Dosimetric properties of radiophotoluminescent glass detector in low-energy photon beams

被引:19
|
作者
Kadoya, Noriyuki [1 ]
Shimomura, Kouhei [2 ]
Kitou, Satoshi [3 ]
Shiota, Yasuo [4 ]
Fujita, Yukio [1 ]
Dobashi, Suguru [5 ]
Takeda, Ken [5 ]
Jingu, Keiichi [1 ]
Matsushita, Haruo [1 ]
Namito, Yoshihito [6 ]
Ban, Syuichi [6 ]
Koyama, Syuji [7 ]
Tabushi, Katsuyoshi [7 ]
机构
[1] Tohoku Univ, Dept Radiat Oncol, Sendai, Miyagi 9808574, Japan
[2] Kinki Univ Hosp, Dept Radiol Serv, Osaka 5898511, Japan
[3] Tokyo Metoropolitan Komagome Hosp, Dept Radiol, Tokyo 1138677, Japan
[4] Shizuoka Canc Ctr, Dept Radiat Therapy, Shizuoka 4110934, Japan
[5] Tohoku Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol, Sendai, Miyagi 9808575, Japan
[6] High Energy Accelerator Res Org KEK, Tsukuba, Ibaraki 3050802, Japan
[7] Nagoya Univ, Grad Sch Med, Dept Radiol & Med Lab Sci, Nagoya, Aichi 4618673, Japan
关键词
glass dosimeter; radiation therapy; energy dependence; angular dependence; SOLID-STATE DETECTORS; ROD DETECTOR; AUDIT; KNIFE;
D O I
10.1118/1.4747261
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A radiophotoluminescent glass rod dosimeter (RGD) has recently become commercially available. It is being increasingly used for dosimetry in radiotherapy to measure the absorbed dose including scattered low-energy photons on the body surface of a patient and for postal dosimetry audit. In this article, the dosimetric properties of the ROD, including energy dependence of the dose response, reproducibly, variation in data obtained by the ROD for each energy, and angular dependence in low-energy photons, are discussed. Methods: An RGD (GD-301, Asahi Techno Glass Corporation, Shizuoka, Japan) was irradiated with monochromatic low-energy photon beams generated by synchrotron radiation at Photon Factory, High Energy Accelerator Research Organization (KEK). The size of GD-301 was 1.5 mm in diameter and 8.5 mm in length and the active dose readout volume being 1 mm diameter and 0.6 mm depth located 0.7 mm from the end of the detector. The energy dependence of the dose response and reproducibility and variation were investigated for RGDs irradiated with a plastic holder and those irradiated without the plastic holder. Response of the RGD was obtained by not only conventional single field irradiation but also bilateral irradiation. Angular dependence of the RGD was measured in the range of 0 degrees-90 degrees for 13, 17, 40, and 80 keV photon beams by conventional single field irradiation. Results: The dose responses had a peak at around 40 keV. For the energy range of less than 25 keV, all dose response curves steeply decreased in comparison with the ratio of mass energy absorption coefficient of the ROD to that of air. As for the reproducibility and variation in data obtained by the RGD, the coefficient of variance increased with decrease in photon energy. Furthermore, the variation for bilateral irradiation was less than that for single field irradiation. Regarding angular dependence of the RGD, for energies of 13 and 17 keV, the response decreased with increase in the irradiation angle, and the minimum values were 93.5% and 86%, respectively. Conclusions: Our results showed the dosimetric properties of the RGD, including the energy dependence of the dose response, reproducibly, variation, and angular dependence in low-energy photons and suggest that the accuracy of the absorbed dose in low-energy photons is affected by the readout method and the distribution of radiophotoluminescence centers in the ROD. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4747261]
引用
收藏
页码:5910 / 5916
页数:7
相关论文
共 50 条
  • [1] Dosimetric properties of radiophotoluminescent glass rod detector in high-energy photon beams from a linear accelerator and Cyber-Knife
    Araki, F
    Moribe, N
    Shimonobou, T
    Yamashita, Y
    [J]. MEDICAL PHYSICS, 2004, 31 (07) : 1980 - 1986
  • [2] Investigation of the dosimetric characteristics of radiophotoluminescent glass dosimeter for high-energy photon beams
    Oonsiri, Puntiwa
    Kingkaew, Sakda
    Vannavijit, Chulee
    Suriyapee, Sivalee
    [J]. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2019, 12 (01) : 65 - 71
  • [3] DOSIMETRIC PROPERTIES OF RADIOPHOTOLUMINESCENT GLASS DOSIMETER IN HIGH-ENERGY ELECTRON BEAMS
    Son, K.
    Jung, H.
    Shin, S. H.
    Lee, H. H.
    Kim, M. S.
    Ji, Y. H.
    Kim, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S407 - S407
  • [4] Dosimetric properties of GD-300 series of radiophotoluminescent glass detector
    Zhuo, Wei-Hai
    Liu, Wei-Qi
    Huang, Gang
    Zheng, Jun-Zheng
    Liu, Hai-Kuan
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2008, 42 (12): : 1120 - 1124
  • [5] Evaluation of the dosimetric characteristics of a radiophotoluminescent glass dosimeter for high-energy photon and electron beams in the field of radiotherapy
    Son, Kihong
    Jung, Haijo
    Shin, Sang Hun
    Lee, Hyun-Ho
    Kim, Mi-Sook
    Ji, Young Hoon
    Kim, Kum Bae
    [J]. RADIATION MEASUREMENTS, 2011, 46 (10) : 1117 - 1122
  • [6] Dosimetric Characteristics of Radiophotoluminescent Glass Dosimeters for Proton Beams
    Oonsiri, Sornjarod
    Kingkaew, Sakda
    Vimolnoch, Mananchaya
    Chatchumnan, Nichakan
    Oonsiri, Puntiwa
    [J]. JOURNAL OF MEDICAL PHYSICS, 2023, 48 (03) : 238 - 242
  • [7] Relative efficiency of radiophotoluminescent glass detectors in low energy ion beams
    Majer, Marija
    Pasaricek, Luka
    Knezovic, Zeljka
    Bokulic, Tomislav
    Provatas, Georgios
    Mihalic, Iva Bozicevic
    [J]. RADIATION MEASUREMENTS, 2023, 166
  • [8] The response of a radiophotoluminescent glass dosimeter in megavoltage photon and electron beams
    Araki, Fujio
    Ohno, Takeshi
    [J]. MEDICAL PHYSICS, 2014, 41 (12)
  • [9] LOW-ENERGY EXPERIMENTS WITH CONTINUOUS ELECTRON AND PHOTON BEAMS
    PAPANICOLAS, CN
    [J]. NUCLEAR PHYSICS A, 1985, 446 (1-2) : C249 - C258
  • [10] Physical and dosimetric characteristics of radiophotoluminescent glass from two-photon excitation microscopy
    Kurobori, Toshio
    Kada, Wataru
    Yanagida, Yuka
    Koguchi, Yasuhiro
    Nanto, Hidehito
    [J]. RADIATION MEASUREMENTS, 2021, 140