Application of Premature Chromosome Condensation and Dicentric Analysis in Retrospective Biological Dosimetry of Radiation Accident

被引:0
|
作者
Panek, A. [1 ]
Miszczyk, J. [1 ]
Paluszkiewicz, C. [1 ]
Pyszka, E. [1 ]
Milcewicz-Mika, I [1 ]
Smolinski, S. [2 ,3 ]
Kwiatek, W. [1 ]
Kopec, R. [1 ]
机构
[1] Polish Acad Sci, Inst Nucl Phys, PL-31342 Krakow, Poland
[2] Lower Silesian Oncol Ctr, PL-53413 Wroclaw, Poland
[3] Univ Hosp, PL-50556 Wroclaw, Poland
关键词
DOSE ASSESSMENT; EXPOSURES; ASSAY; INTERCOMPARISONS;
D O I
10.12693/APhysPolA.137.24
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Cytogenetic dosimetry based on dicentric analysis and premature chromosome condensation plays an important role in the triage and medical management of affected people in radiological accidents. In our studies, blood samples from persons that were suspected of accidental exposure to ionizing radiation during interventional radiology procedure (plastic surgery of the renal arteries) were investigated for the purpose of the retrospective biological dosimetry of absorbed dose. In this case, the obligatory reported dose value, kerma area product, was high: 106.04 Gy cm(2). The peak skin dose was reported by X-ray machine system as 17 Gy. Peak skin dose for an iso-centric interventional fluoroscope is measured at defined reference point, located 15 cm from the isocenter toward the X-ray tube. Due to the lack of possibility to connect kerma area product with an effect (kerma area product could be connected with the maximum local dose in the X-ray field) the patient's blood and 2 most-at-risk people (medical doctors) were investigated. In addition, 5 dosimeters for the whole body (Hp(10)) and 1 ring dosimeter measuring the skin exposure (Hp(0.07)) of medical workers participating in the radiological procedure were investigated. The measurements of individual doses by the thermoluminescent dosimeters were carried out by the Laboratory of Individual and Environmental Dosimetry (Polish acronym LADIS). To estimate the potentially absorbed dose lymphocytes from blood were analyzed for the presence of chromosomal aberrations (dicentrics and rings), which are the "gold standard" assay for biodosimetry. Additionally, the absorbed dose was monitored by the analysis of excess fragments with premature chromosome condensation technique, which is recommended for high doses and partial body exposure. Finally, estimated doses for obtained blood samples were compared to the dose-response curves for dicentrics and premature chromosome condensation excess fragments, detected in our laboratory after induction in human lymphocytes by in vitro X-ray irradiation.
引用
收藏
页码:24 / 28
页数:5
相关论文
共 50 条
  • [21] PREMATURE CHROMOSOME CONDENSATION AND CELL-CYCLE ANALYSIS
    RAO, PN
    WILSON, B
    PUCK, TT
    JOURNAL OF CELLULAR PHYSIOLOGY, 1977, 91 (01) : 131 - 141
  • [22] PREMATURE CHROMOSOME CONDENSATION FOR CELL-CYCLE ANALYSIS
    RAO, PN
    WILSON, BA
    JOURNAL OF CELL BIOLOGY, 1976, 70 (02): : A279 - A279
  • [23] Retrospective cytogenetic analysis of unstable and stable chromosome aberrations in the victims of radiation accident in Bulgaria
    Balajee, Adayabalam S.
    Hadjidekova, Valeria
    MUTATION RESEARCH-GENETIC TOXICOLOGY AND ENVIRONMENTAL MUTAGENESIS, 2021, 861
  • [24] THE MEASUREMENT OF RADIATION-DAMAGE IN LYMPHOCYTES USING PREMATURE CHROMOSOME CONDENSATION
    PANTELIAS, GE
    MAILLIE, HD
    HEALTH PHYSICS, 1983, 45 (01): : 195 - 195
  • [26] RENEB interlaboratory comparison for biological dosimetry based on dicentric chromosome analysis and cobalt-60 exposures higher than 2.5 Gy
    Bucher, Martin
    Endesfelder, David
    Pojtinger, Stefan
    Baeyens, Ans
    Barquinero, Joan-Francesc
    Beinke, Christina
    Bobyk, Laure
    Gregoire, Eric
    Hristova, Rositsa
    Martinez, Juan S.
    Meher, Prabodha Kumar
    Milanova, Marcela
    Gil, Octavia Monteiro
    Montoro, Alegria
    Moquet, Jayne
    Moreno Domene, Mercedes
    Prieto, Maria Jesus
    Pujol-Canadell, Monica
    Sun, Mingzhu
    Terzoudi, Georgia I.
    Tichy, Ales
    Triantopoulou, Sotiria
    Valente, Marco
    Vral, Anne
    Wojcik, Andrzej
    Oestreicher, Ursula
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [27] Construction of dose response curve for 6 MV LINAC X-rays using Premature Chromosome Condensation assay for radiation dosimetry
    Meenakshi, C.
    Venkatachalam, P.
    Chandrasekaran, S.
    Venkatraman, B.
    APPLIED RADIATION AND ISOTOPES, 2021, 173
  • [28] PREMATURE CHROMOSOME CONDENSATION IN PERSONS EXPOSED TO OCCUPATIONAL RADIATION AND IN TUMOR PATIENTS RECEIVING THERAPEUTIC RADIATION
    ANGER, H
    WITKOWSKI, R
    RADIOBIOLOGIA-RADIOTHERAPIA, 1977, 18 (05) : 633 - 638
  • [29] Conventional radiation biological dosimetry using frequencies of unstable chromosome aberrations
    Ramalho, AT
    Costa, MLP
    Oliveira, MS
    MUTATION RESEARCH-FUNDAMENTAL AND MOLECULAR MECHANISMS OF MUTAGENESIS, 1998, 404 (1-2) : 97 - 100
  • [30] Retrospective assessment of radiation exposure using biological dosimetry: Chromosome painting, electron paramagnetic resonance and the glycophorin A mutation assay
    Kleinerman, RA
    Romanyukha, AA
    Schauer, DA
    Tucker, JD
    RADIATION RESEARCH, 2006, 166 (01) : 287 - 302