Comparing cardiac output measurements using electrical cardiometry versus phase contrast cardiac magnetic resonance imaging

被引:1
|
作者
Sumbel, Lydia [1 ]
Nagaraju, Lakshmi [2 ]
Ogbeifun, Henry [1 ]
Agarwal, Arpit [1 ,3 ]
Bhalala, Utpal [4 ,5 ,6 ,7 ]
机构
[1] Childrens Hosp San Antonio, San Antonio, TX USA
[2] UC Davis Childrens Hosp, Sacramento, CA USA
[3] Baylor Coll Med, Houston, TX USA
[4] Driscoll Childrens Hosp, Corpus Christi, TX USA
[5] Texas A&M Univ, College Stn, TX USA
[6] Univ Texas Med Branch, Galveston, TX USA
[7] Texas A&M Univ, Univ Texas Med Branch UTMB, Pediat & Cardiac Intensivist Driscoll Childrens Ho, Res Advisor & Founding Chair Res Taskforce Hlth Sy, 3533 S Almeda St, Corpus Christi, TX 78411 USA
关键词
Cardiac output; Electrical Cardiometry; Magnetic resonance imaging; Children; VELOCIMETRY; HEART; PRECISION; ACCURACY; CHILDREN;
D O I
10.1016/j.ppedcard.2022.101551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: There is a growing interest in using non-invasive electrical cardiometry (EC) for continuous cardiac output (CO) measurements in neonates and children. There is a lack of sufficient data to validate CO measured by EC with currently accepted noninvasive techniques such as cardiac MRI (CMRI) in children. Objectives: To assess the degree of agreement between CO measured by EC and CMRI in children. We hypothesized that there is a good degree of agreement between CO measured by EC and CMRI in children. Methods: A retrospective chart review was performed to include patients who had noninvasive CO measured using EC (ICON (R)) and CMRI at our children's hospital between Feb 2019 and May 2020. Anthropometric, clinical and CO data were collected and CMRI parameters such as flow measurements in the aorta and pulmonary artery were analyzed. Data was analyzed using a Bland-Altman plot to compare the agreement between the CO obtained by EC vs. CMRI in this cohort of patients. Results: A total of 52 patients with cardiac disease who had data available from CMRI and ICON (R) were included. The median (IQR) age was 174 (99,201) months and male: female ratio was 1.2:1. A total of 34/52 (60 %) patients had congenital heart disease and 22 had history of surgical interventions prior to noninvasive CO measurements. The Bland-Altman analysis for CO values by both EC and CMRI produced a mean bias (SD) of 0.12 (2.73)1/min for ICON (R) and the 95 % limits of agreement were -5.229 to 5.473 1/min. The precision error was only 1.86 %. The Bland- Altman plot for reproducibility for CO values by EC produced a mean bias (SD) of 0.15 (0.41) 1/min with limits of agreement of -0.66 to 0.97 1/min. The percentage error was 2.34 %. Conclusions: In our cohort of cardiac patients, there was a good degree of agreement between noninvasive CO as measured by Electric Cardiometry and Cardiac MRI.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Decreased cardiac output in septic mice as assessed by magnetic resonance imaging
    Levy, RJ
    Yoo, C
    Zhou, R
    Ferrari, VA
    Deutschman, CS
    CRITICAL CARE MEDICINE, 2003, 31 (12) : A31 - A31
  • [42] The Use of Electrical Cardiometry for Continuous Cardiac Output Monitoring in Preterm Neonates: A Validation Study
    Song, R.
    Rich, W.
    Kim, J. H.
    Finer, N. N.
    Katheria, A. C.
    AMERICAN JOURNAL OF PERINATOLOGY, 2014, 31 (12) : 1105 - 1109
  • [43] Changes in cardiac index four months after STEMI-A phase-contrast cardiac magnetic resonance imaging study
    Schwaiger, J.
    Reinstadler, S. J.
    Holzknecht, M.
    Tiller, C.
    Reindl, M. Begle J.
    Lechner, I
    Mayr, A.
    Graziadei, I
    Bauer, A.
    Metzler, B.
    Klug, G.
    WIENER KLINISCHE WOCHENSCHRIFT, 2022, 134 (SUPPL 2) : 156 - 156
  • [44] Velocity and volume flow rate measurements using phase contrast magnetic resonance imaging
    Korosec, FR
    Turski, PA
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1997, 3 (04): : 293 - 318
  • [45] Transthoracic Impedance Compared to Magnetic Resonance Imaging in the Assessment of Cardiac Output
    Villacorta Junior, Humberto
    Villacorta, Aline Sterque
    Amador, Fernanda
    Hadlich, Marcelo
    de Albuquerque, Denilson Campos
    Azevedo, Clerio Francisco
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2012, 99 (06) : 1149 - 1154
  • [46] Electrical Cardiometry: A Reliable Solution to Cardiac Output Estimation in Children With Structural Heart Disease
    Narula, Jitin
    Chauhan, Sandeep
    Ramakrishnan, Sivasubramanian
    Gupta, Saurabh Kumar
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2017, 31 (03) : 912 - 917
  • [47] Nanoparticles as magnetic resonance imaging contrast agents for vascular and cardiac diseases
    Chen, Wei
    Cormode, David P.
    Fayad, Zahi A.
    Mulder, Willem J. M.
    WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY, 2011, 3 (02) : 146 - 161
  • [48] Cardiac sarcoidosis:: Diagnosis by contrast-enhanced magnetic resonance imaging
    Garcia-Gallego, Francisco
    Bret-Zurita, Montserrat
    Garcia-Quero, Cristina
    Cuesta-Lopez, Emilio
    REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (07): : 784 - 786
  • [49] CARDIAC MAGNETIC RESONANCE IMAGING WITH CONTRAST ENHANCEMENT IN TREATMENT OF ATRIAL FIBRILLATION
    Aparina, O. P.
    Mironov, N. Y.
    Fedorova, E. A.
    Dzaurova, K. M.
    Maykov, E. B.
    Stukalova, O., V
    Golitsyn, S. P.
    KARDIOLOGIYA, 2020, 60 (03) : 119 - 125
  • [50] Noninvasive cardiac output monitoring during anaesthesia and surgery in young children using electrical cardiometry: an observational study
    Falciola, Veronique
    Donath, Susan M.
    Roden, Emilie
    Davidson, Andrew
    Vutskits, Laszlo
    BRITISH JOURNAL OF ANAESTHESIA, 2022, 128 (03) : E235 - E238