A study on beams passing through hip prosthesis for pelvic radiation treatment

被引:64
|
作者
Ding, GX [1 ]
Yu, CW [1 ]
机构
[1] British Columbia Canc Agcy, Fraser Valley Canc Ctr, Clin Phys Dept, Dept Med Phys, Surrey, BC V3V 1Z2, Canada
关键词
pelvic radiotherapy; hip prostheses; dose at interface; treatment planning; inhomogeneity corrections;
D O I
10.1016/S0360-3016(01)02592-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To study the dose distributions at the interface due to the presence of a metal implant; to show the dose distributions in combined fields in the presence of hip prostheses; and to demonstrate the capabilities and limitations of a conventional system. Methods and Materials: Perturbations in the dose distribution caused by a hip prosthesis can result in unacceptable dose inhomogeneities within the target volume and in regions where tissues interface with implant. The Monte Carlo technique and a conventional treatment planning system are used to calculate the dose distributions. Results: Dose increases of 15% in tissue are seen at the interface between metal implant and tissue. Dose reductions of 5-25% or 10-45% are observed in the shadow of the hip prosthesis made of 0.5-3-cm-thick titanium or steel alloy respectively. We compared predicted dose distribution between the Monte Carlo simulation and a commercial treatment planning system (CADPLAN). We found that CADPLAN underestimated the attenuation of hip prostheses. This has led to overestimation of the target dose by 14% for a typical four-field box technique. Conclusions: An acceptable dose distribution can be achieved with a proper lateral beam weighting and compensation using an eight-field technique. The beam compensation may be applied to achieve an adequate target dose. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:1167 / 1175
页数:9
相关论文
共 50 条
  • [31] Extracting Mode Shapes for Beams Through a Passing Auxiliary Mass
    Zhang, Yao
    Zhao, Hai-Sheng
    Lie, Seng-Tjhen
    JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2019, 141 (05):
  • [33] Furlong hydroxyapatite coated hip prosthesis versus the charnley cemented hip prosthesis - A prospective randomised study
    Bradley, JG
    Andrews, CM
    Lee, K
    Scott, CA
    Shaw, D
    BIOCERAMICS, 2000, 192-1 : 1013 - 1020
  • [34] Pelvic silicone prosthesis for prevention of radiation enteritis: US and CT features
    B. D. Nguyen
    U. M. Hamper
    Abdominal Imaging, 1997, 22 : 175 - 177
  • [35] Pelvic silicone prosthesis for prevention of radiation enteritis: US and CT features
    Nguyen, BD
    Hamper, UM
    ABDOMINAL IMAGING, 1997, 22 (02): : 175 - 177
  • [36] Impact of Pelvic Radiation Therapy on Inflatable Penile Prosthesis Reoperation Rates
    Golan, Ron
    Patel, Neal A.
    Sun, Tianyi
    Barbieri, Christopher E.
    Sedrakyan, Art
    Kashanian, James A.
    JOURNAL OF SEXUAL MEDICINE, 2018, 15 (11): : 1653 - 1658
  • [37] Triple Pelvic Osteotomy in the Treatment of Hip Dysplasia
    Vukasinovic, Zoran
    Spasovski, Dusko
    Zivkovic, Zorica
    Slavkovic, Nemanja
    Cerovic, Sofija
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2009, 137 (5-6) : 239 - 248
  • [38] PELVIC OSTEOTOMY IN TREATMENT OF CANINE HIP DYSPLASIA
    HOHN, RB
    JANES, JM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1969, (62) : 70 - &
  • [39] Chiari Pelvic Osteotomy in Treatment of Hip Dysplasia
    Slavkovic, Nemanja
    Vukasinovic, Zoran
    Apostolovic, Milan
    Vukomanovic, Boris
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2013, 141 (9-10) : 710 - 714
  • [40] Mechanical study of cementless hip prosthesis stability
    Hu, X.S.
    Labesse-Jied, F.
    Aït Si Selmi, T.
    Computer Methods in Biomechanics and Biomedical Engineering, 2007, 10 (SUPPL. 1) : 137 - 138