A study on beams passing through hip prosthesis for pelvic radiation treatment

被引:64
|
作者
Ding, GX [1 ]
Yu, CW [1 ]
机构
[1] British Columbia Canc Agcy, Fraser Valley Canc Ctr, Clin Phys Dept, Dept Med Phys, Surrey, BC V3V 1Z2, Canada
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 51卷 / 04期
关键词
pelvic radiotherapy; hip prostheses; dose at interface; treatment planning; inhomogeneity corrections;
D O I
10.1016/S0360-3016(01)02592-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To study the dose distributions at the interface due to the presence of a metal implant; to show the dose distributions in combined fields in the presence of hip prostheses; and to demonstrate the capabilities and limitations of a conventional system. Methods and Materials: Perturbations in the dose distribution caused by a hip prosthesis can result in unacceptable dose inhomogeneities within the target volume and in regions where tissues interface with implant. The Monte Carlo technique and a conventional treatment planning system are used to calculate the dose distributions. Results: Dose increases of 15% in tissue are seen at the interface between metal implant and tissue. Dose reductions of 5-25% or 10-45% are observed in the shadow of the hip prosthesis made of 0.5-3-cm-thick titanium or steel alloy respectively. We compared predicted dose distribution between the Monte Carlo simulation and a commercial treatment planning system (CADPLAN). We found that CADPLAN underestimated the attenuation of hip prostheses. This has led to overestimation of the target dose by 14% for a typical four-field box technique. Conclusions: An acceptable dose distribution can be achieved with a proper lateral beam weighting and compensation using an eight-field technique. The beam compensation may be applied to achieve an adequate target dose. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:1167 / 1175
页数:9
相关论文
共 50 条
  • [41] TRIBOLOGICAL STUDY OF TOTAL HIP-PROSTHESIS
    TEINTURIER, P
    TERVER, S
    LI, J
    TAUSSAT, A
    CAILLOT, A
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 1990, 76 (06): : 383 - 390
  • [42] TOTAL HIP PROSTHESIS IN TREATMENT OF PSEUDOARTHROSIS OF NECK OF FEMUR
    AGRIFOGL.E
    MINERVA ORTOPEDICA, 1973, 24 (12): : 491 - 499
  • [43] THE RADIATION FROM A CHARGED PARTICLE PASSING THROUGH A PLATE
    GARIBIAN, GM
    CHALIKIAN, GA
    SOVIET PHYSICS JETP-USSR, 1959, 8 (05): : 894 - 895
  • [44] Wake of a beam passing through a diffraction radiation target
    Xiang, Dao
    Huang, Wen-Hui
    Lin, Yu-Zheng
    Park, Sung-Ju
    Ko, In Soo
    PHYSICAL REVIEW SPECIAL TOPICS-ACCELERATORS AND BEAMS, 2008, 11 (02):
  • [45] RADIATION EMITTED BY A CHARGED PARTICLE PASSING THROUGH A PLATE
    PAFOMOV, VE
    SOVIET PHYSICS JETP-USSR, 1961, 12 (01): : 97 - 99
  • [46] Biological Prosthesis for Total Hip Arthroplasty in Treatment of Adult Developmental Dysplasia of the Hip
    Xie, Zong-gang
    Dong, Qi-rong
    Xie, Ye
    ORTHOPAEDIC SURGERY, 2014, 6 (03) : 255 - 256
  • [47] ON TRANSITION RADIATION OF CURRENTS PASSING THROUGH BOUNDARY OF A PLASMA
    TSYTOVICH, VN
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1962, 6 (07): : 554 - &
  • [48] Dosimetric effect of a hip prosthesis when delivering intensity modulated radiation therapy (IMRT): a phantom study
    Bayouth, J
    Followill, D
    Nelson, A
    Ibbott, G
    Morrill, S
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S105 - S105
  • [49] Theoretical study on the spectral shifts of partially coherent array beams passing through ABCD optical systems
    Pan, Leilei
    Zhang, Bin
    JOURNAL OF MODERN OPTICS, 2009, 56 (21) : 2340 - 2347
  • [50] A new effect observed on passing electron beams through narrow slits
    McFarlane, W