Involuntary Tremor Controlled Using Mechanical Means Involunatry Hand Tremor

被引:0
|
作者
Gebai, Sarah [1 ]
Hammoud, Mohammad [1 ]
Hallal, Ali [1 ]
Shaer, Ali A. L. [1 ]
机构
[1] Int Univ Beirut, Dept Mech Engn, SDM & LIBRA Res Grp, Beirut 146404, Lebanon
关键词
conventional absorber; hand model; Choleskey; time domain; frequency domain; VIBRATION ABSORBER; REST TREMOR; MODEL;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Patients with neurodegenerative disorder suffers from performing their daily tasks resulting in a reduced community ambulation. Tremor is suggested to be reduced by mechanical means using passive vibration controller. Human hand is modeled in the horizontal plane to describe the flexion-extension motion at the shoulder, elbow and wrist joints. Tremor is modeled as sinusoidal function driven at two resonance frequencies with white Gaussian noise added to the signal. Equations of motion are derived and solved using the fourth order Runge-Kutta method for the controlled dynamically coupled systems. The two DOF parallel absorber show good results, it can reduce 77.98-80.62%, 60.34-69.95% and 54.39-69.81% of tremor amplitude at the shoulder, elbow and wrist joints, respectively.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 50 条
  • [32] TREMOR AND OTHER EXTRAPYRAMIDAL INVOLUNTARY MOVEMENT-DISORDERS
    MUMENTHALER, M
    THERAPEUTISCHE UMSCHAU, 1988, 45 (01) : 6 - 6
  • [33] Internet of thing-based hand tremor monitoring system and automated detection of hand tremor frequency
    Onder, Mithat
    Daldal, Nihat
    Polat, Kemal
    Dogan, Muhsin Ugur
    COMPUTERS & ELECTRICAL ENGINEERING, 2025, 122
  • [34] Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
    Zhou, Y.
    Jenkins, M. E.
    Naish, M. D.
    Trejos, A. L.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2018, 26 (09) : 1823 - 1834
  • [35] Focal task-specific hand tremor with using scissors
    Ma, H. -I.
    Kim, Y. J.
    Kim, B. -N.
    Kang, S. Y.
    Lee, B. -C.
    MOVEMENT DISORDERS, 2009, 24 : S510 - S510
  • [36] Designing controllers for hand tremor suppression using model simplification
    Chandra, Gauri
    Gandhi, Tapan K.
    Singh, Bhim
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2024, 96
  • [37] The Measurement and Analysis of Parkinsonian Hand Tremor
    Zhou, Y.
    Jenkins, M. E.
    Naish, M. D.
    Trejos, A. L.
    2016 3RD IEEE EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL AND HEALTH INFORMATICS, 2016, : 414 - 417
  • [38] ALCOHOL DRINKING REDUCES HAND TREMOR
    LANDAUER, AA
    BRITISH JOURNAL OF ADDICTION, 1981, 76 (04): : 429 - 430
  • [39] Insulin dependent diabetes and hand tremor
    Khachaturyan, S.
    Avagyan, G.
    Harutyunyan, K.
    Voskanyan, A.
    Gabrielyan, I.
    Amirjanyan, H.
    Manvelyan, H.
    MOVEMENT DISORDERS, 2016, 31 : S320 - S320
  • [40] Psychosocial Indicators via Hand Tremor
    Selker, Ted
    Collins, Patricia
    Dayton, Will
    HUMAN-COMPUTER INTERACTION - INTERACT 2011, PT IV, 2011, 6949 : 596 - 599