Dosimetric Analysis of Microscopic Disease in SBRT for Lung Cancers

被引:1
|
作者
Mao, Ronghu [1 ]
Tian, Lingling [1 ]
Zhang, You [2 ]
Ren, Lei [2 ]
Gao, Renqi [2 ]
Yin, Fang-Fang [2 ]
Ge, Hong [1 ]
机构
[1] Zhengzhou Univ, Affiliated Canc Hosp, Henan Canc Hosp, Dept Radiat Oncol, 127 Dongming Rd, Zhengzhou 450008, Henan, Peoples R China
[2] Duke Univ, Med Ctr, Dept Radiat Oncol, Durham, NC USA
基金
中国国家自然科学基金;
关键词
microscopic disease; 4DCT; probability distribution function; lung SBRT; target motion; CLINICAL TARGET VOLUME; GAFCHROMIC EBT FILM; RADIATION-THERAPY; ORGAN MOTION; BREATH-HOLD; EXTENSION; RADIOTHERAPY; DELINEATION; DELIVERY;
D O I
10.1177/1533034617734689
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective: The objective of this study is to theoretically and experimentally evaluate the dosimetry in the microscopic disease regions surrounding the tumor under stereotactic body radiation therapy of lung cancer. Methods: For simplicity, the tumor was considered moving along 1 dimension with a periodic function. The probability distribution function of the tumor position was generated according to the motion pattern and was used to estimate the delivered dose in the microscopic disease region. An experimental measurement was conducted to validate both the estimated dose with a probability function and the calculated dose from 4-dimensional computed tomography data using a dynamic thorax phantom. Four tumor motion patterns were simulated with cos(4)(x) and sin(x), each with 2 different amplitudes: 10 mm and 5 mm. A 7-field conformal plan was created for treatment delivery. Both films (EBT2) and optically stimulated luminescence detectors were inserted in and around the target of the phantom to measure the delivered doses. Dose differences were evaluated using gamma analysis with 3%/3 mm. Results: The average gamma index between measured doses using film and calculated doses using average intensity projection simulation computed tomography was 80.8% 0.9%. In contrast, between measured doses using film and calculated doses accumulated from 10 sets of 4-dimensional computed tomography data, it was 98.7% +/- 0.6%. The measured doses using optically stimulated luminescence detectors matched very well (within 5% of the measurement uncertainty) with the theoretically calculated doses using probability distribution function at the corresponding position. Respiratory movement caused inadvertent irradiation exposure, with 70% to 80% of the dose line wrapped around the 10 mm region outside the target. Conclusion: The use of static dose calculation in the treatment planning system could substantially underestimate the actual delivered dose in the microscopic disease region for a moving target. The margin for microscopic disease may be substantially reduced or even eliminated for lung stereotactic body radiation therapy.
引用
收藏
页码:1113 / 1119
页数:7
相关论文
共 50 条
  • [31] Evaluating dosimetric indices in lung SBRT for establishing treatment plan quality guidelines
    Yaparpalvi, R.
    Garg, M.
    Shen, J.
    Bodner, W.
    Mynamapati, D.
    Kuo, H. C.
    Scripes, P. G.
    Basavatia, A.
    Ohri, N.
    Tome, W. A.
    Kalnicki, S.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S402 - S402
  • [32] Lung SBRT Dosimetric Comparison of 3D Conformal and RapidArc Planning
    Jiang, R.
    Zhan, L.
    Osei, E.
    MEDICAL PHYSICS, 2015, 42 (06) : 3459 - 3459
  • [33] Dosimetric Comparison of Arms Up Versus Arms Down Positions for Lung SBRT
    Carpenter, T.
    Santoro, J. P.
    Lischalk, J. W.
    Ebling, D. W.
    Repka, M. C.
    Witten, M.
    Haas, J. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 112 (02): : E12 - E12
  • [34] Influence of ITV-PTV margins on interfraction dosimetric variations in lung SBRT
    Garcia Perez, A.
    Gonzalez-Pose, A.
    Lopez-Medina, A.
    Teijeiro-Garcia, A. G.
    Vazquez-Rodriguez, J.
    Andrade-Alvarez, B.
    Medal-Francesch, D.
    Salvador-Gomez, F. J.
    Salgado-Fernandez, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S911 - S912
  • [35] Quantification of Dosimetric Error in Real-Time MLC Tracking for Lung SBRT
    Modiri, A.
    Sawant, A.
    MEDICAL PHYSICS, 2017, 44 (06) : 3038 - 3038
  • [36] Dosimetric impact of Acuros XB Dose Calculation Algorithm on lung SBRT treatments
    Munoz Montplet, C.
    Agramunt Chaler, S.
    Jurado Bruggeman, D.
    Romera Martinez, I.
    Oliva, E.
    Fuentes, R.
    Rosello, A.
    Aunon, C.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S772 - S773
  • [37] Using ROC Analysis to Determine the Optimal Lung Dosimetric Parameter as the Risk Factor of Survival for SBRT in NSCLC Patients
    Yao, H.
    Wang, W.
    Kong, F.
    Jin, J.
    Vile, D.
    Liu, Y.
    Shiue, K.
    Cerra-Franco, A.
    Bartlett, G.
    Lautenschlaeger, T.
    MEDICAL PHYSICS, 2017, 44 (06) : 2999 - 2999
  • [38] Evaluation of the Dosimetric Characteristics of Salvage Lung SBRT with Image Deformable Registration Technique
    Li, Kaile
    Jung, Eward
    JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (09) : S565 - S565
  • [39] A dosimetric analysis of a spine SBRT specific treatment planning system
    Saenz, Daniel L.
    Crownover, Richard
    Stathakis, Sotirios
    Papanikolaou, Niko
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 154 - 159
  • [40] Dosimetric Impact of Dose Calculation Algorithms on Lung SBRT Plan for COPD Patients
    Jang, S.
    Lee, S.
    Zhang, X.
    Mak, K.
    Hirsch, A.
    Truong, M.
    MEDICAL PHYSICS, 2021, 48 (06)