy, Rachel L.
    Svenningsen, Sarah
    Parraga, Grace
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 45 (04) : 1204 - 1215
  • [2] Ultrashort echo time and zero echo time MRI at 7T
    Peder E. Z. Larson
    Misung Han
    Roland Krug
    Angela Jakary
    Sarah J. Nelson
    Daniel B. Vigneron
    Roland G. Henry
    Graeme McKinnon
    Douglas A. C. Kelley
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2016, 29 : 359 - 370
  • [3] Ultrashort echo time and zero echo time MRI at 7T
    Larson, Peder E. Z.
    Han, Misung
    Krug, Roland
    Jakary, Angela
    Nelson, Sarah J.
    Vigneron, Daniel B.
    Henry, Roland G.
    McKinnon, Graeme
    Kelley, Douglas A. C.
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2016, 29 (03) : 359 - 370
  • [4] A Simple Saturation-based Image Fusion Technique for Static Scenes
    Peljor, Geley
    Kondo, Toshiaki
    [J]. 2015 7th International Conference on Information Technology and Electrical Engineering (ICITEE), 2015, : 241 - 246
  • [5] Ultrashort echo time (UTE) MRI of the spine in thalassaemia
    Hall-Craggs, MA
    Porter, J
    Gatehouse, PD
    Bydder, GM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (914): : 104 - 110
  • [6] Performance of Clause Selection Heuristics for Saturation-Based Theorem Proving
    Schulz, Stephan
    Moehrmann, Martin
    [J]. AUTOMATED REASONING (IJCAR 2016), 2016, 9706 : 330 - 345
  • [7] CONVENTIONAL AND ULTRASHORT ECHO TIME MRI COMPARED WITH CT
    Nagle, S.
    Francois, C.
    Poranski, M.
    Bell, L.
    Johnson, K.
    Fain, S.
    [J]. PEDIATRIC PULMONOLOGY, 2016, 51 : 351 - 352
  • [8] MRI-Based Attenuation Correction for PET/MRI Using Ultrashort Echo Time Sequences
    Keereman, Vincent
    Fierens, Yves
    Broux, Tom
    De Deene, Yves
    Lonneux, Max
    Vandenberghe, Stefaan
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (05) : 812 - 818
  • [9] Robust saturation-based control of bilateral teleoperation without velocity measurements
    Zhai, Di-Hua
    Xia, Yuanqing
    [J]. INTERNATIONAL JOURNAL OF ROBUST AND NONLINEAR CONTROL, 2015, 25 (15) : 2582 - 2607
  • [10] Expanding the Clinical Application of Lung MRI: With or without Ultrashort Echo Time or Zero Echo Time?
    Dournes, Gael
    Benlala, Ilyes
    Laurent, Francois
    [J]. RADIOLOGY, 2021, 301 (02) : E412 - E412