Lung isolation during port-access cardiac surgery: Double-lumen endotracheal tube versus single-lumen endotracheal tube with a bronchial blocker

被引:21
|
作者
Grocott, HP
Darrow, TR
Whiteheart, DL
Glower, DD
Smith, MS
机构
[1] Duke Univ, Med Ctr, Dept Anesthesiol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Surg, Durham, NC 27710 USA
关键词
one-lung ventilation; double-lumen endotracheal; tube; bronchial blocker; port-access cardiac surgery;
D O I
10.1053/j.jvca.2003.09.012
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The purpose of this study was to compare the use of a double-lumen endotracheal tube to a single-lumen tube combined with a bronchial blocker for lung isolation during Port-Access cardiac surgery. Design: Prospective, randomized, controlled trial. Setting: Tertiary care university hospital. Participants: Thirty-two patients undergoing Port-Access cardiac surgery via a right minithoracotomy. Interventions: Patients were randomized to intubation with either a left-sided double-lumen tube (double-lumen group) or a single-lumen tube with concomitant use of a bronchial blocker (blocker group). Comparisons between groups included (1) intubation time, (2) number of laryngoscopy attempts, (3) time required for tube exchange at the end of the operation, and (4) surgical satisfaction with the lung deflation (1-5 scale: 5 = excellent). Measurements and Main Results: The initial intubation time was similar between groups (118 82 seconds, double-lumen v 144 +/- 32 seconds, blocker; P = 0.2781). An additional 105 +/- 37 seconds was needed to exchange the double-lumen tube at the end of the operation. The double-lumen group also required more laryngoscopy attempts compared with the blocker group (2.3 +/- 0.6, double-lumen v 1.1 +/- 0.4, blocker; p = 0.0001). The lung deflation was better in the double-lumen group (5 [4-5], double-lumen v 4 [3-5], blocker, p = 0.0414). Conclusions: Compared with a single-lumen tube/bronchial blocker combination the double-lumen endotracheal tube required more laryngoscopy attempts and additional time to replace the tube at the end of the case but resulted in slightly better overall lung deflation. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:725 / 727
页数:3
相关论文
共 50 条
  • [41] Con: A Bronchial Blocker Is Not a Substitute for a Double-Lumen Endobronchial Tube
    Brodsky, Jay B.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2015, 29 (01) : 237 - 239
  • [42] Double lumen tube and bronchial blocker in thoracic surgery
    Palau Marti, Cristian
    Rubio-Haro, Ruben
    Granell Gil, Manuel
    de Andres Ibanez, Jose
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 340 - 341
  • [43] SAFETY FEATURES OF A NEW DOUBLE-LUMEN ENDOTRACHEAL-TUBE IN THORACIC-SURGERY
    BURTON, NA
    WATSON, DC
    BRODSKY, JB
    MARK, JBD
    CHEST, 1981, 80 (03) : 354 - 354
  • [44] Conservative Management of an Iatrogenic Left Bronchial Injury Following Double-Lumen Endotracheal Tube Placement
    Guru, S.
    Assaad, M.
    Saththasivam, P.
    Siddiqui, F.
    McElhaney, N.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [45] INADVERTENT RELOCATION OF A DOUBLE-LUMEN ENDOTRACHEAL-TUBE BY SURGICAL TRACTION
    PESCOD, DC
    FERNANDES, JK
    ANAESTHESIA AND INTENSIVE CARE, 1994, 22 (06) : 720 - 722
  • [46] Difficult ventilation with a double-lumen endotracheal tube: An unusual manufacturing defect
    Chen, HS
    Jawan, B
    Tseng, CC
    Cheng, KW
    Wang, CH
    ANESTHESIA AND ANALGESIA, 2005, 101 (04): : 1094 - 1097
  • [47] Endotracheal kinking of a double-lumen tube: a potential complication of inappropriate size tube selection
    Ambrosio, Claudia
    Leykin, Yigal
    Pellis, Tommaso
    Brodsky, Jay B.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2011, 28 (08) : 607 - 608
  • [48] Bronchial blocker compared to double-lumen tube for one-lung ventilation during thoracoscopy
    Bauer, C
    Winter, C
    Hentz, JG
    Ducrocq, X
    Steib, A
    Dupeyron, JP
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (02) : 250 - 254
  • [49] Is there a better right-sided tube for one-lung ventilation? A comparison of the right-sided double-lumen tube with the single-lumen tube with right-sided enclosed bronchial blocker
    Campos, JH
    Massa, FC
    ANESTHESIA AND ANALGESIA, 1998, 86 (04): : 696 - 700
  • [50] Difficult Double-Lumen Endotracheal Tube Placement Complicated by an Intraoperative Pneumothorax
    Neelankavil, Jacques
    Salehi, Ali
    Canales, Cecilia
    Stiegler, Marjorie
    SIMULATION IN HEALTHCARE, 2012, 7 (02) : 127 - 132