ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY

被引:14
|
作者
Silva, E. H. [1 ,2 ,3 ,4 ]
Knezevic, Z. [5 ]
Struelens, L. [1 ]
Covens, P. [2 ,3 ,6 ]
Ueno, S. [7 ]
Vanhavere, F. [1 ]
Buls, N. [2 ,3 ,8 ]
机构
[1] Belgian Nucl Res Ctr SCK CEN, Boeretang 200, B-2400 Mol, Belgium
[2] VUB, LABO, Laarbeeklaan 103, B-1090 Brussels, Belgium
[3] BEFY, Laarbeeklaan 103, B-1090 Brussels, Belgium
[4] Minist Educ Brazil, CAPES Fdn, BR-70040020 Brasilia, DF, Brazil
[5] Rudjer Boskovic Inst, Bijenicka 54, Zagreb 10000, Croatia
[6] Dept Radiat Protect VUB, Laarbeeklaan 103, B-1090 Brussels, Belgium
[7] Chiyoda Technol Corp, Oarai Res Ctr, 3681 Naritacho, Oarai, Ibaraki 3111313, Japan
[8] UZ Brussel, Dept Radiol, Laarbeeklaan 101, B-1090 Brussels, Belgium
关键词
CONVERSION COEFFICIENTS; DOSE-EQUIVALENT; AIR KERMA; RADIATION; PHANTOM; PHOTON; H-P(3);
D O I
10.1093/rpd/ncw104
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Recent studies demonstrated that lens opacities can occur at lower radiation doses than previously accepted. In view of these studies, the International Commission of Radiological Protection recommended in 2011 to reduce the eye lens dose limit from 150 mSv/y to 20 mSv/y. This implies in the need of monitoring doses received by the eye lenses. In this study, small rod radio-photoluminescent glass dosemeters (GD-300 series; AGC, Japan) were characterized in terms of their energy (ISO 4037 X-rays narrow spectrum series, S-Cs and S-Co) and angular dependence (0 up to 90 degrees, with 2 ISO energies: N-60 and S-Cs). All acquisitions were performed at SCK center dot CEN-Belgium, using the ORAMED proposed cylindrical phantom. For selected energies (N-60, N-80, N-100, N-120 and N-250), the response of dosemeters irradiated on the ISO water slab phantom, at the Ruder Boskovic Institute-Croatia, was compared to those irradiated on the cylindrical phantom. GD-300 series showed good energy dependence, relative to S-Cs, on the cylindrical phantom. From 0 up to 45 degrees, the dosemeters showed no significant angular dependence, regardless whether they were tested when placed vertically or horizontally on the cylindrical phantom. However, at higher angles, some angular dependence was observed, mainly when the dosemeters were irradiated with low-energy photons (N-60). Results showed that GD-300 series have good properties related to H-p(3), although some improvements may be necessary.
引用
收藏
页码:208 / 212
页数:5
相关论文
共 50 条
  • [1] OPTIMIZATION OF A RADIOPHOTOLUMINESCENT GLASS DOSEMETER FOR OCCUPATIONAL EYE LENS DOSIMETRY IN INTERVENTIONAL RADIOLOGY/CARDIOLOGY
    Silva, Edilaine H.
    Struelens, Lara
    Covens, Peter
    Ueno, Satoshi
    Koguchi, Yasuhiro
    Vanhavere, Filip
    Buls, Nico
    [J]. RADIATION PROTECTION DOSIMETRY, 2018, 182 (02) : 177 - 183
  • [2] Comparison on characteristics of radiophotoluminescent glass dosemeters and thermoluminescent dosemeters
    Hsu, Shih-Ming
    Yeh, Shann-Horng
    Lin, Meei-Shiow
    Chen, Wei-Li
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 327 - 331
  • [3] INFLUENCE OF DIFFERENT TYPES OF PHANTOMS ON THE CALIBRATION OF DOSEMETERS FOR EYE LENS DOSIMETRY
    Yoshitomi, H.
    Kowatari, M.
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 199 - 203
  • [4] Dosimertry characteristics and performance comparisons: Environmental radiophotoluminescent glass dosemeters versus thermoluminescent dosemeters
    Lee, J. H.
    Lin, M. S.
    Hsu, S. M.
    Chen, I. J.
    Chen, W. L.
    Wang, C. F.
    [J]. RADIATION MEASUREMENTS, 2009, 44 (01) : 86 - 91
  • [5] Eye lens dosimetry with BeOSL Hp(3) dosemeters in interventional angiography and neuroradiology
    Strobel, I
    Bandalo, V
    Herz, K.
    Fehrenbacher, G.
    Grozinger, G.
    Artzner, C.
    Bronner, J.
    Kleinau, P.
    Hoedlmoser, H.
    [J]. RADIATION MEASUREMENTS, 2021, 143
  • [6] INTERCOMPARISON OF EYE LENS DOSEMETERS
    Behrens, R.
    Hupe, O.
    Busch, F.
    Denk, J.
    Engelhardt, J.
    Gunther, K.
    Hoedlmoser, H.
    Jordan, M.
    Strohmaier, J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2017, 174 (01) : 6 - 12
  • [7] The energy and angular Hp(3,a) response of commercial eye-lens dosemeters to photon and beta particle radiation
    Dubeau, J.
    Sun, J.
    Leroux, N.
    Djeffal, S.
    Mistry, R.
    [J]. RADIATION MEASUREMENTS, 2023, 167
  • [8] PRINCIPLES FOR THE DESIGN AND CALIBRATION OF RADIATION PROTECTION DOSEMETERS FOR OPERATIONAL AND PROTECTION QUANTITIES FOR EYE LENS DOSIMETRY
    Bordy, J. M.
    Gualdrini, G.
    Daures, J.
    Mariotti, F.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) : 257 - 261
  • [9] Personal Fast Neutrons Dosimetry Using Radiophotoluminescent Glass
    Salem, Y. O.
    Nachab, A.
    Roy, C.
    Nourreddine, A.
    [J]. 2013 3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN NUCLEAR INSTRUMENTATION, MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA), 2013,
  • [10] Photon energy dependence and angular response of glass display used in mobile phones for accident dosimetry
    Discher, Michael
    Greiter, Matthias
    Woda, Clemens
    [J]. RADIATION MEASUREMENTS, 2014, 71 : 471 - 474