Lung isolation during port-access cardiac surgery: Double-lumen endotracheal tube versus single-lumen endotracheal tube with a bronchial blocker

被引:21
|
作者
Grocott, HP
Darrow, TR
Whiteheart, DL
Glower, DD
Smith, MS
机构
[1] Duke Univ, Med Ctr, Dept Anesthesiol, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Surg, Durham, NC 27710 USA
关键词
one-lung ventilation; double-lumen endotracheal; tube; bronchial blocker; port-access cardiac surgery;
D O I
10.1053/j.jvca.2003.09.012
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The purpose of this study was to compare the use of a double-lumen endotracheal tube to a single-lumen tube combined with a bronchial blocker for lung isolation during Port-Access cardiac surgery. Design: Prospective, randomized, controlled trial. Setting: Tertiary care university hospital. Participants: Thirty-two patients undergoing Port-Access cardiac surgery via a right minithoracotomy. Interventions: Patients were randomized to intubation with either a left-sided double-lumen tube (double-lumen group) or a single-lumen tube with concomitant use of a bronchial blocker (blocker group). Comparisons between groups included (1) intubation time, (2) number of laryngoscopy attempts, (3) time required for tube exchange at the end of the operation, and (4) surgical satisfaction with the lung deflation (1-5 scale: 5 = excellent). Measurements and Main Results: The initial intubation time was similar between groups (118 82 seconds, double-lumen v 144 +/- 32 seconds, blocker; P = 0.2781). An additional 105 +/- 37 seconds was needed to exchange the double-lumen tube at the end of the operation. The double-lumen group also required more laryngoscopy attempts compared with the blocker group (2.3 +/- 0.6, double-lumen v 1.1 +/- 0.4, blocker; p = 0.0001). The lung deflation was better in the double-lumen group (5 [4-5], double-lumen v 4 [3-5], blocker, p = 0.0414). Conclusions: Compared with a single-lumen tube/bronchial blocker combination the double-lumen endotracheal tube required more laryngoscopy attempts and additional time to replace the tube at the end of the case but resulted in slightly better overall lung deflation. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:725 / 727
页数:3
相关论文
共 50 条
  • [31] Retraction Note: Bronchial blocker versus double-lumen endobronchial tube in minimally invasive cardiac surgery
    Chuncheng Zhang
    Jing Yue
    Mingyue Li
    Wei Jiang
    Yu Pan
    Zhimin Song
    Cailian Shi
    Weixuan Fan
    Zhenxiang Pan
    BMC Pulmonary Medicine, 20
  • [32] RETRACTED ARTICLE: Bronchial blocker versus double-lumen endobronchial tube in minimally invasive cardiac surgery
    Chuncheng Zhang
    Jing Yue
    Mingyue Li
    Wei Jiang
    Yu Pan
    Zhimin Song
    Cailian Shi
    Weixuan Fan
    Zhenxiang Pan
    BMC Pulmonary Medicine, 19
  • [33] Lung separation in critically ill patients:: Is the Arndt Endobronchial Blocker® an alternative to a double-lumen endotracheal tube?
    Lischke, V
    Mierdl, S
    Westphal, K
    Meininger, D
    Byhahn, C
    ANESTHESIOLOGY, 2002, 97 (03) : B27 - B27
  • [34] Use of Capnography to Identify a Malpositioned Double-Lumen Endotracheal Tube
    Sen, Barsha
    Panidapu, Nagarjuna
    Micka, Rohik
    Neema, Praveen Kumar
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (05) : 1287 - 1288
  • [35] Unusual case of difficult double-lumen endotracheal tube removal
    Yazbek-Karam, Vanda G.
    Haswani, Roula W.
    Karam, Hoda S.
    Haddad, Walid M.
    Youssef, Pierre S.
    Hachem, Boutros F.
    Atik, Fouad T.
    Rassi, Simon J.
    Yammine, Joseph N.
    Baraka, Anis S.
    Aouad, Marie T.
    JOURNAL OF CLINICAL ANESTHESIA, 2009, 21 (07) : 514 - 516
  • [36] BRONCHOSCOPIC PLACEMENT OF THE DOUBLE-LUMEN ENDOTRACHEAL-TUBE FOR INDEPENDENT LUNG VENTILATION
    SHAPIRO, S
    WATSON, CB
    BOWE, EA
    KLEIN, EF
    CRITICAL CARE MEDICINE, 1981, 9 (03) : 189 - 189
  • [37] Incidence of difficulties encountered during double-lumen endotracheal tube (DLT) insertion
    Galazoula, H.
    Anagnostopoulou, M.
    Papamichael, K.
    Malachias, T.
    Voyagis, G.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (01) : 275 - 276
  • [38] RETRACTED: Bronchial blocker versus double-lumen endobronchial tube in minimally invasive cardiac surgery (Retracted Article)
    Zhang, Chuncheng
    Yue, Jing
    Li, Mingyue
    Jiang, Wei
    Pan, Yu
    Song, Zhimin
    Shi, Cailian
    Fan, Weixuan
    Pan, Zhenxiang
    BMC PULMONARY MEDICINE, 2019, 19 (01)
  • [39] Video-assisted thoracoscopic surgery using single-lumen endotracheal tube anesthesia
    Cerfolio, RJ
    Bryant, AS
    Sheils, TM
    Bass, CS
    Bartolucci, AA
    CHEST, 2004, 126 (01) : 281 - 285
  • [40] Selective lobar blockade with a Coopdech blocker combined with a double-lumen endotracheal tube for lung metastases resection by laser
    Cruz, Patricia
    David Orozco, Hugo
    Garutti Martinez, Ignacio
    Hernandez Fernandez, Gloria
    REVISTA BRASILEIRA DE ANESTESIOLOGIA, 2018, 68 (02): : 200 - 204