Analysis of Proteins, Protein Complexes, and Organellar Proteomes Using Sheathless Capillary Zone Electrophoresis - Native Mass Spectrometry

被引:70
|
作者
Belov, Arseniy M. [1 ]
Viner, Rosa [2 ]
Santos, Marcia R. [3 ]
Horn, David M. [2 ]
Bern, Marshall [4 ]
Karger, Barry L. [1 ]
Ivanov, Alexander R. [1 ]
机构
[1] Northeastern Univ, Barnett Inst Chem & Biol Anal, Boston, MA 02115 USA
[2] Thermo Fisher Sci, San Jose, CA 95134 USA
[3] SCIEX Ltd, Brea, CA 92821 USA
[4] Prot Metr, San Carlos, CA 94070 USA
关键词
Capillary zone electrophoresis; Sheathless CZE-MS; Native mass spectrometry; Top-down mass spectrometry; Ultra-low flow separations; Protein complexes; Ribosome; Specialized ribosomes; Proteoform; Aggregation of biopharmaceutical proteins; FIELD-FLOW FRACTIONATION; ESCHERICHIA-COLI; RIBOSOMAL-PROTEINS; YEAST ENOLASE; GAS-PHASE; LIQUID-CHROMATOGRAPHY; MONOCLONAL-ANTIBODY; STRUCTURAL BASIS; SEPARATION; MS;
D O I
10.1007/s13361-017-1781-1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Native mass spectrometry (MS) is a rapidly advancing field in the analysis of proteins, protein complexes, and macromolecular species of various types. The majority of native MS experiments reported to-date has been conducted using direct infusion of purified analytes into a mass spectrometer. In this study, capillary zone electrophoresis (CZE) was coupled online to Orbitrap mass spectrometers using a commercial sheathless interface to enable high-performance separation, identification, and structural characterization of limited amounts of purified proteins and protein complexes, the latter with preserved non-covalent associations under native conditions. The performance of both bare-fused silica and polyacrylamide-coated capillaries was assessed using mixtures of protein standards known to form non-covalent protein-protein and protein-ligand complexes. High-efficiency separation of native complexes is demonstrated using both capillary types, while the polyacrylamide neutral-coated capillary showed better reproducibility and higher efficiency for more complex samples. The platform was then evaluated for the determination of monoclonal antibody aggregation and for analysis of proteomes of limited complexity using a ribosomal isolate from E. coli. Native CZE-MS, using accurate single stage and tandem-MS measurements, enabled identification of proteoforms and non-covalent complexes at femtomole levels. This study demonstrates that native CZE-MS can serve as an orthogonal and complementary technique to conventional native MS methodologies with the advantages of low sample consumption, minimal sample processing and losses, and high throughput and sensitivity. This study presents a novel platform for analysis of ribosomes and other macromolecular complexes and organelles, with the potential for discovery of novel structural features defining cellular phenotypes (e.g., specialized ribosomes).
引用
收藏
页码:2614 / 2634
页数:21
相关论文
共 50 条
  • [1] Sheathless preconcentration-capillary zone electrophoresis-mass spectrometry applied to peptide analysis
    Barroso, MB
    de Jong, AP
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) : 1271 - 1278
  • [2] Analysis of intact venom proteins with capillary zone electrophoresis - mass spectrometry
    Vishwakarma, Gayatri
    Andrasi, Melinda
    Szabo, Ruben
    Hajdu, Peter
    Petrilla, Vladimir
    Petrillova, Monika
    Legath, Jaroslav
    Gaspar, Attila
    MICROCHEMICAL JOURNAL, 2024, 200
  • [3] Detection and analysis of protein-protein interactions in organellar and prokaryotic proteomes by native gel electrophoresis: (Membrane) protein complexes and supercomplexes
    Krause, Frank
    ELECTROPHORESIS, 2006, 27 (13) : 2759 - 2781
  • [4] Native Proteomics by Capillary Zone Electrophoresis-Mass Spectrometry
    Wang, Qianyi
    Wang, Qianjie
    Qi, Zihao
    Moeller, William
    Wysocki, Vicki H.
    Sun, Liangliang
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2024, 63 (48)
  • [5] Analysis of peptides, proteins, protein digests, and whole human blood by capillary electrophoresis electrospray ionization mass spectrometry using an in-capillary electrode sheathless interface
    Cao, P
    Moini, M
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (10) : 1081 - 1088
  • [6] Analysis of gangliosides by capillary zone electrophoresis and capillary zone electrophoresis electrospray mass spectrometry
    Ju, DD
    Lai, CC
    Her, GR
    JOURNAL OF CHROMATOGRAPHY A, 1997, 779 (1-2) : 195 - 203
  • [7] Analysis of butterfly reproductive proteins using capillary electrophoresis and mass spectrometry
    Rokhas, Maria Khihon
    Ronn, Johanna Liljestrand
    Wiklund, Christer
    Emmer, Asa
    ANALYTICAL BIOCHEMISTRY, 2019, 566 : 23 - 26
  • [8] Sheathless capillary electrophoresis-mass spectrometry using a pulsed electrospray ionization source
    Chao, Bing-Fong
    Chen, Chao-Jung
    Li, Fu-An
    Her, Guor-Rong
    ELECTROPHORESIS, 2006, 27 (11) : 2083 - 2090
  • [9] Analysis of metallothioneins by means of capillary electrophoresis coupled to electrospray mass spectrometry with sheathless interfacing
    Guo, X
    Chan, HM
    Guevremont, R
    Siu, KWM
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (06) : 500 - 507
  • [10] Analysis of glyphosate and glufosinate by capillary electrophoresis - mass spectrometry utilising a sheathless microelectrospray interface
    Goodwin, L
    Startin, JR
    Keely, BJ
    Goodall, DM
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1004 (1-2) : 107 - 119