Application of Premature Chromosome Condensation and Dicentric Analysis in Retrospective Biological Dosimetry of Radiation Accident

被引:0
|
作者
Panek, A. [1 ]
Miszczyk, J. [1 ]
Paluszkiewicz, C. [1 ]
Pyszka, E. [1 ]
Milcewicz-Mika, I [1 ]
Smolinski, S. [2 ,3 ]
Kwiatek, W. [1 ]
Kopec, R. [1 ]
机构
[1] Polish Acad Sci, Inst Nucl Phys, PL-31342 Krakow, Poland
[2] Lower Silesian Oncol Ctr, PL-53413 Wroclaw, Poland
[3] Univ Hosp, PL-50556 Wroclaw, Poland
关键词
DOSE ASSESSMENT; EXPOSURES; ASSAY; INTERCOMPARISONS;
D O I
10.12693/APhysPolA.137.24
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Cytogenetic dosimetry based on dicentric analysis and premature chromosome condensation plays an important role in the triage and medical management of affected people in radiological accidents. In our studies, blood samples from persons that were suspected of accidental exposure to ionizing radiation during interventional radiology procedure (plastic surgery of the renal arteries) were investigated for the purpose of the retrospective biological dosimetry of absorbed dose. In this case, the obligatory reported dose value, kerma area product, was high: 106.04 Gy cm(2). The peak skin dose was reported by X-ray machine system as 17 Gy. Peak skin dose for an iso-centric interventional fluoroscope is measured at defined reference point, located 15 cm from the isocenter toward the X-ray tube. Due to the lack of possibility to connect kerma area product with an effect (kerma area product could be connected with the maximum local dose in the X-ray field) the patient's blood and 2 most-at-risk people (medical doctors) were investigated. In addition, 5 dosimeters for the whole body (Hp(10)) and 1 ring dosimeter measuring the skin exposure (Hp(0.07)) of medical workers participating in the radiological procedure were investigated. The measurements of individual doses by the thermoluminescent dosimeters were carried out by the Laboratory of Individual and Environmental Dosimetry (Polish acronym LADIS). To estimate the potentially absorbed dose lymphocytes from blood were analyzed for the presence of chromosomal aberrations (dicentrics and rings), which are the "gold standard" assay for biodosimetry. Additionally, the absorbed dose was monitored by the analysis of excess fragments with premature chromosome condensation technique, which is recommended for high doses and partial body exposure. Finally, estimated doses for obtained blood samples were compared to the dose-response curves for dicentrics and premature chromosome condensation excess fragments, detected in our laboratory after induction in human lymphocytes by in vitro X-ray irradiation.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [41] Inducing chromosome pairing through premature condensation: analysis of wheat interspecific hybrids
    Knight, Emilie
    Greer, Emma
    Draeger, Trade
    Thole, Vera
    Reader, Steve
    Shaw, Peter
    Moore, Graham
    FUNCTIONAL & INTEGRATIVE GENOMICS, 2010, 10 (04) : 603 - 608
  • [42] Inducing chromosome pairing through premature condensation: analysis of wheat interspecific hybrids
    Emilie Knight
    Emma Greer
    Tracie Draeger
    Vera Thole
    Steve Reader
    Peter Shaw
    Graham Moore
    Functional & Integrative Genomics, 2010, 10 : 603 - 608
  • [43] CYTOGENETIC ANALYSIS USING PREMATURE CHROMOSOME CONDENSATION OF TUMORS IN THE HEAD AND NECK REGION
    WANG, ZW
    CHEONG, N
    SOHN, HY
    HITTELMAN, WN
    CANCER GENETICS AND CYTOGENETICS, 1989, 41 (02) : 249 - 249
  • [44] Application of the MAX/EGS4 exposure model to the dosimetry of the Yanango radiation accident
    Kramer, R
    Santos, AM
    Brayner, CAO
    Khoury, HJ
    Vieira, JW
    Lima, FRA
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16): : 3681 - 3695
  • [45] DIRECT ANALYSIS OF RADIATION-INDUCED CHROMOSOME FRAGMENTS AND RINGS IN UNSTIMULATED HUMAN PERIPHERAL-BLOOD LYMPHOCYTES BY MEANS OF THE PREMATURE CHROMOSOME CONDENSATION TECHNIQUE
    PANTELIAS, GE
    MAILLIE, HD
    MUTATION RESEARCH, 1985, 149 (01): : 67 - 72
  • [46] Statistical issues in biological radiation dosimetry for risk assessment using stable chromosome aberrations
    Cologne, JB
    Pawel, DJ
    Preston, DL
    HEALTH PHYSICS, 1998, 75 (05): : 518 - 529
  • [47] APPLICATION OF THE PREMATURE CHROMOSOME CONDENSATION ASSAY IN SIMULATED PARTIAL-BODY RADIATION EXPOSURES - EVALUATION OF THE USE OF AN AUTOMATED METAPHASE-FINDER
    BLAKELY, WF
    PRASANNA, PGS
    KOLANKO, CJ
    PYLE, MD
    MOSBROOK, DM
    LOATS, AS
    RIPPEON, TL
    LOATS, H
    STEM CELLS, 1995, 13 : 223 - 230
  • [48] Present status and prospects for biological dosimetry using chromosome aberration analysis
    Jin, CZ
    Liu, XL
    Zhang, ZY
    Luo, YS
    RADIATION PROTECTION DOSIMETRY, 1998, 77 (1-2) : 29 - 32
  • [49] Use of FISH translocations analyses for retrospective biological dosimetry: How stable are stable chromosome aberrations?
    Darroudi, F
    RADIATION PROTECTION DOSIMETRY, 2000, 88 (01) : 101 - 109
  • [50] PREMATURE CHROMOSOME CONDENSATION IN BONE-MARROW OF CHINESE HAMSTERS AFTER APPLICATION OF BLEOMYCIN INVIVO
    KURTEN, S
    OBE, G
    MUTATION RESEARCH, 1975, 27 (02): : 285 - 294