Comparing cardiac output measurements using electrical cardiometry versus phase contrast cardiac magnetic resonance imaging

被引:1
|
作者
Sumbel, Lydia [1 ]
Nagaraju, Lakshmi [2 ]
Ogbeifun, Henry [1 ]
Agarwal, Arpit [1 ,3 ]
Bhalala, Utpal [4 ,5 ,6 ,7 ]
机构
[1] Childrens Hosp San Antonio, San Antonio, TX USA
[2] UC Davis Childrens Hosp, Sacramento, CA USA
[3] Baylor Coll Med, Houston, TX USA
[4] Driscoll Childrens Hosp, Corpus Christi, TX USA
[5] Texas A&M Univ, College Stn, TX USA
[6] Univ Texas Med Branch, Galveston, TX USA
[7] Texas A&M Univ, Univ Texas Med Branch UTMB, Pediat & Cardiac Intensivist Driscoll Childrens Ho, Res Advisor & Founding Chair Res Taskforce Hlth Sy, 3533 S Almeda St, Corpus Christi, TX 78411 USA
关键词
Cardiac output; Electrical Cardiometry; Magnetic resonance imaging; Children; VELOCIMETRY; HEART; PRECISION; ACCURACY; CHILDREN;
D O I
10.1016/j.ppedcard.2022.101551
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: There is a growing interest in using non-invasive electrical cardiometry (EC) for continuous cardiac output (CO) measurements in neonates and children. There is a lack of sufficient data to validate CO measured by EC with currently accepted noninvasive techniques such as cardiac MRI (CMRI) in children. Objectives: To assess the degree of agreement between CO measured by EC and CMRI in children. We hypothesized that there is a good degree of agreement between CO measured by EC and CMRI in children. Methods: A retrospective chart review was performed to include patients who had noninvasive CO measured using EC (ICON (R)) and CMRI at our children's hospital between Feb 2019 and May 2020. Anthropometric, clinical and CO data were collected and CMRI parameters such as flow measurements in the aorta and pulmonary artery were analyzed. Data was analyzed using a Bland-Altman plot to compare the agreement between the CO obtained by EC vs. CMRI in this cohort of patients. Results: A total of 52 patients with cardiac disease who had data available from CMRI and ICON (R) were included. The median (IQR) age was 174 (99,201) months and male: female ratio was 1.2:1. A total of 34/52 (60 %) patients had congenital heart disease and 22 had history of surgical interventions prior to noninvasive CO measurements. The Bland-Altman analysis for CO values by both EC and CMRI produced a mean bias (SD) of 0.12 (2.73)1/min for ICON (R) and the 95 % limits of agreement were -5.229 to 5.473 1/min. The precision error was only 1.86 %. The Bland- Altman plot for reproducibility for CO values by EC produced a mean bias (SD) of 0.15 (0.41) 1/min with limits of agreement of -0.66 to 0.97 1/min. The percentage error was 2.34 %. Conclusions: In our cohort of cardiac patients, there was a good degree of agreement between noninvasive CO as measured by Electric Cardiometry and Cardiac MRI.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] CARDIAC OUTPUT MEASUREMENTS USING ELECTRICAL CARDIOGRAPHY VERSUS PHASE CONTRAST CARDIAC MRI
    Sumbel, Lydia
    Ogbeifun, Henry
    Agarwal, Arpit
    Bhalala, Utpal
    CRITICAL CARE MEDICINE, 2021, 49 (01) : 203 - 203
  • [2] Cardiac Output in Preterm Infants Using Electrical Cardiometry
    Ow, R.
    De Water, J. Van
    Bozeman, A.
    Smith-Weaver, B.
    Rodriguez, M.
    Ho, B.
    Ashley, D. W.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [3] Trending ability of cardiac output measurements using electrical cardiometry during abdominal surgery
    Servaas, Sjoerd
    van Eijk, Lucas T.
    Malagon, Ignacio
    Slagt, Cornelis
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2022, 39 (07) : 619 - 622
  • [4] COMPARISON OF CARDIAC OUTPUT MEASUREMENTS BETWEEN ELECTRICAL CARDIOMETRY (EC) AND ECHOCARDIOGRAPHY
    Cayabyab, R. G.
    Bhombal, S.
    Ebrahimi, M.
    Seri, I
    JOURNAL OF INVESTIGATIVE MEDICINE, 2011, 59 (01) : 125 - 125
  • [5] Quantification of Cardiac Output with Phase Contrast Magnetic Resonance Imaging in Patients with Pulmonary Hypertension
    Po, Jose Ricardo
    Tong, Matthew
    Meeran, Talha
    Potluri, Alekhya
    Raina, Amresh
    Doyle, Mark
    Biederman, Robert
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2020, 10
  • [6] Contrast - in cardiac magnetic resonance imaging
    Patel, Nirav
    Kolakalapudi, Pavani
    Arora, Garima
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2018, 35 (03): : 401 - 409
  • [7] Comparison of bioreactance non-invasive cardiac output measurements with cardiac magnetic resonance imaging
    Trinkmann, F.
    Schneider, C.
    Michels, J. D.
    Stach, K.
    Doesch, C.
    Schoenberg, S. O.
    Borggrefe, M.
    Saur, J.
    Papavassiliu, T.
    ANAESTHESIA AND INTENSIVE CARE, 2016, 44 (06) : 769 - 776
  • [8] Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output
    Frederik Trinkmann
    Manuel Berger
    Christina Doesch
    Theano Papavassiliu
    Stefan O. Schoenberg
    Martin Borggrefe
    Jens J. Kaden
    Joachim Saur
    Journal of Clinical Monitoring and Computing, 2016, 30 : 399 - 408
  • [9] Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output
    Trinkmann, Frederik
    Berger, Manuel
    Doesch, Christina
    Papavassiliu, Theano
    Schoenberg, Stefan O.
    Borggrefe, Martin
    Kaden, Jens J.
    Saur, Joachim
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2016, 30 (04) : 399 - 408
  • [10] Cardiac magnetic resonance haemodynamics in paediatric heart transplant patients: fick oximetry versus cardiac magnetic resonance phase contrast
    Schramm, Jennifer
    Cronin, Ileen
    McCarter, Robert
    Mandell, Jason G. G.
    Downing, Tacy
    Kanter, Joshua
    Cross, Russell
    Olivieri, Laura
    CARDIOLOGY IN THE YOUNG, 2024, 34 (02) : 262 - 267