ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY

被引:14
|
作者
Silva, E. H. [1 ,2 ,3 ,4 ]
Knezevic, Z. [5 ]
Struelens, L. [1 ]
Covens, P. [2 ,3 ,6 ]
Ueno, S. [7 ]
Vanhavere, F. [1 ]
Buls, N. [2 ,3 ,8 ]
机构
[1] Belgian Nucl Res Ctr SCK CEN, Boeretang 200, B-2400 Mol, Belgium
[2] VUB, LABO, Laarbeeklaan 103, B-1090 Brussels, Belgium
[3] BEFY, Laarbeeklaan 103, B-1090 Brussels, Belgium
[4] Minist Educ Brazil, CAPES Fdn, BR-70040020 Brasilia, DF, Brazil
[5] Rudjer Boskovic Inst, Bijenicka 54, Zagreb 10000, Croatia
[6] Dept Radiat Protect VUB, Laarbeeklaan 103, B-1090 Brussels, Belgium
[7] Chiyoda Technol Corp, Oarai Res Ctr, 3681 Naritacho, Oarai, Ibaraki 3111313, Japan
[8] UZ Brussel, Dept Radiol, Laarbeeklaan 101, B-1090 Brussels, Belgium
关键词
CONVERSION COEFFICIENTS; DOSE-EQUIVALENT; AIR KERMA; RADIATION; PHANTOM; PHOTON; H-P(3);
D O I
10.1093/rpd/ncw104
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Recent studies demonstrated that lens opacities can occur at lower radiation doses than previously accepted. In view of these studies, the International Commission of Radiological Protection recommended in 2011 to reduce the eye lens dose limit from 150 mSv/y to 20 mSv/y. This implies in the need of monitoring doses received by the eye lenses. In this study, small rod radio-photoluminescent glass dosemeters (GD-300 series; AGC, Japan) were characterized in terms of their energy (ISO 4037 X-rays narrow spectrum series, S-Cs and S-Co) and angular dependence (0 up to 90 degrees, with 2 ISO energies: N-60 and S-Cs). All acquisitions were performed at SCK center dot CEN-Belgium, using the ORAMED proposed cylindrical phantom. For selected energies (N-60, N-80, N-100, N-120 and N-250), the response of dosemeters irradiated on the ISO water slab phantom, at the Ruder Boskovic Institute-Croatia, was compared to those irradiated on the cylindrical phantom. GD-300 series showed good energy dependence, relative to S-Cs, on the cylindrical phantom. From 0 up to 45 degrees, the dosemeters showed no significant angular dependence, regardless whether they were tested when placed vertically or horizontally on the cylindrical phantom. However, at higher angles, some angular dependence was observed, mainly when the dosemeters were irradiated with low-energy photons (N-60). Results showed that GD-300 series have good properties related to H-p(3), although some improvements may be necessary.
引用
收藏
页码:208 / 212
页数:5
相关论文
共 50 条
  • [41] Eye lens irradiation by CT perfusion: dosimetry and optimization
    Guersen, J.
    Cassagnes, L.
    Mechin, G.
    Etard, C.
    Rehel, J. -L.
    Jean, B.
    Chabert, E.
    Gabrillargues, J.
    Labattu, M.
    Boyer, L.
    Chabrot, P.
    [J]. RADIOPROTECTION, 2014, 49 (03) : 195 - 199
  • [42] Development of an applicator for eye lens dosimetry during radiotherapy
    Park, J. M.
    Lee, J.
    Kim, H. S.
    Ye, S-J
    Kim, J-I
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1042):
  • [43] A new cylindrical phantom for eye lens dosimetry development
    Gualdrini, G.
    Mariotti, F.
    Wach, S.
    Bilski, P.
    Denoziere, M.
    Daures, J.
    Bordy, J. -M.
    Ferrari, P.
    Monteventi, F.
    Fantuzzi, E.
    Vanhavere, F.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1231 - 1234
  • [44] On the operational quantity Hp(3) for eye lens dosimetry
    Behrens, R.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2012, 32 (04) : 455 - 464
  • [45] Eye lens dose monitoring in the UK nuclear industry using active personal dosemeters
    McWhan, A.
    Dobrzynska, W.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2018, 38 (03) : 1204 - 1216
  • [46] ENERGY DEPENDENCE OF LITHIUM FLUORIDE DOSEMETERS AND HIGH ELECTRON ENERGIES
    PINKERTON, AP
    HOLT, JG
    LAUGHLIN, JS
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1966, 11 (01): : 129 - +
  • [47] Dosimetric properties of radiophotoluminescent glass detector in low-energy photon beams
    Kadoya, Noriyuki
    Shimomura, Kouhei
    Kitou, Satoshi
    Shiota, Yasuo
    Fujita, Yukio
    Dobashi, Suguru
    Takeda, Ken
    Jingu, Keiichi
    Matsushita, Haruo
    Namito, Yoshihito
    Ban, Syuichi
    Koyama, Syuji
    Tabushi, Katsuyoshi
    [J]. MEDICAL PHYSICS, 2012, 39 (10) : 5910 - 5916
  • [48] Monte Carlo verification of the holder correction factors for the radiophotoluminescent glass dosimeter used by the IAEA in international dosimetry audits
    Sempau, J.
    Kazantsev, P.
    Izewska, J.
    Brualla, L.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 86 : 1 - 5
  • [49] DOSIMETRIC PROPERTIES OF RADIOPHOTOLUMINESCENT GLASS DOSIMETER IN HIGH-ENERGY ELECTRON BEAMS
    Son, K.
    Jung, H.
    Shin, S. H.
    Lee, H. H.
    Kim, M. S.
    Ji, Y. H.
    Kim, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S407 - S407
  • [50] Eye lens dosimetry and the study on radiation cataract in interventional cardiologists
    Matsubara, Kosuke
    Lertsuwunseri, Vorarit
    Srimahachota, Suphot
    Krisanachinda, Anchali
    Tulvatana, Wasee
    Khambhiphant, Bharkbhum
    Sudchai, Waraporn
    Rehani, Madan
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 44 : 232 - 235