Estimating Analytical Errors of Glomerular Filtration Rate Measurement

被引:2
|
作者
Ognissanti, Damiano [1 ,2 ]
Andresen Bergstrom, Moa [3 ,4 ]
Theodorsson, Elvar [5 ]
Larsson, Anders [6 ]
Nordin, Gunnar [7 ]
Hammarsten, Ola [3 ,4 ]
机构
[1] Chalmers Univ Technol, Dept Math Sci, Gothenburg, Sweden
[2] Univ Gothenburg, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Clin Chem, Gothenburg, Sweden
[4] Univ Gothenburg, Inst Biomed, Dept Lab Med, Gothenburg, Sweden
[5] Linkoping Univ, Dept Biomed & Clin Sci, Div Clin Chem, Fac Med & Hlth Sci, Linkoping, Sweden
[6] Uppsala Univ, Clin Chem, Dept Med Sci, Uppsala, Sweden
[7] External Qual Assurance Lab Med Sweden EQUALIS, Uppsala, Sweden
关键词
SINGLE-SAMPLE MEASUREMENT; PLASMA-CLEARANCE; RENAL CLEARANCE; CONTRAST AGENT; IOHEXOL; GFR; TIME; UNCERTAINTY; SLOPE;
D O I
10.1093/clinchem/hvac098
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Few studies are available on how to optimize time points for sampling and how to estimate effects of analytical uncertainty when glomerular filtration rate (GFR) is calculated. Methods We explored the underlying regression mathematics of how analytical variation of a kidney filtration marker affects 1-compartment, slope-and-intercept GFR calculations, using 2 or 3 time points following a bolus injection, and used this to examine the results from 731 routine 3-point iohexol plasma clearance measurements. Results GFR calculations inflated analytical uncertainty if the time points were taken too late after the bolus injection and too close after each other. The uncertainty in GFR calculation was, however, the same as the analytical uncertainty if optimal time points were used. The middle of the 3 samples was of little value. The first sample should be taken as early as possible after the distribution phase. Sampling before the patient specific half-life of the kidney filtration marker resulted in an exponential error inflation whereas no error inflation was seen when sampling occurred later than 2 half-lives. Theoretical GFR uncertainty could be lowered 2.6-fold if individually optimized time points for sampling had been used in our 731 clearance measurements. Using Taylor expansions to approximate the moments of transformed random variables, the uncertainty of an individual GFR measurement could be calculated in a simple enough way to be applicable by laboratory software. Conclusions We provide a theoretical foundation to select patient-optimal time points that may both limit errors and allow calculation of GFR uncertainty.
引用
收藏
页码:1211 / 1218
页数:8
相关论文
共 50 条
  • [1] Estimating Analytical Errors of Glomerular Filtration Rate Measurement (vol 68, pg 1211, 2022)
    Ognissanti, Damiano
    Bergstrom, Moa Andresen
    Theodorsson, Elvar
    Larsson, Anders
    Nordin, Gunnar
    Hammarsten, Ola
    [J]. CLINICAL CHEMISTRY, 2023, 69 (04) : 429 - 429
  • [2] Estimating the glomerular filtration rate
    Kelsall, Diane
    [J]. CANADIAN MEDICAL ASSOCIATION JOURNAL, 2012, 184 (09) : 1062 - 1062
  • [3] Estimating glomerular filtration rate
    Miller, W. Greg
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2009, 47 (09) : 1017 - 1019
  • [4] Estimating Glomerular Filtration Rate
    Wagner, Doris
    Zitta, Sabine
    Rosenkranz, Alexander R.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2012, 367 (13): : 1262 - 1263
  • [5] Estimating and measuring glomerular filtration rate: methods of measurement and markers for estimation
    Lamb, Edmund J.
    Stevens, Paul E.
    [J]. CURRENT OPINION IN NEPHROLOGY AND HYPERTENSION, 2014, 23 (03): : 258 - 266
  • [6] Estimating glomerular filtration rate in children
    Ham, HR
    Piepsz, A
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (09) : 1646 - 1646
  • [7] Methods for estimating glomerular filtration rate
    Corsonello, A
    Pedone, C
    Incalzi, RA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2004, 291 (23): : 2819 - 2820
  • [8] ESTIMATING GLOMERULAR FILTRATION-RATE
    AURELL, M
    [J]. LANCET, 1965, 2 (7404): : 188 - &
  • [9] Estimating Glomerular Filtration Rate Reply
    Inker, Lesley A.
    Coresh, Josef
    Levey, Andrew S.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2012, 367 (13): : 1263 - 1264
  • [10] Measurement of glomerular filtration rate
    Gaspari, F
    PerIco, N
    Remuzzi, G
    [J]. KIDNEY INTERNATIONAL, 1997, : S151 - S154