Tear osmolarity measurement using the TearLab™ Osmolarity System in the assessment of dry eye treatment effectiveness

被引:121
|
作者
Benelli, Umberto [1 ]
Nardi, Marco [1 ]
Posarelli, Chiara [1 ]
Albert, Timothy G. [1 ]
机构
[1] Univ Pisa, Dept Neurosci, Sect Ophthalmol, I-56126 Pisa, Pi, Italy
来源
CONTACT LENS & ANTERIOR EYE | 2010年 / 33卷 / 02期
关键词
Lubricant eye drop; Tear osmolarity; Dry eye; ARTIFICIAL TEARS; INSTILLATION; FORMULATIONS;
D O I
10.1016/j.clae.2010.01.003
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the efficacy of three commercially available lubricant eye drops for the treatment of mild, dry, irritated eyes. Methods: Randomized, investigator-masked evaluation of 60 patients in which 20 patients used carboxymethylcellulose sodium (CMC), 0.5% (Cellufresh (R), Allergan Inc., Irvine, CA) (group 1); 20 patients used a drop containing polyethylene glycol 400, 2.5% and sodium hyaluronate (Blink (R) Tears, Abbott Medical Optics Inc., Santa Ana, CA) (group 2); and 20 patients used HP Guar 0.18% (Systane (R), Alcon Laboratories Inc., Ft. Worth, TX) (group 3). Study visits were at baseline and 1 month. Tests performed at both visits included Schirmer, tear-film break-up time (TBUT), visual acuity, fluorescein staining, tear osmolarity and wavefront aberrometry. Osmolarity testing was performed prior to instillation of the lubricant eye drops and then a final time 5 min after instillation of the drop at both day 1 and day 30. Tear osmolarity was performed only in the right eye and only one time before and after instillation of lubricant eye drops. Results: At day 1 the mean reduction in osmolarity 5 min after instillation of the lubricant eye drop was, -5.0 +/- 1.9 in group 1, -9.0 +/- 4.2 in group 2 and -5.0 +/- 2.2 in group 3. At day 30 the mean reduction in osmolarity 5 min after instillation of the lubricant eye drop was, -5.6 +/- 2.3 mOsm/L in group 1; -9.9 +/- 2.8 mOsm/L in group 2 and -4.5 +/- 1.8 mOsm/L in group 3. The differences were statistically significant between groups 1 and 2, and 2 and 3. There was a reduction of osmolarity from day 1 to day 30 but the differences were not statistically significant. We feel that after a 30-day treatment with the lubricant eye drops, the lower osmolarity values could indicate that the tear film is progressing towards a more normal osmolarity value. A future study could examine the tear osmolarity value after 60 or 90 days of usage. LogMAR best-corrected visual acuity (BCVA) results showed an improvement in group 2 compared with baseline with no change in BCVA in groups 1 and 3. There was no statistically significant change from day 1 to 1 month in TBUT, while the Schirmer test showed an improvement in all groups at 1 month. Conclusions: Assessment of tear osmolarity provides the most objective, measurable test for determining improvement in dry eye patients. The instillation of any artificial tear or lubricant eye drop should decrease the tear-film osmolarity. The results found that polyethylene glycol 400,0.25% and sodium hyaluronate (Blink (R) Intensive Tears) significantly improved tear osmolarity compared with carboxymethylcellulose sodium (CMC), 0.5% (Cellufresh (R)) and HP Guar 0.18% (Systane (R)) after instillation. (C) 2010 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [41] Tear Osmolarity and Dry Eye Symptoms in Women Using Oral Contraception and Contact Lenses
    Chen, Sarah P.
    Massaro-Giordano, Giacomina
    Pistilli, Maxwell
    Schreiber, Courtney A.
    Bunya, Vatinee Y.
    CORNEA, 2013, 32 (04) : 423 - 428
  • [42] Diagnostic Performance of the Tear Meniscus Osmolarity Measurement for Dry Eye Disease in Rheumatoid Arthritis Patients
    De La Parra-Colin, Paola
    Palacios-Aguirre, Karen
    Perez-Pria-Kasusky, Andrea
    Espinosa-Morales, Rolando
    Hidalgo-Bravo, Alberto
    DIAGNOSTICS, 2023, 13 (18)
  • [43] Dry Eye in Rheumatoid Arthritis: Tear Film Osmolarity and Inflammation Reply
    Schargus, Marc
    Geerling, Gerd
    CORNEA, 2015, 34 (03) : E6 - E6
  • [44] Role of Tear Osmolarity in Dry Eye Symptoms After Cataract Surgery
    Gonzalez-Mesa, Ana
    Moreno-Arrones, Javier Paz
    Ferrari, Daniele
    Teus, Miguel A.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 170 : 128 - 132
  • [45] Progressively Increased Variation in Tear Osmolarity Mirrors Dry Eye Severity
    Sullivan, Benjamin D.
    Pepose, Jay S.
    Foulks, Gary N.
    JAMA OPHTHALMOLOGY, 2015, 133 (12) : 1481 - 1482
  • [46] Tear Film Osmolarity Measurements in Dry Eye Disease Using Electrical Impedance Technology
    Jacobi, Christina
    Jacobi, Arnd
    Kruse, Friedrich E.
    Cursiefen, Claus
    CORNEA, 2011, 30 (12) : 1289 - 1292
  • [47] Assessment of tear osmolarity and other dry eye parameters in cataract patients before and after surgery
    Sheng, Minjie
    Li, Bing
    Wang, Peng
    Liu, Hao
    Chen, Yihui
    Wang, Weifang
    Lin, Anjuan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [48] Analysis of basal and reflex human tear osmolarity in normal subjects: assessment of tear osmolarity
    Abusharha, Ali A.
    AlShehri, Tariq M.
    Hakami, Abdullah Y.
    Alsaqr, Ali M.
    Fagehi, Raied A.
    Alanazi, Saud A.
    Masmali, Ali M.
    THERAPEUTIC ADVANCES IN OPHTHALMOLOGY, 2018, 10
  • [49] Correlation with Schirmer test and break up time of tear osmolarity measurement in dry eye syndrome patients
    Yigit, Ulviye
    Kirik, Furkan
    Evcimen, Yusuf
    Agachan, Ahmet
    MEDICAL JOURNAL OF BAKIRKOY, 2013, 9 (02) : 73 - 77
  • [50] Progressively Increased Variation in Tear Osmolarity Mirrors Dry Eye Severity Reply
    Bunya, Vatinee Y.
    Pistilli, Maxwell
    Ying, Gui-Shuang
    JAMA OPHTHALMOLOGY, 2015, 133 (12) : 1482 - 1482