Measurement of glomerular filtration rate in patients undergoing obesity surgery

被引:10
|
作者
Chuah, Ling L. [1 ]
Miras, Alexander D. [1 ]
Perry, Laura M. [2 ]
Frankel, Andrew H. [3 ]
Towey, David J. [2 ]
Al-Mayahi, Zahraa [1 ]
Svensson, William [4 ]
le Roux, Carel W. [1 ,5 ,6 ]
机构
[1] Imperial Coll London, Sect Invest Med, Hammersmith Hosp, 6th Floor,Commonwealth Bldg,Du Cane Rd, London W12 0NN, England
[2] Imperial Coll Healthcare NHS Trust, Radiol Sci Unit, London, England
[3] Imperial Coll Healthcare NHS Trust, Nephrol, London, England
[4] Imperial Coll Healthcare NHS Trust, Nucl Med, London, England
[5] Univ Gothenburg, Gastro Surg Lab, Gothenburg, Sweden
[6] Univ Coll Dublin, Conway Inst, Diabet Complicat Res Ctr, Dublin, Ireland
来源
BMC NEPHROLOGY | 2018年 / 19卷
基金
爱尔兰科学基金会;
关键词
Renal; Creatinine; Bariatric; Cr-EDTA; GFR; BARIATRIC SURGERY; FORMULA; GFR;
D O I
10.1186/s12882-018-1188-7
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
BackgroundMost studies on obesity surgery have measured renal function using the estimated GFR. However, due to the reduction of muscle mass, and therefore creatinine that accompanies weight loss, such measures can falsely suggest an improvement in renal function. To balance the risks of surgery versus any potential benefits on renal function, we need to be able to determine renal function using valid and reliable methodologies. In this pilot study we aimed to measure renal function in patients with CKD undergoing obesity surgery using the gold standard Cr-51-EDTA GFR clearance methodology which is independent of measures of muscle mass.MethodsNine consecutive obese patients with CKD underwent obesity surgery. Their renal function was assessed using Cr-51-EDTA GFR, cystatin C and serum creatinine as well as using eGFR equations including MDRD CKD Epi, Cockcroft Gault and CKD Epi cystatin before and 12months after surgery.ResultsRenal function using the Cr-51-EDTA measured GFR did not change significantly after surgery. Similar results were obtained when Cystatin C, CKD Epi cystatin, CKD Epi cystatin creatinine and adjusted Cockcroft Gault Creatinine clearance methods were used. In contrast there were either trends or significant improvements in renal function measured using the MDRD and CKD Epi equations.ConclusionsIn this pilot study using the gold standard Cr-51-EDTA method we found stabilisation in renal function after obesity surgery. Until further definitive data emerge it is critical to balance the risk and benefits of surgery, especially if renal function may not improve as often as previously suggested.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] PREDICTORS OF FALL IN GLOMERULAR FILTRATION RATE IN PATIENTS UNDERGOING CORONARY ARTERY BYPASS GRAFTING
    Reddy, Sai Ram Keithi
    Gopichand, M.
    Sajja, Lokeshwar Rao
    Hussaini, M. Shaista
    Devi, Sita
    Naidu, Shanti
    Chakravarthi, R.
    NEPHROLOGY, 2005, 10 : A107 - A107
  • [42] Accurate measurement of individual glomerular filtration rate in cancer patients: an ongoing challenge
    Holweger, K
    Bokemeyer, C
    Lipp, HP
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2005, 131 (09) : 559 - 567
  • [43] Accurate measurement of individual glomerular filtration rate in cancer patients: an ongoing challenge
    Karin Holweger
    Carsten Bokemeyer
    Hans-Peter Lipp
    Journal of Cancer Research and Clinical Oncology, 2005, 131 : 559 - 567
  • [44] A prospective study to compare the measured glomerular filtration rate compared to estimated glomerular filtration rate in patients undergoing definitive chemoradiation, with platinum agents for various malignancies
    Rudresh, A. H.
    Asati, Vikas
    Lakshmaiah, K. C.
    Lokanatha, D.
    Babu, Suresh
    Rajeev, L. K.
    Lokesh, K. N.
    Babu, Govind
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 : S56 - S59
  • [45] MEASUREMENT OF GLOMERULAR-FILTRATION RATE IN CONSCIOUS HUMMINGBIRDS
    MEDLER, S
    BEUCHAT, C
    AMERICAN ZOOLOGIST, 1991, 31 (05): : A44 - A44
  • [46] UK audit of glomerular filtration rate measurement in 2001
    Cosgriff, Philip S.
    Fleming, John S.
    Jarritt, Peter H.
    Skrypniuk, John
    Bailey, Dale
    Whalley, Dave
    Houston, Alex
    Burniston, Maria
    Blake, Glen M.
    NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (06) : 511 - 520
  • [47] PHYSIOLOGICAL TIME AND THE MEASUREMENT OF GLOMERULAR-FILTRATION RATE
    MEDLER, S
    JOURNAL OF THEORETICAL BIOLOGY, 1995, 176 (01) : 59 - 65
  • [48] Measurement of glomerular filtration rate using a reference method
    Chardon, Laurence
    Dubourg, Laurence
    Barin-Le Guellec, Chantal
    Guinard, Francis
    Hannedouche, Thierry
    Halimi, Jean-Michel
    Mariat, Christophe
    ANNALES DE BIOLOGIE CLINIQUE, 2019, 77 (04) : 371 - 374
  • [49] INTEGRAL APPROACH TO MEASUREMENT OF GLOMERULAR FILTRATION-RATE
    MALOWANY, AS
    HARRIES, JD
    MILDENBERGER, RR
    MEDICAL & BIOLOGICAL ENGINEERING, 1973, 11 (05): : 579 - 583
  • [50] Estimating Analytical Errors of Glomerular Filtration Rate Measurement
    Ognissanti, Damiano
    Andresen Bergstrom, Moa
    Theodorsson, Elvar
    Larsson, Anders
    Nordin, Gunnar
    Hammarsten, Ola
    CLINICAL CHEMISTRY, 2022, 68 (09) : 1211 - 1218