Dosimetric Analysis of Microscopic Disease in SBRT for Lung Cancers

被引:1
|
作者
Mao, Ronghu [1 ]
Tian, Lingling [1 ]
Zhang, You [2 ]
Ren, Lei [2 ]
Gao, Renqi [2 ]
Yin, Fang-Fang [2 ]
Ge, Hong [1 ]
机构
[1] Zhengzhou Univ, Affiliated Canc Hosp, Henan Canc Hosp, Dept Radiat Oncol, 127 Dongming Rd, Zhengzhou 450008, Henan, Peoples R China
[2] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC USA
基金
中国国家自然科学基金;
关键词
microscopic disease; 4DCT; probability distribution function; lung SBRT; target motion; CLINICAL TARGET VOLUME; GAFCHROMIC EBT FILM; RADIATION-THERAPY; ORGAN MOTION; BREATH-HOLD; EXTENSION; RADIOTHERAPY; DELINEATION; DELIVERY;
D O I
10.1177/1533034617734689
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: The objective of this study is to theoretically and experimentally evaluate the dosimetry in the microscopic disease regions surrounding the tumor under stereotactic body radiation therapy of lung cancer. Methods: For simplicity, the tumor was considered moving along 1 dimension with a periodic function. The probability distribution function of the tumor position was generated according to the motion pattern and was used to estimate the delivered dose in the microscopic disease region. An experimental measurement was conducted to validate both the estimated dose with a probability function and the calculated dose from 4-dimensional computed tomography data using a dynamic thorax phantom. Four tumor motion patterns were simulated with cos(4)(x) and sin(x), each with 2 different amplitudes: 10 mm and 5 mm. A 7-field conformal plan was created for treatment delivery. Both films (EBT2) and optically stimulated luminescence detectors were inserted in and around the target of the phantom to measure the delivered doses. Dose differences were evaluated using gamma analysis with 3%/3 mm. Results: The average gamma index between measured doses using film and calculated doses using average intensity projection simulation computed tomography was 80.8% 0.9%. In contrast, between measured doses using film and calculated doses accumulated from 10 sets of 4-dimensional computed tomography data, it was 98.7% +/- 0.6%. The measured doses using optically stimulated luminescence detectors matched very well (within 5% of the measurement uncertainty) with the theoretically calculated doses using probability distribution function at the corresponding position. Respiratory movement caused inadvertent irradiation exposure, with 70% to 80% of the dose line wrapped around the 10 mm region outside the target. Conclusion: The use of static dose calculation in the treatment planning system could substantially underestimate the actual delivered dose in the microscopic disease region for a moving target. The margin for microscopic disease may be substantially reduced or even eliminated for lung stereotactic body radiation therapy.
引用
收藏
页码:1113 / 1119
页数:7
相关论文
共 50 条
  • [41] CT appearance of radiation injury of the lung and clinical symptoms after stereotactic body radiation therapy (SBRT) for lung cancers: Are patients with pulmonary emphysema also candidates for SBRT for lung cancers?
    Kimura, Tomoki
    Matsuura, Kanji
    Murakami, Yuji
    Hashimoto, Yasutoshi
    Kenjo, Masahiro
    Kaneyasu, Yuko
    Wadasaki, Koichi
    Hirokawa, Yutaka
    Ito, Katsuhide
    Okawa, Motoomi
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (02): : 483 - 491
  • [42] Dosimetric Evaluation of Centrally Located Lung Tumors: A Monte Carlo (MC) Study of Lung SBRT Planning
    Pokhrel, D.
    Badkul, R.
    Jiang, H.
    Saleh, H.
    Estes, C.
    Park, J.
    Kumar, P.
    Wang, F.
    MEDICAL PHYSICS, 2014, 41 (06) : 167 - 167
  • [43] Uncertainties in the dosimetric heterogeneity correction and its potential effect on local control in lung SBRT
    Erickson, Brett G.
    Cui, Yunfeng
    Ackerson, Bradley G.
    Kelsey, Christopher R.
    Yin, Fang-Fang
    Niedzwiecki, Donna
    Adamson, Justus
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (03)
  • [44] Dosimetric Parameters Are Associated with Local Control After SBRT for Colorectal Cancer Lung Metastases
    Laird, James
    Mokhtech, Meriem
    Johung, Kimberly
    Park, Henry
    Jethwa, Krishan
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2022, 45 (09): : S1 - S1
  • [45] Quantifying Plan Quality Metrics using Conventional and Stereotactic dosimetric indices in Lung SBRT
    Yaparpalvi, R.
    Garg, M.
    Bodner, W.
    Shen, J.
    Mynampati, D.
    Kuo, H.
    Ohri, N.
    Fox, J.
    Basavatia, A.
    Kalnicki, S.
    Tome, W.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S853 - S853
  • [46] Dosimetric effects of rotational offsets in stereotactic body radiation therapy (SBRT) for lung cancer
    Yang, Yun
    Catalano, Suzanne
    Kelsey, Chris R.
    Yoo, David S.
    Yin, Fang-Fang
    Cai, Jing
    MEDICAL DOSIMETRY, 2014, 39 (01) : 117 - 121
  • [47] Dosimetric comparison of the two dose reporting modes of Acuros XB and AAA for lung SBRT
    Mampuya, A. W.
    Nakamura, M.
    Hirose, Y.
    Ishigaki, T.
    Mizowaki, T.
    Hiraoka, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S718 - S718
  • [48] Dosimetric Evaluation of a Conformal Seven Field Co-planar Lung SBRT Technique
    Richmond, N.
    Green, J.
    Bradley, J.
    Peedell, C.
    Shakespeare, D.
    CLINICAL ONCOLOGY, 2011, 23 (03) : S50 - S50
  • [49] DOSIMETRIC EVALUATION STUDY OF 10-MV FFF USED IN SBRT FOR LUNG TUMOURS
    Soliman, Mohamed I.
    Attia, Wahib M.
    Elshahat, Khaled M.
    EAST EUROPEAN JOURNAL OF PHYSICS, 2023, (03): : 457 - 465
  • [50] Dosimetric Evaluation of Flattening Filter-free (FFF) Photon Beams for Lung SBRT
    Chen, Q.
    Cai, J.
    Wu, Q.
    Yin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S609 - S609