Comparing cardiac output measurements using electrical cardiometry versus phase contrast cardiac magnetic resonance imaging

被引:1
|
作者
Sumbel, Lydia [1 ]
Nagaraju, Lakshmi [2 ]
Ogbeifun, Henry [1 ]
Agarwal, Arpit [1 ,3 ]
Bhalala, Utpal [4 ,5 ,6 ,7 ]
机构
[1] Childrens Hosp San Antonio, San Antonio, TX USA
[2] UC Davis Childrens Hosp, Sacramento, CA USA
[3] Baylor Coll Med, Houston, TX USA
[4] Driscoll Childrens Hosp, Corpus Christi, TX USA
[5] Texas A&M Univ, College Stn, TX USA
[6] Univ Texas Med Branch, Galveston, TX USA
[7] Texas A&M Univ, Univ Texas Med Branch UTMB, Pediat & Cardiac Intensivist Driscoll Childrens Ho, Res Advisor & Founding Chair Res Taskforce Hlth Sy, 3533 S Almeda St, Corpus Christi, TX 78411 USA
关键词
Cardiac output; Electrical Cardiometry; Magnetic resonance imaging; Children; VELOCIMETRY; HEART; PRECISION; ACCURACY; CHILDREN;
D O I
10.1016/j.ppedcard.2022.101551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: There is a growing interest in using non-invasive electrical cardiometry (EC) for continuous cardiac output (CO) measurements in neonates and children. There is a lack of sufficient data to validate CO measured by EC with currently accepted noninvasive techniques such as cardiac MRI (CMRI) in children. Objectives: To assess the degree of agreement between CO measured by EC and CMRI in children. We hypothesized that there is a good degree of agreement between CO measured by EC and CMRI in children. Methods: A retrospective chart review was performed to include patients who had noninvasive CO measured using EC (ICON (R)) and CMRI at our children's hospital between Feb 2019 and May 2020. Anthropometric, clinical and CO data were collected and CMRI parameters such as flow measurements in the aorta and pulmonary artery were analyzed. Data was analyzed using a Bland-Altman plot to compare the agreement between the CO obtained by EC vs. CMRI in this cohort of patients. Results: A total of 52 patients with cardiac disease who had data available from CMRI and ICON (R) were included. The median (IQR) age was 174 (99,201) months and male: female ratio was 1.2:1. A total of 34/52 (60 %) patients had congenital heart disease and 22 had history of surgical interventions prior to noninvasive CO measurements. The Bland-Altman analysis for CO values by both EC and CMRI produced a mean bias (SD) of 0.12 (2.73)1/min for ICON (R) and the 95 % limits of agreement were -5.229 to 5.473 1/min. The precision error was only 1.86 %. The Bland- Altman plot for reproducibility for CO values by EC produced a mean bias (SD) of 0.15 (0.41) 1/min with limits of agreement of -0.66 to 0.97 1/min. The percentage error was 2.34 %. Conclusions: In our cohort of cardiac patients, there was a good degree of agreement between noninvasive CO as measured by Electric Cardiometry and Cardiac MRI.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Baseline correction of phase-contrast images in congenital Cardiac Magnetic Resonance Imaging
    Brian J Holland
    Beth F Printz
    Wyman W Lai
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [22] DETERMINATION OF CARDIAC-OUTPUT BY MAGNETIC-RESONANCE-IMAGING
    MOGELVANG, J
    STAHLBERG, F
    SONDERGARD, L
    THOMSEN, C
    LINDVIG, K
    HENRIKSEN, O
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1992, 6 (03): : 201 - 204
  • [23] ROLE OF MAGNETIC-RESONANCE CONTRAST AGENTS IN CARDIAC IMAGING
    WOLF, GL
    AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (14): : F59 - F62
  • [24] A NOVEL METHOD FOR INTERNAL VALIDATION OF AORTIC FLOW USING PHASE-CONTRAST CARDIAC MAGNETIC RESONANCE IMAGING
    Samanta, Anweshan
    Soltys, Joseph
    Patil, Harshal
    Saeed, Ibrahim
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1602 - 1602
  • [25] Planimetry of the Orifice Area in Aortic Valve Stenosis Using Phase-Contrast Cardiac Magnetic Resonance Imaging
    Abe, Hajime
    Iguchi, Nobuo
    Utanohara, Yuko
    Takada, Kaori
    Hen, Yasuki
    Machida, Haruhiko
    Takeda, Norihiko
    Sumiyoshi, Tetsuya
    INTERNATIONAL HEART JOURNAL, 2018, 59 (01) : 77 - 80
  • [26] Cardiac magnetic resonance imaging study for quantification of infarct size comparing directly serial versus single time-point measurements of cardiac troponin T
    Giannitsis, Evangelos
    Steen, Henning
    Kurz, Kerstin
    Ivandic, Boris
    Simon, Anke C.
    Futterer, Simon
    Schild, Christian
    Isfort, Peter
    Jaffe, Allan S.
    Katus, Hugo A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (03) : 307 - 314
  • [27] Strain imaging using cardiac magnetic resonance
    A. Scatteia
    A. Baritussio
    C. Bucciarelli-Ducci
    Heart Failure Reviews, 2017, 22 : 465 - 476
  • [28] Strain imaging using cardiac magnetic resonance
    Scatteia, A.
    Baritussio, A.
    Bucciarelli-Ducci, C.
    HEART FAILURE REVIEWS, 2017, 22 (04) : 465 - 476
  • [29] Randomised trial comparing standard versus thermocontrolled haemodialysis using intradialytic cardiac, brain and renal magnetic resonance imaging
    Gullapudi, Venkata R. Latha
    Cox, Eleanor F.
    Buchanan, Charlotte E.
    Canaud, Bernard
    White, Kelly
    Taal, Maarten W.
    Selby, Nicholas M.
    Francis, Susan T.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2024, 39 (02) : 233 - 241
  • [30] Cardiac Magnetic Resonance Imaging of Cardiac Amyloidosis
    Chao, Robert
    Ivanov, Alexander
    Efthimiou, Petros
    JCR-JOURNAL OF CLINICAL RHEUMATOLOGY, 2019, 25 (05) : E59 - E60